On-Line Fermentation Monitoring by Mid-Infrared Spectroscopy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new method for on-line monitoring of fermentations using mid-infrared (MIR) spectroscopy has been developed. The method has been used to predict the concentrations of glucose and ethanol during a baker's yeast fermentations. A completely automated flow system was employed as an interface between the bioprocess under study and the Fourier transform infrared (FT-IR) spectrometer, which was equipped with a flow cell housing a diamond attenuated total reflection (ATR) element. By using the automated flow system, experimental problems related to adherence of CO 2 bubbles to the ATR surface, as well as formation of biofilms on the ATR surface, could be efficiently eliminated. Gas bubbles were removed during sampling, and by using rinsing steps any biofilm could be removed from the ATR surface. In this way, constant measuring conditions could be guaranteed throughout prolonged fermentation times (∼8 h). As a reference method, high-performance liquid chromatography (HPLC) with refractive index detection was used. The recorded data from different fermentations were modeled by partial least-squares (PLS) regression comparing two different strategies for the calibration. On the one hand, calibration sets were constructed from spectra recorded from either synthetic standards or from samples drawn during fermentation. On the other hand, spectra from fermentation samples and synthetic standards were combined to form a calibration set. Differences in the kinetics of the studied fermentation processes used for calibration and prediction, as well as the precision of the HPLC reference method, were identified as the main chemometric sources of error. The optimal PLS regression method was obtained using the mixed calibration set of samples from fermentations and synthetic standards. The root mean square errors of prediction in this case were 0.267 and 0.336 g/L for glucose and ethanol concentration, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84
Cited by
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
“• ethanol [108] • glucose; lactate [110]”
Claßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
“…Analyte Method Source S. cerevisiae Cell density NIR Ge et al. (1994) S. cerevisiae Biomass NIR Kiviharju et al. (2007) S. cerevisiae Glucose MIR Mazarevica et al. (2004) Ethanol S. cerevisiae 1-Phenyl-1,2-propandion MIR Trevisan and Poppi (2008)…”
MethodInfluentialTwo-dimensional fluorescence spectroscopy: A novel approach for controlling fed-batch cultivations
Hantelmann, K., Kollecker, M., Hüll, D., Hitzmann, B., & Scheper, T. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.07.016 · Cited by 80
“In order to maintain oxidative growth, se eral approaches have been published to contro feed rate at a level below the critical value, bey which ethanol is produced and therefore the biom yield decreased.”
BackgroundMethodSensors in Disposable Bioreactors Status and Trends
Glindkamp, A., Riechers, D., Rehbock, C., Hitzmann, B., Scheper, T., & Reardon, K. F. (2009) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2009_10 · Cited by 65
Metadata
- Authors
- Mazarevica, G., Diewok, J., Baena, J. R., Rosenberg, E., & Lendl, B.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2004-07
- Volume
- 58
- Issue
- 7
- Pages
- 804-810
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2132835018
- Cited by
- 121
- References
- 1
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On-Line Fermentation Monitoring by Mid-Infrared Spectroscopy. https://app.cochat.ai/papers/10.1366/0003702041389229
- The paper
- Mazarevica, G., Diewok, J., Baena, J. R., Rosenberg, E., & Lendl, B. (2004). On-Line Fermentation Monitoring by Mid-Infrared Spectroscopy. Applied Spectroscopy. https://doi.org/10.1366/0003702041389229
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.