Luminescence Lifetime Imaging of Oxygen, pH, and Carbon Dioxide Distribution Using Optical Sensors
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We present a modular system for time-resolved two-dimensional luminescence lifetime imaging of planar optical chemical sensors. It is based on a fast, gateable charge-coupled device (CCD) camera without image intensifier and a pulsable light-emitting diode (LED) array as a light source. Software was developed for data acquisition with a maximum of parameter variability and for background suppression. This approach allows the operation of the system even under daylight. Optical sensors showing analyte-specific changes of their luminescence decay time were tested and used for sensing pO 2, pCO 2, pH, and temperature. The luminophores employed are either platinum(II)-porphyrins or ruthenium(II)-polypyridyl complexes, contained in polymer films, and can be efficiently excited by blue LEDs. The decay times of the sensor films vary from 70 μs for the Pt(II)-porphyrins to several 100 ns for the Ru(II) complexes. In a typical application, 7 mm-diameter spots of the respective optical sensor films were placed at the bottom of the wells of microtiterplates. Thus, every well represents a separate calibration chamber with an integrated sensor element. Both luminescence intensity-based and time-resolved images of the sensor spots were evaluated and compared. The combination of optical sensor technology with time-resolved imaging allows a determination of the distribution of chemical or physical parameters in heterogeneous systems and is therefore a powerful tool for screening and mapping applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue
Rumsey, W., Vanderkooi, J., & Wilson, D. (1988) · Science · doi:10.1126/science.241.4873.1649 · Cited by 534
Bacon, J. R., & Demas, J. N. (1987) · Analytical Chemistry · doi:10.1021/ac00150a012 · Cited by 385
Glud, R. N., Ramsing, N., Gundersen, J. K., & Klimant, I. (1996) · Marine Ecology Progress Series · doi:10.3354/meps140217 · Cited by 289
Self-citationBallew, R. M., & Demas, J. N. (1989) · Analytical Chemistry · doi:10.1021/ac00176a007 · Cited by 262
Lifetime-selective fluorescence imaging using an rf phase-sensitive camera
Lakowicz, J. R., & Berndt, K. W. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142413 · Cited by 257
Sundfør, K., Lyng, H., & Rofstad, E. (1998) · British Journal of Cancer · doi:10.1038/bjc.1998.586 · Cited by 186
Transient digitizer for the determination of microsecond luminescence lifetimes
Woods, R. J., Scypinski, S., & Love, L. J. C. (1984) · Analytical Chemistry · doi:10.1021/ac00272a043 · Cited by 128
Localization of tumors and evaluation of their state of oxygenation by phosphorescence imaging.
Wilson, D. F., & Cerniglia, G. J. (1992) · PubMed · Cited by 101
Neurauter, G., Klimant, I., & Wolfbeis, O. S. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00748-x · Cited by 100
Self-citation2-D fluorescence lifetime imaging using a time-gated image intensifier
Dowling, K., Hyde, S. C. W., Dainty, J. C., French, P. M. W., & Hares, J. D. (1997) · Optics Communications · doi:10.1016/s0030-4018(96)00618-9 · Cited by 94
Cited by
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2006) · Analytical Chemistry · doi:10.1021/ac060490z · Cited by 1,627
Self-citationOptical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Self-citationOptical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Self-citationMaterials for fluorescence-based optical chemical sensors
Wolfbeis, O. S. (2005) · Journal of Materials Chemistry · doi:10.1039/b501536g · Cited by 486
Self-citationIndicators for optical oxygen sensors
Quaranta, M., Borisov, S. M., & Klimant, I. (2012) · Bioanalytical Reviews · doi:10.1007/s12566-012-0032-y · Cited by 452
Self-citationYersin, H. (2012) · Topics in Current Chemistry · doi:10.1007/b96858 · Cited by 449
Multiple fluorescent chemical sensing and imaging
Stich, M. I. J., Fischer, L. H., & Wolfbeis, O. S. (2010) · Chemical Society Reviews · doi:10.1039/b909635n · Cited by 341
Self-citationFiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2002) · Analytical Chemistry · doi:10.1021/ac020176e · Cited by 325
Self-citationMarx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“Miniaturized sensors based on thin-film or microbead-based fluorescent indicators (Liebsch et al., 2000; Schmälzlin et al., 2005) are increasingly implemented into MPS to monitor and control dO2, dCO2 or pH.”
Oxygen dynamics in permeable sediments with wave‐driven pore water exchange
Precht, E., Franke, U., Polerecky, L., & Huettel, M. (2004) · Limnology and Oceanography · doi:10.4319/lo.2004.49.3.0693 · Cited by 260
Luminescent sensing and imaging of oxygen: Fierce competition to the Clark electrode
Wolfbeis, O. S. (2015) · BioEssays · doi:10.1002/bies.201500002 · Cited by 252
Self-citationDetermination of oxygen gradients in engineered tissue using a fluorescent sensor
Kellner, K., Liebsch, G., Klimant, I., Wolfbeis, O. S., Blunk, T., Schulz, M. B., & Göpferich, A. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10352 · Cited by 238
Self-citationDual Fluorescence Sensor for Trace Oxygen and Temperature with Unmatched Range and Sensitivity
Baleizão, C., Nagl, S., Schäferling, M., Berberan-Santos, M. N., & Wolfbeis, O. S. (2008) · Analytical Chemistry · doi:10.1021/ac801034p · Cited by 236
Self-citationAdvanced imaging techniques for assessment of structure, composition and function in biofilm systems
Neu, T. R., Manz, B., Volke, F., Dynes, J. J., Hitchcock, A. P., & Lawrence, J. R. (2010) · FEMS Microbiology Ecology · doi:10.1111/j.1574-6941.2010.00837.x · Cited by 231
Two decades of chemical imaging of solutes in sediments and soils – a review
Santner, J., Larsen, M., Kreuzeder, A., & Glud, R. N. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.006 · Cited by 197
Light emitting diode-based detectors
Dasgupta, P. K., Eom, I.-Y., Morris, K. J., & Li, J. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00575-0 · Cited by 194
A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces
Stich, M. I. J., Nagl, S., Wolfbeis, O. S., Henne, U., & Schaeferling, M. (2008) · Advanced Functional Materials · doi:10.1002/adfm.200701199 · Cited by 175
Self-citationOptical Oxygen Sensors for Applications in Microfluidic Cell Culture
Grist, S. M., Chrostowski, L., & Cheung, K. C. (2010) · Sensors · doi:10.3390/s101009286 · Cited by 169
“This type of sensor has been quite widely used as un-patterned films [28,38,46,47,50,62,63,77,91,130].”
BackgroundMethodInfluentialThe luminescence properties of multinuclear platinum complexes
Puttock, E. V., Walden, M. T., & Williams, J. A. G. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.04.003 · Cited by 168
Application of microbioreactors in fermentation process development: a review
Schäpper, D., Alam, M. N. H. Z., Szita, N., Eliasson Lantz, A., & Gernaey, K. V. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2955-x · Cited by 160
Rivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Metadata
- Authors
- Liebsch, G., Klimant, I., Frank, B., Holst, G., & Wolfbeis, O. S.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2000-04
- Volume
- 54
- Issue
- 4
- Pages
- 548-559
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W1972256499
- Cited by
- 211
- References
- 15
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.