Coherent linear optical sampling at 15 bits of resolution
Abstract
Linear optical sampling characterizes a sample by measuring the distortions on a transmitted optical field, thereby quantifying the sample's optical response. By exploiting the high mutual coherence between two phase-locked femtosecond fiber lasers, we achieve very high signal-to-noise ratio measurements of transmitted optical electric fields through coherent averaging. We measure the optical electric fields with 15.16 bits of dynamic range (91 dB in intensity) and with 525 fs timing resolution over a 10 ns time window, in a 5.1 s averaging period.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A similar analytical procedure has been proposed to determine d in the terahertz frequency range, and this idea has been applied to the characterization of various materials.
“Note that a similar analytical procedure has been proposed to determine d in the terahertz frequency range 34,35 , and this idea has been applied to the characterization of various materials 36,37,38,39 .”
From Ultra-precise determination of thicknesses and refractive indices of optically thick dispersive materials by dual-comb spectroscopy (2022) · cites this paper as [34]
In the terahertz frequency range, the value of M is uniquely and easily determined by extrapolating Δφ(ω) to ω=0, where ΔΦ_abs should be always zero.
“However, in the terahertz frequency range, the value of M is uniquely and easily determined by extrapolating Δ ϕ ( ω ) to ω =0, where Δ Φ abs should be always zero.”
From Ultra-precise determination of thicknesses and refractive indices of optically thick dispersive materials by dual-comb spectroscopy (2022) · cites this paper as [34]
Cites
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,121 · see citing works
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059 · see citing works
Self-citationLepetit, L., Chériaux, G., & Joffre, M. (1995) · Journal of the Optical Society of America B · doi:10.1364/josab.12.002467 · Cited by 952 · see citing works
Coherent Multiheterodyne Spectroscopy Using Stabilized Optical Frequency Combs
Coddington, I. R., Swann, W. C., & Newbury, N. R. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.013902 · Cited by 821 · see citing works
Self-citationTime-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734 · see citing works
An Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J., Curtis, E. A., Drullinger, R. E., Hollberg, L. W., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720 · see citing works
Ultrafast time-domain spectroscopy based on high-speed asynchronous optical sampling
Bartels, A., Cerna, R., Kistner, C., Thoma, A., Hudert, F., Janke, C., & Dekorsy, T. (2007) · Review of Scientific Instruments · doi:10.1063/1.2714048 · Cited by 460 · see citing works
Spectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445 · see citing works
Frequency-comb infrared spectrometer for rapid, remote chemical sensing
Schließer, A., Brehm, M., Keilmann, F., & van der Weide, D. W. (2005) · Optics Express · doi:10.1364/opex.13.009029 · Cited by 383 · see citing works
Measurement of the intensity and phase of ultraweak, ultrashort laser pulses
Fittinghoff, D. N., Walmsley, I. A., Bowie, J. L., et al. (1996) · Optics Letters · doi:10.1364/ol.21.000884 · Cited by 227 · see citing works
The role of dispersion in ultrafast optics
Walmsley, I. A., Waxer, L. J., & Dorrer, C. (2001) · Review of Scientific Instruments · doi:10.1063/1.1330575 · Cited by 226 · see citing works
Yasui, T., Kabetani, Y., Saneyoshi, E., Yokoyama, S., & Araki, T. (2006) · Applied Physics Letters · doi:10.1063/1.2209718 · Cited by 223 · see citing works
Dorrer, C., Kilper, D. C., Stuart, H. R., Raybon, G., & Raymer, M. G. (2003) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2003.819729 · Cited by 149 · see citing works
Giaccari, P., Deschênes, J.-D., Saucier, P., Genest, J., & Tremblay, P. (2008) · Optics Express · doi:10.1364/oe.16.004347 · Cited by 128 · see citing works
Coddington, I. R., Swann, W. C., Lorini, L., Bergquist, J., Coq, Y. L., Oates, C. W., Quraishi, Q. S., Feder, K. S., Nicholson, J. W., Westbrook, P. S., et al. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.71 · Cited by 118 · see citing works
Self-citationFiber-laser frequency combs with subhertz relative linewidths
Swann, W. C., McFerran, J. J., Coddington, I. R., Newbury, N. R., Hartl, I., Fermann, M. E., Westbrook, P. S., Nicholson, J. W., Feder, K. S., Langrock, C., et al. (2006) · Optics Letters · doi:10.1364/ol.31.003046 · Cited by 115 · see citing works
Self-citationInfluence of the calibration of the detector on spectral interferometry
Dorrer, C. (1999) · Journal of the Optical Society of America B · doi:10.1364/josab.16.001160 · Cited by 95 · see citing works
Linear self-referencing techniques for short-optical-pulse characterization [Invited]
Dorrer, C., & Kang, I. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.0000a1 · Cited by 38 · see citing works
Williams, P. A., Dennis, T., Coddington, I. R., et al. (2008) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2008.2005787 · Cited by 21 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754 · see citing works
Self-citationCoherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322 · see citing works
Self-citationContinuous real-time correction and averaging for frequency comb interferometry
Roy, J., Deschênes, J.-D., Potvin, S., & Genest, J. (2012) · Optics Express · doi:10.1364/oe.20.021932 · Cited by 245 · see citing works
Ultra-broadband dual-comb spectroscopy across 1.0–1.9 µm
Okubo, S., Iwakuni, K., Inaba, H., Hosaka, K., Onae, A., Sasada, H., & Hong, F.-L. (2015) · Applied Physics Express · doi:10.7567/apex.8.082402 · Cited by 173 · see citing works
Sumihara, K. A., Okubo, S., Okano, M., Inaba, H., & Watanabe, S. (2022) · Optics Express · doi:10.1364/oe.445134 · Cited by 13 · see citing works
- Authors
- Coddington, I., Swann, W. C., & Newbury, N. R.
- Affiliations
- National Institute of Standards and Technology (US)
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2009-07-09
- Volume
- 34
- Issue
- 14
- Pages
- 2153
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2072480369
- Cited by
- 120
- References
- 19
- Citations by year
- 2026: 4 · 2025: 11 · 2024: 4 · 2023: 4 · 2022: 7 · 2021: 6 · 2020: 9 · 2019: 11 · 2018: 11 · 2017: 6 · 2016: 8 · 2015: 7 · 2014: 3 · 2013: 5 · 2012: 8
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Optics Letters (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Keywords
- linear optical sampling, coherent averaging, femtosecond fiber laser, phase-locked lasers, mutual coherence, high dynamic range, timing resolution, signal-to-noise ratio, ultrafast optics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review