Achromatic prism-type wave plate for broadband terahertz pulses
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We demonstrated achromatic half- and quarter-wave plates for broadband terahertz pulses using phase retardation by internal total reflection. Prism-type wave plates realized ultra-broadband retardation stability up to 2.5 THz, which was the limitation of our experimental setup. Novel aspects of our work were use of a 3λ/4 plate as a quarter-wave plate and a multistacked prism-type (MSP) wave plate for a large-aperture THz beam. Real-time polarization imaging of two crossed bunches of hairs was performed to show the efficiency of the MSP wave plate. We clearly observed polarization dependence of the hair direction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Dai, J., Zhang, J., Zhang, W., & Grischkowsky, D. (2004) · Journal of the Optical Society of America B · doi:10.1364/josab.21.001379 · Cited by 499
Cited by
Broadband tunable liquid crystal terahertz waveplates driven with porous graphene electrodes
Wang, L., Lin, X.-W., Hu, W., Shao, G.-H., Chen, P., Liang, L.-J., Jin, B.-B., Wu, P.-H., Qian, H., Lu, Y.-N., et al. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.26 · Cited by 183
Vacuum Bloch–Siegert shift in Landau polaritons with ultra-high cooperativity
Li, X., Bamba, M., Zhang, Q., Fallahi, S., Gardner, G. C., Gao, W., Lou, M., Yoshioka, K., Manfra, M. J., & Kono, J. (2018) · Nature Photonics · doi:10.1038/s41566-018-0153-0 · Cited by 158
“The THz wave incident onto the sample was right-hand circularly polarized (RCP) after passing through an achromatic quarter wave plate [4].”
MethodChang, C.-C., Zhao, Z., Li, D., Taylor, A. J., Fan, S., & Chen, H.-T. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.237401 · Cited by 131
Terahertz spectroscopy of anisotropic materials using beams with rotatable polarization
Mosley, C. D. W., Failla, M., Prabhakaran, D., & Lloyd-Hughes, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-12568-0 · Cited by 53
Carrier envelope phase shifter for broadband terahertz pulses
Kawada, Y., Yasuda, T., & Takahashi, H. (2016) · Optics Letters · doi:10.1364/ol.41.000986 · Cited by 30
Self-citation
Metadata
- Authors
- Kawada, Y., Yasuda, T., Nakanishi, A., Akiyama, K., Hakamata, K., & Takahashi, H.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2014-04-30
- Volume
- 39
- Issue
- 9
- Pages
- 2794
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2053312876
- Cited by
- 43
- References
- 2
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.