Subsurface Probing in Diffusely Scattering Media Using Spatially Offset Raman Spectroscopy
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We describe a simple methodology for the effective retrieval of Raman spectra of subsurface layers in diffusely scattering media. The technique is based on the collection of Raman scattered light from surface regions that are laterally offset away from the excitation laser spot on the sample. The Raman spectra obtained in this way exhibit a variation in relative spectral intensities of the surface and subsurface layers of the sample being investigated. The data set is processed using a multivariate data analysis to yield pure Raman spectra of the individual sample layers, providing a method for the effective elimination of surface Raman scatter. The methodology is applicable to the retrieval of pure Raman spectra from depths well in excess of those accessible with conventional confocal microscopy. In this first feasibility study we have differentiated between surface and subsurface Raman signals within a diffusely scattering sample composed of two layers: trans-stilbene powder beneath a 1 mm thick over-layer of PMMA (poly(methyl methacrylate)) powder. The improvement in contrast of the subsurface trans-stilbene layer without numerical processing was 19 times. The potential applications include biomedical subsurface probing of specific tissues through different overlying tissues such as assessment of bone quality through skin, providing an effective noninvasive means of screening for bone degeneration, other skeletal disease diagnosis, and dermatology studies, as well as materials and catalyst research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Optics: Light Scattering Methods and Instruments for Medical Diagnosis
Tuchin, V. V. (2015) · SPIE eBooks · doi:10.1117/3.1003040 · Cited by 1,352
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Application of vibrational spectroscopy to the study of mineralized tissues (review)
Carden, A., & Morris, M. D. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429994 · Cited by 431
Self-citationEfficient Rejection of Fluorescence from Raman Spectra Using Picosecond Kerr Gating
Matousek, P., Towrie, M., Stanley, A., & Parker, A. W. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945993 · Cited by 235
Self-citationMatousek, P., Towrie, M., Ma, C., Kwok, W. M., Phillips, D., Toner, W. T., & Parker, A. W. (2001) · Journal of Raman Spectroscopy · doi:10.1002/jrs.784 · Cited by 172
Self-citationHigher-Order Brain Function Analysis by Trans-Cranial Dynamic Near-Infrared Spectroscopy Imaging
Koizumi, H., Yamashita, Y., Maki, A., Yamamoto, T., Ito, Y., Itagaki, H., & Kennan, R. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429959 · Cited by 164
Chew, W., Widjaja, E., & Garland, M. (2002) · Organometallics · doi:10.1021/om0108752 · Cited by 164
Widjaja, E., Li, C., Chew, W., & Garland, M. (2003) · Analytical Chemistry · doi:10.1021/ac0263622 · Cited by 152
Widjaja, E., Li, C., & Garland, M. (2002) · Organometallics · doi:10.1021/om010933j · Cited by 135
Everall, N. J., Hahn, T., Matousek, P., Parker, A. W., & Towrie, M. (2001) · Applied Spectroscopy · doi:10.1366/0003702011954053 · Cited by 126
Self-citation
Cited by
Vibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Kong, K., Kendall, C., Stone, N., & Notingher, I. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.009 · Cited by 653
Crocombe, R. A. (2018) · Applied Spectroscopy · doi:10.1177/0003702818809719 · Cited by 532
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Surface-enhanced Raman spectroscopy: a half-century historical perspective
Yi, J., You, E.-M., Hu, R., Wu, D.-Y., Liu, G.-K., Yang, Z.-L., Zhang, H., Gu, Y., Wang, Y.-H., Wang, X., et al. (2025) · Chemical Society Reviews · doi:10.1039/d4cs00883a · Cited by 382
Guo, S., Popp, J., & Bocklitz, T. (2021) · Nature Protocols · doi:10.1038/s41596-021-00620-3 · Cited by 361
“Special techniques like spatially offset Raman spectroscopy can be applied for larger penetration depth if necessary 31 .”
BackgroundContributions of Raman spectroscopy to the understanding of bone strength
Mandair, G. S., & Morris, M. D. (2015) · BoneKEy Reports · doi:10.1038/bonekey.2014.115 · Cited by 358
Self-citationClinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Challenges in application of Raman spectroscopy to biology and materials
Kuhar, N., Sil, S., Verma, T., & Umapathy, S. (2018) · RSC Advances · doi:10.1039/c8ra04491k · Cited by 334
Raman spectroscopy in pharmaceutical product design
Paudel, A., Raijada, D., & Rantanen, J. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.04.003 · Cited by 302
Vibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Surface-enhanced Raman spectroscopy: bottlenecks and future directions
Panneerselvam, R., Liu, G.-K., Wang, Y.-H., Liu, J.-Y., Ding, S.-Y., Li, J.-F., Wu, D.-Y., & Tian, Z.-Q. (2018) · Chemical Communications · doi:10.1039/c7cc05979e · Cited by 271
Bone tissue compositional differences in women with and without osteoporotic fracture
McCreadie, B. R., Morris, M. D., Chen, T.-C., Sudhaker Rao, D., Finney, W. F., Widjaja, E., & Goldstein, S. A. (2006) · Bone · doi:10.1016/j.bone.2006.06.008 · Cited by 253
Self-citationEllis, D. I., Muhamadali, H., Haughey, S. A., Elliott, C. T., & Goodacre, R. (2015) · Analytical Methods · doi:10.1039/c5ay02048d · Cited by 233
Noninvasive Raman Spectroscopy of Human Tissue in vivo
Matousek, P., Draper, E. R. C., Goodship, A. E., Clark, I. P., Ronayne, K. L., & Parker, A. W. (2006) · Applied Spectroscopy · doi:10.1366/000370206777886955 · Cited by 219
Self-citationIn vivo nonmelanoma skin cancer diagnosis using Raman microspectroscopy
Lieber, C. A., Majumder, S. K., Ellis, D. L., Billheimer, D. D., & Mahadevan‐Jansen, A. (2008) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20653 · Cited by 218
“One possible hypothesis for the diagnostic success despite out-ofvolume measurements is that the high degree of scattering and refractive mismatches encountered in vivo cause broadening of the tightly focused light impingent on the tissue, thus the actual measurement volume encountered in vivo was actually larger than…”
Diagnostic applications of Raman spectroscopy
Tu, Q., & Chang, C. (2012) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2011.09.013 · Cited by 217
“which the Raman scattered light was collected with a spatial offset from the point of laser incidence.(77,78) In another recent study, Qian and co-workers demonstrated in vivo tumor detection using SERS with PEGylated gold nanoparticles.”
Tabish, T. A., Dey, P., Mosca, S., Salimi, M., Palombo, F., Matousek, P., & Stone, N. (2020) · Advanced Science · doi:10.1002/advs.201903441 · Cited by 211
Self-citationRecent Developments in the Field of Explosive Trace Detection
To, K. C., Ben-Jaber, S., & Parkin, I. P. (2020) · ACS Nano · doi:10.1021/acsnano.0c01579 · Cited by 206
A new method using Raman spectroscopy for in vivo targeted brain cancer tissue biopsy
Desroches, J., Jermyn, M., Pinto, M., Picot, F., Tremblay, M.-A., Obaid, S., Marple, E., Urmey, K., Trudel, D., Soulez, G., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-20233-3 · Cited by 203
Raman spectroscopy in forensic analysis: identification of cocaine and other illegal drugs of abuse
de Oliveira Penido, C. A. F., Pacheco, M. T. T., Lednev, I. K., & Silveira, L. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4864 · Cited by 201
In-vivo Raman spectroscopy: from basics to applications
Cordero, E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.7.071210 · Cited by 195
“The concept behind SORS is that there is a spatial separation between the point of laser illumination and the point of Raman signal collection on the sample surface.(84,85) There are two main categories: SORS with a central illumination point and a collection ring and inverse-SORS with an illumination ring and a centr…”
BackgroundMethodInfluentialStone, N., Baker, R., Rogers, K., Parker, A. W., & Matousek, P. (2007) · The Analyst · doi:10.1039/b705029a · Cited by 195
Self-citationStewart, S., Priore, R. J., Nelson, M. P., & Treado, P. J. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143152 · Cited by 184
“(59, 60), SORS was introduced as a means for retrieving Raman spectra of subsurface layers in”
MethodSurface enhanced spatially offset Raman spectroscopic (SESORS) imaging – the next dimension
Stone, N., Kerssens, M., Lloyd, G. R., Faulds, K., Graham, D., & Matousek, P. (2011) · Chemical Science · doi:10.1039/c0sc00570c · Cited by 183
Self-citationYuen, J. M., Shah, N. C., Walsh, J. T., Glucksberg, M. R., & Van Duyne, R. P. (2010) · Analytical Chemistry · doi:10.1021/ac101951j · Cited by 183
Recent advances in the development of Raman spectroscopy for deep non‐invasive medical diagnosis
Matousek, P., & Stone, N. (2013) · Journal of Biophotonics · doi:10.1002/jbio.201200141 · Cited by 164
Self-citationIn Vitro and In Vivo SERS Biosensing for Disease Diagnosis
Moore, T. J., Moody, A. S., Payne, T. D., Sarabia, G. M., Daniel, A. R., & Sharma, B. (2018) · Biosensors · doi:10.3390/bios8020046 · Cited by 161
“SORS takes advantage of the spatial component of light where the Raman spectra are collected at a point that is spatially offset from the incident illumination point [54].”
BackgroundApplications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160
Nicolson, F., Andreiuk, B., Andreou, C., Hsu, H.-T., Rudder, S., & Kircher, M. F. (2019) · Theranostics · doi:10.7150/thno.36321 · Cited by 152
“, 'spatially offset Raman spectroscopy' (SORS) aims to overcome the depth limitations associated with conventional Raman spectroscopy [32].”
BackgroundCancer imaging using surface-enhanced resonance Raman scattering nanoparticles
Harmsen, S., Wall, M. A., Huang, R., & Kircher, M. F. (2017) · Nature Protocols · doi:10.1038/nprot.2017.031 · Cited by 146
Stone, N., Faulds, K., Graham, D., & Matousek, P. (2010) · Analytical Chemistry · doi:10.1021/ac100039c · Cited by 140
Self-citationSurface Enhanced Spatially Offset Raman Spectroscopy Detection of Neurochemicals Through the Skull
Moody, A. S., Baghernejad, P. C., Webb, K. R., & Sharma, B. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00985 · Cited by 56
Zhang, Y., Chen, R., Liu, F., Miao, P., Lin, L., & Ye, J. (2023) · Small Methods · doi:10.1002/smtd.202201334 · Cited by 52
Clegg, I. (2020) · Specification of Drug Substances and Products · doi:10.1016/b978-0-08-102824-7.00007-5 · Cited by 14
Metadata
- Authors
- Matousek, P., Clark, I. P., Draper, E. R. C., Morris, M. D., Goodship, A. E., Everall, N., Towrie, M., Finney, W. F., & Parker, A. W.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2005-04
- Volume
- 59
- Issue
- 4
- Pages
- 393-400
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2021448456
- Cited by
- 548
- References
- 13
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.