Effective Rejection of Fluorescence Interference in Raman Spectroscopy Using a Shifted Excitation Difference Technique
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Resonance Raman spectroscopy is a powerful technique for probing the vibrations of particular chromophores in multicomponent systems. By tuning the wavelength of the excitation laser into resonance with an electronic absorption band of only one molecular species, the vibrational Raman scattering from this species can be selectively enhanced. Thus, resonance Raman spectroscopy can provide structural information for chromophores in solution or biological chromophores within their functionally active protein environment. However, since the very nature of the experiment requires that the excitation light be absorbed by the sample, the measurement of resonance Raman spectra is often made difficult by a large fluorescence background in the same spectral region as the Raman scattering. The problem of fluorescence interference from intrinsic sample emission is often further exacerbated in biological samples, where low-concentration impurities with large fluorescence yields can be difficult to remove. Even weak fluorescence, with an effective fluorescence quantum yield of ≈10−4, completely overwhelms resonance Raman signals, which have typical quantum yields of ≈10−7.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FT-Raman Spectroscopy: Development and Justification
Hirschfeld, T., & Chase, B. (1986) · Applied Spectroscopy · doi:10.1366/0003702864509538 · Cited by 393
Duyne, R. P. V., Jeanmaire, D. L., & Shriver, D. F. (1974) · Analytical Chemistry · doi:10.1021/ac60338a012 · Cited by 141
Sub-nanosecond time-resolved rejection of fluorescence from Raman spectra
Harris, J. M., Chrisman, R. W., Lytle, F. E., & Tobias, R. S. (1976) · Analytical Chemistry · doi:10.1021/ac50007a033 · Cited by 76
Rapid-flow resonance Raman spectroscopy of bacterial photosynthetic reaction centers.
Shreve, A. P., Cherepy, N. J., Franzen, S., Boxer, S. G., & Mathies, R. A. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.24.11207 · Cited by 72
Self-citationMeasurements of Spontaneous Raman Scattering with Nd:YAG 1064-nm Laser Light
Fujiwara, M., Hamaguchi, H., & Tasumi, M. (1986) · Applied Spectroscopy · doi:10.1366/0003702864509501 · Cited by 59
Fluorescence suppression in time-resolved Raman spectra
Burgess, S., & Shepherd, I. W. (1977) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/10/6/015 · Cited by 35
Fluorescence rejection in Raman spectroscopy using a gated intensified diode array detector
Everall, N. J., Jackson, R. W., Howard, J. A. K., & Hutchinson, K. (1986) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250170507 · Cited by 33
Howard, J. A. K., Everall, N. J., Jackson, R. W., & Hutchinson, K. (1986) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/19/11/013 · Cited by 28
Cited by
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Prospects for in vivo Raman spectroscopy
Hanlon, E. B., Manoharan, R., Koo, T.-W., Shafer, K. E., Motz, J. T., Fitzmaurice, M., Kramer, J. R., Itzkan, I., Dasari, R. R., & Feld, M. S. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/2/201 · Cited by 894
Automated Autofluorescence Background Subtraction Algorithm for Biomedical Raman Spectroscopy
Zhao, J., Lui, H., McLean, D. I., & Zeng, H. (2007) · Applied Spectroscopy · doi:10.1366/000370207782597003 · Cited by 810
Crocombe, R. A. (2018) · Applied Spectroscopy · doi:10.1177/0003702818809719 · Cited by 532
Metadata
- Authors
- Shreve, A. P., Cherepy, N. J., & Mathies, R. A.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1992-04
- Volume
- 46
- Issue
- 4
- Pages
- 707-711
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W1974361280
- Cited by
- 312
- References
- 8
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.