Abstract
Deep neural networks have emerged as effective tools for computational imaging, including quantitative phase microscopy of transparent samples. To reconstruct phase from intensity, current approaches rely on supervised learning with training examples; consequently, their performance is sensitive to a match of training and imaging settings. Here we propose a new approach to phase microscopy by using an untrained deep neural network for measurement formation, encapsulating the image prior and the system physics. Our approach does not require any training data and simultaneously reconstructs the phase and pupil-plane aberrations by fitting the weights of the network to the captured images. To demonstrate experimentally, we reconstruct quantitative phase from through-focus intensity images without knowledge of the aberrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596 · cited 2×
“ased procedure. Once the weights are optimized, the sought phase image is retrieved as the output of the deep decoder part of the network. of the problem. The approach is fundamental to phase imaging [12] and has been practically employed in various systems. An immediate advantage is that our prior assumptions on the…”
BackgroundMethodLempitsky, V., Vedaldi, A., & Ulyanov, D. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00984 · Cited by 1,916
Wide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829
Marquet, P., Rappaz, B., Magistretti, P. J., Cuche, E., Emery, Y., Colomb, T., & Depeursinge, C. (2005) · Optics Letters · doi:10.1364/ol.30.000468 · Cited by 1,254 · cited 1×
“Quantitative phase microscopy (QPM) enables label-free imaging of transparent samples such as unstained cells and tissues [1,2], and non-absorbing microelements [3].”
BackgroundPhase recovery and holographic image reconstruction using deep learning in neural networks
Rivenson, Y., Zhang, Y., Günaydın, H., Teng, D., & Ozcan, A. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.141 · Cited by 1,059 · cited 1×
“For phase microscopy, trained DNNs give state-of-the-art performance in holographic [18], lensless [19], ptychographic [20], and through-scattering-media [21, 22] configurations, among others [23].”
BackgroundPhase Retrieval via Wirtinger Flow: Theory and Algorithms
Candès, E. J., Li, X., & Soltanolkotabi, M. (2015) · IEEE Transactions on Information Theory · doi:10.1109/tit.2015.2399924 · Cited by 1,049 · cited 2×
“To compare against our method, we reconstruct reference phase images with the accelerated Wirtinger flow algorithm [33] using (5) for 8 and 4 (defocus of 4, 8, 16, and 32 μm) measurements.”
MethodSpatial light interference microscopy (SLIM)
Wang, Z., Millet, L. J., Mir, M., Ding, H., Unarunotai, S., Rogers, J. A., Gillette, M. U., & Popescu, G. (2011) · Optics Express · doi:10.1364/oe.19.001016 · Cited by 751 · cited 1×
“Examples include through-focus [5,6], interferometric [7,8], and angle-scanning [9,10] microscopes.”
BackgroundLensless computational imaging through deep learning
Sinha, A., Lee, J., Li, S., & Barbastathis, G. (2017) · Optica · doi:10.1364/optica.4.001117 · Cited by 703
Multiplexed coded illumination for Fourier Ptychography with an LED array microscope
Tian, L., Li, X., Ramchandran, K., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002376 · Cited by 584 · cited 1×
“of the objective and wavelength . Phase is recovered based on multiple images with some type of data diversity that translates phase information into intensity (e.g. defocus [5], illumination coding [31], pupil coding [32]). Here we adopt a pupil-coding scheme where the wavefront at the exit pupil [12] is dierently ab…”
MethodSelf-citationDeep speckle correlation: a deep learning approach toward scalable imaging through scattering media
Li, Y., Xue, Y., & Tian, L. (2018) · Optica · doi:10.1364/optica.5.001181 · Cited by 527 · cited 1×
“Although improved DNN architectures have been proposed [24–27], training-based approaches fundamentally rely on the reconstructed phase image to come from a distribution that is close to the one of the training images and are thus sensitive to misfits.”
Background
Cited by
Far-field super-resolution ghost imaging with a deep neural network constraint
Wang, F., Wang, C., Chen, M., Gong, W., Zhang, Y., Han, S., & Situ, G. (2022) · Light: Science & Applications · doi:10.1038/s41377-021-00680-w · Cited by 400
Self-citation
Metadata
- Authors
- Bostan, E., Heckel, R., Chen, M., Kellman, M., & Waller, L.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2020-05-21
- Volume
- 7
- Issue
- 6
- Pages
- 559
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W3003088017
- Cited by
- 189
- References
- 26
- FWCI
- 10.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep phase decoder: self-calibrating phase microscopy with an untrained deep neural network. https://app.cochat.ai/papers/10.1364/optica.389314
- The paper
- Bostan, E., Heckel, R., Chen, M., Kellman, M., & Waller, L. (2020). Deep phase decoder: self-calibrating phase microscopy with an untrained deep neural network. Optica. https://doi.org/10.1364/optica.389314
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.