A Novel Approach to Office Blood Pressure Measurement: 30-Minute Office Blood Pressure vs Daytime Ambulatory Blood Pressure
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE: Current office blood pressure measurement (OBPM) is often not executed according to guidelines and cannot prevent the white-coat effect. Serial, automated, oscillometric OBPM has the potential to overcome both these problems. We therefore developed a 30-minute OBPM method that we compared with daytime ambulatory blood pressure. METHODS: Patients referred to a primary care diagnostic center for 24-hour ambulatory blood pressure monitoring (ABPM) had their blood pressure measured using the same validated ABPM device for both ABPM and 30-minute OBPMs. During 30-minute OBPM, blood pressure was measured automatically every 5 minutes with the patient sitting alone in a quiet room. The mean 30-minute OBPM (based on t = 5 to t = 30 minutes) was compared with mean daytime ABPM using paired t tests and the approach described by Bland and Altman on method comparison. RESULTS: We analyzed data from 84 patients (mean age 57 years; 61% female). Systolic and diastolic blood pressures differed from 0 to 2 mm Hg (95% confidence interval, -2 to 2 mm Hg and from 0 to 3 mm Hg) between mean 30-minute OBPM and daytime ABPM, respectively. The limits of agreement were between -19 and 19 mm Hg for systolic and -10 and 13 mm Hg for diastolic blood pressures. Both 30-minute OBPM and daytime ABPM classified normotension, white-coat hypertension, masked hypertension, and sustained hypertension equally. CONCLUSIONS: The 30-minute OBPM appears to agree well with daytime ABPM and has the potential to detect white-coat and masked hypertension. This finding makes 30-minute OBPM a promising new method to determine blood pressure during diagnosis and follow-up of patients with elevated blood pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Estimation of ten-year risk of fatal cardiovascular disease in Europe: the SCORE project
Conroy, R. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00114-3 · Cited by 5,290
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Stergiou, G. S., Baibas, N. M., Gantzarou, A. P., Skeva, I. I., Kalkana, C. B., Roussias, L. G., & Mountokalakis, T. D. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02324-x · Cited by 268
Cited by
Chronically implanted pressure sensors: challenges and state of the field
Yu, L., Kim, B., & Meng, E. (2014) · Sensors · doi:10.3390/s141120620 · Cited by 200
Reflection on modern methods: five myths about measurement error in epidemiological research
van Smeden, M., Lash, T. L., & Groenwold, R. H. H. (2020) · International Journal of Epidemiology · doi:10.1093/ije/dyz251 · Cited by 173
Random measurement error: Why worry? An example of cardiovascular risk factors
Brakenhoff, T. B., van Smeden, M., Visseren, F. L. J., & Groenwold, R. H. H. (2018) · PLOS ONE · doi:10.1371/journal.pone.0192298 · Cited by 52
Metadata
- Authors
- van der Wel, M. C., Buunk, I. E., van Weel, C., Thien, T. A. B. M., & Bakx, J. C.
- Venue
- The Annals of Family Medicine
- Publisher
- Annals of Family Medicine
- Published
- 2011-03-01
- Volume
- 9
- Issue
- 2
- Pages
- 128-135
- ISSN
- 1544-1709 (ISSN-L)
- 1544-1717
- OpenAlex
- W2124609167
- Cited by
- 66
- References
- 6
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.