Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
A significant advantage of Raman spectroscopy as a noninvasive optical technique is its ability to detect subtle molecular or biochemical signatures within tissue. One of the major challenges for biomedical Raman spectroscopy is the removal of intrinsic autofluorescence background signals, which are usually a few orders of magnitude stronger than those arising from Raman scattering. A number of methods have been proposed for fluorescence background removal including excitation wavelength shifting, Fourier transformation, time gating, and simple or modified polynomial fitting. The single polynomial and the modified multi-polynomial fitting methods are relatively simple and effective, and thus are widely used in biological applications. However, their performance in real-time in vivo applications and low signal-to-noise ratio environments is sub-optimal. An improved automated algorithm for fluorescence removal has been developed based on modified multi-polynomial fitting, but with the addition of (1) a peak-removal procedure during the first iteration, and (2) a statistical method to account for signal noise effects. Experimental results demonstrate that this approach improves the automated rejection of the fluorescence background during real-time Raman spectroscopy and for in vivo measurements characterized by low signal-to-noise ratios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Automated Method for Subtraction of Fluorescence from Biological Raman Spectra
Lieber, C. A., & Mahadevan-Jansen, A. (2003) · Applied Spectroscopy · doi:10.1366/000370203322554518 · Cited by 1,049
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Self-citationRaman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Combined In Vivo Confocal Raman Spectroscopy and Confocal Microscopy of Human Skin
Caspers, P. J., Lucassen, G. W., & Puppels, G. J. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74501-9 · Cited by 446
Investigation of Selected Baseline Removal Techniques as Candidates for Automated Implementation
Schulze, G., Jirasek, A., Yu, M. M. L., Lim, A., Turner, R. F. B., & Blades, M. W. (2005) · Applied Spectroscopy · doi:10.1366/0003702053945985 · Cited by 315
In vitro andin vivo Raman spectroscopy of human skin
Caspers, P. J., Lucassen, G. W., Wolthuis, R., Bruining, H. A., & Puppels, G. J. (1998) · Biospectroscopy · doi:10.1002/(sici)1520-6343(1998)4:5+<s31::aid-bspy4>3.0.co;2-m · Cited by 314
Shreve, A. P., Cherepy, N. J., & Mathies, R. A. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125122 · Cited by 312
Raman spectroscopy for noninvasive glucose measurements
Enejder, A. M. K., Scecina, T. G., Oh, J., Hunter, M., Shih, W.-C., Sasic, S., Horowitz, G. L., & Feld, M. S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1920212 · Cited by 271
Cited by
Baseline correction using adaptive iteratively reweighted penalized least squares
Zhang, Z.-M., Chen, S., & Liang, Y.-Z. (2010) · The Analyst · doi:10.1039/b922045c · Cited by 1,124
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Intraoperative brain cancer detection with Raman spectroscopy in humans
Jermyn, M., Mok, K., Mercier, J., Desroches, J., Pichette, J., Saint-Arnaud, K., Bernstein, L., Guiot, M.-C., Petrecca, K., & Leblond, F. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2384 · Cited by 618
Microplastic Spectral Classification Needs an Open Source Community: Open Specy to the Rescue!
Cowger, W., Steinmetz, Z., Gray, A., Munno, K., Lynch, J., Hapich, H., Primpke, S., De Frond, H., Rochman, C., & Herodotou, O. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c00123 · Cited by 569
Feng, S., Chen, R., Lin, J., Pan, J., Chen, G., Li, Y., Cheng, M., Huang, Z., Chen, J., & Zeng, H. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.03.033 · Cited by 450
Self-citationSpectral pre-processing for biomedical vibrational spectroscopy and microspectroscopic imaging
Lasch, P. (2012) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2012.03.011 · Cited by 353
Clinical instrumentation and applications of Raman spectroscopy
Pence, I., & Mahadevan-Jansen, A. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00581g · Cited by 352
Review of Fluorescence Suppression Techniques in Raman Spectroscopy
Wei, D., Chen, S., & Liu, Q. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.999936 · Cited by 334
An intelligent background‐correction algorithm for highly fluorescent samples in Raman spectroscopy
Zhang, Z., Chen, S., Liang, Y., Liu, Z., Zhang, Q., Ding, L., Ye, F., & Zhou, H. (2010) · Journal of Raman Spectroscopy · doi:10.1002/jrs.2500 · Cited by 308
Deep Learning for Raman Spectroscopy: A Review
Luo, R., Popp, J., & Bocklitz, T. (2022) · Analytica · doi:10.3390/analytica3030020 · Cited by 244
“Different pre-processing methods exist, such as traditional pre-processing, e.g., the Vancouver Raman algorithm [11], as well as machine learning options, such as automatic Raman spectra correction [12].”
Direct observation of glucose fingerprint using in vivo Raman spectroscopy
Kang, J. W., Park, Y. S., Chang, H., Lee, W., Singh, S. P., Choi, W., Galindo, L. H., Dasari, R. R., Nam, S. H., Park, J., et al. (2020) · Science Advances · doi:10.1126/sciadv.aay5206 · Cited by 232
“The analysis in this study was based on either background-removed spectra in the range of 810 to 1650 cm−1 by polynomial baseline subtraction (39) or band area features.”
Feng, S., Chen, R., Lin, J., Pan, J., Wu, Y., Li, Y., Chen, J., & Zeng, H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.020 · Cited by 224
“The fluorescence background of the original SERS data was firstly removed using a modified multi-polynomial fitting algorithm (Zhao et al., 2007), then each spectrum was normalized to the integrated area under the curve in the range from 460 to 1730 cm−1 before further processing.”
MethodSelf-citationA new method using Raman spectroscopy for in vivo targeted brain cancer tissue biopsy
Desroches, J., Jermyn, M., Pinto, M., Picot, F., Tremblay, M.-A., Obaid, S., Marple, E., Urmey, K., Trudel, D., Soulez, G., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-20233-3 · Cited by 203
A review on spectral data preprocessing techniques for machine learning and quantitative analysis
Yan, C. (2025) · iScience · doi:10.1016/j.isci.2025.112759 · Cited by 193
“Reweighted PLS (arPLS): Logistic sigmoid weighting ( w ti ) dynamically suppresses negative residuals (noise) while preserving peaks (Equation 43).”
Feng, S., Lin, D., Lin, J., Li, B., Huang, Z., Chen, G., Zhang, W., Wang, L., Pan, J., Chen, R., et al. (2013) · The Analyst · doi:10.1039/c3an36890d · Cited by 185
Self-citationRaman technologies in cancer diagnostics
Austin, L. A., Osseiran, S., & Evans, C. L. (2016) · The Analyst · doi:10.1039/c5an01786f · Cited by 182
Raman spectroscopy for cancer detection and cancer surgery guidance: translation to the clinics
Santos, I. P., Barroso, E. M., Bakker Schut, T. C., Caspers, P. J., van Lanschot, C. G. F., Choi, D.-H., van der Kamp, M. F., Smits, R. W. H., van Doorn, R., Verdijk, R. M., et al. (2017) · The Analyst · doi:10.1039/c7an00957g · Cited by 169
Zobkov, M. B., Esiukova, E. E., Zyubin, A. Y., & Samusev, I. G. (2019) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2018.11.047 · Cited by 164
Raman microspectroscopy for microbiology
Lee, K. S., Landry, Z., Pereira, F. C., Wagner, M., Berry, D., Huang, W. E., Taylor, G. T., Kneipp, J., Popp, J., Zhang, M., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00075-6 · Cited by 161
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
“accumulation of cells or cellular metabolism components within the system; however, the exact identity of compounds responsible for this is currently unknown to the authors.(37,38)”
BackgroundFull range characterization of the Raman spectra of organs in a murine model
Huang, N., Short, M., Zhao, J., Wang, H., Lui, H., Korbelik, M., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.022892 · Cited by 131
Self-citationYu, Y., Lin, Y., Xu, C., Lin, K., Ye, Q., Wang, X., Xie, S., Chen, R., & Lin, J. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.006053 · Cited by 79
Novel method to analyze post-yield mechanical properties at trabecular bone tissue level
Carretta, R., Luisier, B., Bernoulli, D., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.12.003 · Cited by 43
A Hybrid Least Squares and Principal Component Analysis Algorithm for Raman Spectroscopy
Van de Sompel, D., Garai, E., Zavaleta, C., & Gambhir, S. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0038850 · Cited by 39
Li, S. X., Zhang, Y. J., Zeng, Q. Y., Li, L. F., Guo, Z. Y., Liu, Z. M., Xiong, H. L., & Liu, S. H. (2014) · Laser Physics Letters · doi:10.1088/1612-2011/11/6/065603 · Cited by 38
Tension Causes Unfolding of Intracellular Vimentin Intermediate Filaments
Fleissner, F., Kumar, S., Klein, N., Wirth, D., Dhiman, R., Schneider, D., Bonn, M., & Parekh, S. H. (2020) · Advanced Biosystems · doi:10.1002/adbi.202000111 · Cited by 16
Tension causes structural unfolding of intracellular intermediate filaments
Fleissner, F., Kumar, S., Klein, N., Wirth, D., Dhiman, R., Schneider, D., Bonn, M., & Parekh, S. H. (2020) · doi:10.1101/2020.04.22.054379 · Cited by 16
Carretta, R., Stüssi, E., Müller, R., & Lorenzetti, S. (2015) · BioMed Research International · doi:10.1155/2015/457371 · Cited by 14
Metadata
- Authors
- Zhao, J., Lui, H., McLean, D. I., & Zeng, H.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2007-11
- Volume
- 61
- Issue
- 11
- Pages
- 1225-1232
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2091998550
- Cited by
- 810
- References
- 25
- FWCI
- 5.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.