CoChat

Regression Analysis for Constraining Free Parameters in Electrophysiological Models of Cardiac Cells

Open access
Sarkar, Amrita X., Sobie, Eric A. · 2010 · PLoS Computational Biology
Cited by 141

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

A major challenge in computational biology is constraining free parameters in mathematical models. Adjusting a parameter to make a given model output more realistic sometimes has unexpected and undesirable effects on other model behaviors. Here, we extend a regression-based method for parameter sensitivity analysis and show that a straightforward procedure can uniquely define most ionic conductances in a well-known model of the human ventricular myocyte. The model's parameter sensitivity was analyzed by randomizing ionic conductances, running repeated simulations to measure physiological outputs, then collecting the randomized parameters and simulation results as "input" and "output" matrices, respectively. Multivariable regression derived a matrix whose elements indicate how changes in conductances influence model outputs. We show here that if the number of linearly-independent outputs equals the number of inputs, the regression matrix can be inverted. This is significant, because it implies that the inverted matrix can specify the ionic conductances that are required to generate a particular combination of model outputs. Applying this idea to the myocyte model tested, we found that most ionic conductances could be specified with precision (R(2) > 0.77 for 12 out of 16 parameters). We also applied this method to a test case of changes in electrophysiology caused by heart failure and found that changes in most parameters could be well predicted. We complemented our findings using a Bayesian approach to demonstrate that model parameters cannot be specified using limited outputs, but they can be successfully constrained if multiple outputs are considered. Our results place on a solid mathematical footing the intuition-based procedure simultaneously matching a model's output to several data sets. More generally, this method shows promise as a tool to define model parameters, in electrophysiology and in other biological fields.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pcbi.1000914

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 141

Metadata

Authors
Sarkar, A. X., & Sobie, E. A.
Venue
PLoS Computational Biology
Published
2010-09-02
Volume
6
Issue
9
Pages
e1000914
ISSN
  • 1553-734X (ISSN-L)
  • 1553-7358
OpenAlex
W2075402097
Cited by
141
References
7
FWCI
6.13
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Regression Analysis for Constraining Free Parameters in Electrophysiological Models of Cardiac Cells. https://app.cochat.ai/papers/10.1371/journal.pcbi.1000914
The paper
Sarkar, A. X., & Sobie, E. A. (2010). Regression Analysis for Constraining Free Parameters in Electrophysiological Models of Cardiac Cells. PLoS Computational Biology. https://doi.org/10.1371/journal.pcbi.1000914

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.