Real-Time Fluorescence Loop Mediated Isothermal Amplification for the Diagnosis of Malaria
Open accessAbstract
BACKGROUND: Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. METHODOLOGY AND SIGNIFICANT FINDINGS: Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. CONCLUSION: This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Several studies reported high sensitivity and specificity of LAMP compared with microscopy or PCR in nonpregnant populations.
“Several studies that compared the LAMP method to microscopy, PCR and RDT, reported high sensitivity and specificity compared with microscopy or PCR in nonpregnant populations [34–37].”
From Diagnosing malaria in pregnancy: An update (2012) · cites this paper as [36]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805 · see citing works
Weltgesundheitsorganisation (2005) · Cited by 3,799 · see citing works
Accelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,049 · see citing works
Plasmodium knowlesi Malaria in Humans Is Widely Distributed and Potentially Life Threatening
Cox‐Singh, J., Davis, T. M. E., Lee, K.-S., Shamsul, S. S., Matusop, A., Ratnam, S., Rahman, H., Conway, D. J., & Singh, B. B. (2007) · Clinical Infectious Diseases · doi:10.1086/524888 · Cited by 884 · see citing works
Singh, B. B., Bobogare, A., Cox‐Singh, J., Snounou, G., Abdullah, M. S., & Rahman, H. (1999) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.1999.60.687 · Cited by 593 · see citing works
Gamboa, D., Ho, M., Bendezú, J., Torres, K., Chiodini, P. L., Barnwell, J. W., Incardona, S., Perkins, M. D., Bell, D., McCarthy, J. S., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008091 · Cited by 547 · see citing works
Self-citationPoon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476 · see citing works
Parida, M., Posadas-Herrera, G., Inoue, S., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.1.257-263.2004 · Cited by 439 · see citing works
Thai, H. T. C., Le, M. Q., Vuong, C. D., Parida, M., Minekawa, H., Notomi, T., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.1956-1961.2004 · Cited by 423 · see citing works
Han, E., Watanabe, R., Sattabongkot, J., Khuntirat, B., Sirichaisinthop, J., Iriko, H., Jin, L., Takeo, S., & Tsuboi, T. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02117-06 · Cited by 277 · see citing works
Njiru, Z. K., Mikosza, A. S. J., Armstrong, T. P., Enyaru, J., Ndung’u, J. M., & Thompson, A. (2008) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0000147 · Cited by 268 · see citing works
Imai, M., Ninomiya, A., Minekawa, H., Notomi, T., ISHIZAKI, T., Tashiro, M., & Odagiri, T. (2006) · Vaccine · doi:10.1016/j.vaccine.2006.05.046 · Cited by 184 · see citing works
Plasma IP-10, apoptotic and angiogenic factors associated with fatal cerebral malaria in India
Jain, V., Armah, H. B., Tongren, J. E., Ned, R. M., Wilson, N. O., Crawford, S. B., Joel, P. K., Singh, M. P., Nagpal, A. C., Dash, A., et al. (2008) · Malaria Journal · doi:10.1186/1475-2875-7-83 · Cited by 177 · see citing works
Self-citationLoop-Mediated Isothermal PCR (LAMP) for the Diagnosis of Falciparum Malaria
Paris, D. H., Imwong, M., Faiz, A. M., Hasan, M., Yunus, E. B., Silamut, K., Lee, S. J., Day, N. P. J., & Dondorp, A. M. (2007) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2007.77.972 · Cited by 132 · see citing works
Fukuda, S., Takao, S., Kuwayama, M., Shimazu, Y., & Miyazaki, K. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.44.4.1376-1381.2006 · Cited by 126 · see citing works
Varga, A., & James, D. (2006) · Journal of Virological Methods · doi:10.1016/j.jviromet.2006.08.014 · Cited by 114 · see citing works
Bronzan, R. N., McMorrow, M., & Kachur, S. P. (2008) · Molecular Diagnosis & Therapy · doi:10.1007/bf03256295 · Cited by 86 · see citing works
Self-citationLin, X., Chen, Y. M., Lu, Y., Yan, J.-Y., & Yan, J. (2008) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2008.10.012 · Cited by 67 · see citing works
Yamamura, M., Makimura, K., & Ota, Y. (2009) · Japanese Journal of Infectious Diseases · doi:10.7883/yoken.jjid.2009.20 · Cited by 59 · see citing works
Loop-mediated Isothermal Amplification (LAMP) test for detection of Trypanosoma evansi strain B
Njiru, Z. K., Ouma, J. O., Enyaru, J., & Dargantes, A. P. (2010) · Experimental Parasitology · doi:10.1016/j.exppara.2010.01.017 · Cited by 43 · see citing works
Zheng, C., Xie, P., & Chen, Y. (2002) · Parasitology International · doi:10.1016/s1383-5769(01)00094-0 · Cited by 17 · see citing works
[Rapid and simple detection of Legionella species by LAMP, a mew DNA amplification method].
Annaka, T. (2003) · PubMed · Cited by 16 · see citing works
Rapid and simple detection of Legionella species by LAMP, a new DNA amplification method
安中敏光 (2003) · Medical Entomology and Zoology · Cited by 15 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Becherer, L., Borst, N., Bakheit, M. A., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 432 · see citing works
Hofmann, N., Mwingira, F., Shekalaghe, S., Robinson, L. J., Mueller, I., & Felger, I. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001788 · Cited by 413 · see citing works
Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP)
Zhang, X., Lowe, S. B., & Gooding, J. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.039 · Cited by 370 · see citing works
Hopkins, H., González, I. J., Polley, S. D., Angutoko, P., Ategeka, J., Asiimwe, C., Agaba, B. B., Kyabayinze, D. J., Sutherland, C. J., Perkins, M. D., et al. (2013) · The Journal of Infectious Diseases · doi:10.1093/infdis/jit184 · Cited by 288 · see citing works
Malaria rapid diagnostic tests in elimination settings—can they find the last parasite?
McMorrow, M., Aidoo, M., & Kachur, S. P. (2011) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2011.03639.x · Cited by 205 · see citing works
Self-citationGene-Z: a device for point of care genetic testing using a smartphone
Stedtfeld, R. D., Tourlousse, D. M., Seyrig, G., Stedtfeld, T. M., Kronlein, M. R., Price, S., Ahmad, F. J., Gülari, E., Tiedje, J. M., & Hashsham, S. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21226a · Cited by 187 · see citing works
Digital LAMP in a sample self-digitization (SD) chip
Gansen, A., Herrick, A. M., Dimov, I. K., Lee, L. P., & Chiu, D. T. (2012) · Lab on a Chip · doi:10.1039/c2lc21247a · Cited by 187 · see citing works
Canine visceral leishmaniasis: Diagnosis and management of the reservoir living among us
Travi, B. L., Cordeiro‐da‐Silva, A., Dantas‐Torres, F., & Miró, G. (2018) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0006082 · Cited by 157 · see citing works
Obande, G. A., & Singh, K. K. B. (2020) · Infection and Drug Resistance · doi:10.2147/idr.s217571 · Cited by 154 · see citing works
Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests
Park, J.-W. (2022) · Biosensors · doi:10.3390/bios12100857 · Cited by 148 · see citing works
Britton, S., Cheng, Q., & McCarthy, J. S. (2016) · Malaria Journal · doi:10.1186/s12936-016-1158-0 · Cited by 132 · see citing works
Isothermal Amplification Using a Chemical Heating Device for Point-of-Care Detection of HIV-1
Curtis, K. A., Rudolph, D. L., Nejad, I., Singleton, J., Beddoe, A., Weigl, B. H., LaBarre, P., & Owen, S. M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031432 · Cited by 130 · see citing works
Evaluation of the Illumigene Malaria LAMP: A Robust Molecular Diagnostic Tool for Malaria Parasites
Lucchi, N. W., Gaye, M., Diallo, M. A., Goldman, I. F., Ljolje, D., Dème, A. B., Badiane, A. S., Ndiaye, Y. D., Barnwell, J. W., Udhayakumar, V., et al. (2016) · Scientific Reports · doi:10.1038/srep36808 · Cited by 125 · see citing works
Self-citationAdvances in biosensors and optical assays for diagnosis and detection of malaria
Ragavan, K. V., Kumar, S., Swaraj, S., & Neethirajan, S. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.037 · Cited by 127 · see citing works
Sturrock, H. J. W., Novotny, J., Kunene, S., Dlamini, S. N., Zulu, Z., Cohen, J. M., Hsiang, M. S., Greenhouse, B., & Gosling, R. D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063830 · Cited by 126 · see citing works
Abdul-Ghani, R. A., Al-Mekhlafi, A. M., & Karanis, P. (2012) · Acta Tropica · doi:10.1016/j.actatropica.2012.02.004 · Cited by 110 · see citing works
Poole, C. B., Li, Z., Alhassan, A., Guelig, D., Diesburg, S., Tanner, N. A., Zhang, Y., Evans, T. C., LaBarre, P., Wanji, S., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0169011 · Cited by 105 · see citing works
Niu, J. H., Jian, H., Guo, Q. X., Chen, C. L., Wang, X., Liu, Q., & Guo, Y. (2011) · Plant Pathology · doi:10.1111/j.1365-3059.2011.02562.x · Cited by 93 · see citing works
Point-of-care nucleic acid detection using nanotechnology
Hartman, M. R., Ruiz, R. C. H., Hamada, S., Xu, C., Yancey, K. G., Yu, Y., Han, W., & Luo, D. (2013) · Nanoscale · doi:10.1039/c3nr04015a · Cited by 89 · see citing works
Aydin-Schmidt, B., Xu, W., González, I. J., Polley, S. D., Bell, D., Shakely, D., Msellem, M. I., Björkman, A., & Mårtensson, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103905 · Cited by 87 · see citing works
Lucchi, N. W., Ljolje, D., Silva-Flannery, L. M., & Udhayakumar, V. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151437 · Cited by 87 · see citing works
Self-citationOriero, E. C., Jacobs, J. A., Geertruyden, J. V., Nwakanma, D. C., & D’Alessandro, U. (2014) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku343 · Cited by 84 · see citing works
Zhou, Q., Wang, L., Chen, J., Wang, R., Shi, Y., Li, C., Zhang, D., Yan, X., & Zhang, Y. (2014) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2014.06.008 · Cited by 85 · see citing works
Britton, S., Cheng, Q., Grigg, M. J., Poole, C. B., Pasay, C. J., William, T., Fornace, K., Anstey, N. M., Sutherland, C. J., DRAKELEY, C. J., et al. (2016) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0004443 · Cited by 82 · see citing works
Recent Progress in the Development of Diagnostic Tests for Malaria
Krampa, F. D., Aniweh, Y., Awandare, G. A., & Kanyong, P. (2017) · Diagnostics · doi:10.3390/diagnostics7030054 · Cited by 82 · see citing works
Diagnosing malaria in pregnancy: An update
Fried, M., Muehlenbachs, A., & Duffy, P. E. (2012) · Expert Review of Anti-infective Therapy · doi:10.1586/eri.12.98 · Cited by 80 · see citing works
Loop-Mediated Amplification Accelerated by Stem Primers
Gandelman, O. A., Jackson, R., Kiddle, G. A., & Tisi, L. C. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12129108 · Cited by 80 · see citing works
Zhang, X., Zhang, H., Pu, J., Qi, Y., Yu, Q., Xie, Y., & Peng, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082841 · Cited by 79 · see citing works
Patel, J. C., Oberstaller, J., Xayavong, M. V., Jothikumar, N., DeBarry, J. D., Srinivasamoorthy, G., Villegas, L., Escalante, A. A., da Silva, A. J., Peterson, D. S., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0054986 · Cited by 75 · see citing works
Self-citationAglietti, C., Luchi, N., Pepori, A. L., Bartolini, P., Pecori, F., Raio, A., Capretti, P., & Santini, A. (2019) · AMB Express · doi:10.1186/s13568-019-0774-9 · Cited by 75 · see citing works
Patel, J. C., Lucchi, N. W., Srivastava, P., Lin, J. T., Sugaram, R., Aruncharus, S., Bharti, P. K., Shukla, M. M., Congpuong, K., Satimai, W., et al. (2014) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu252 · Cited by 75 · see citing works
Self-citationLoop-mediated isothermal amplification test for the molecular diagnosis of malaria
Eun-Taek, H. (2013) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.12.144 · Cited by 70 · see citing works
A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or whole blood
Curtis, K. A., Morrison, D., Rudolph, D. L., Shankar, A., Bloomfield, L. S. P., Switzer, W. M., & Owen, S. M. (2018) · Journal of Virological Methods · doi:10.1016/j.jviromet.2018.02.012 · Cited by 70 · see citing works
Seo, J. H., Park, B. H., Oh, S. J., Choi, G., Kim, D. H., Lee, E. Y., & Seo, T. S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.051 · Cited by 64 · see citing works
Point‐of‐Care Diagnostic Platforms for Loop‐Mediated Isothermal Amplification
Atçeken, N., Alseed, M. M., Dabbagh, S. R., Yetisen, A. K., & Taşoğlu, S. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202201174 · Cited by 63 · see citing works
Vallejo, A. F., Martínez, N. L., González, I. J., Arévalo‐Herrera, M., & Herrera, S. (2015) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0003453 · Cited by 61 · see citing works
Diagnostic Methods for Non-Falciparum Malaria
Gimenez, A. M., Marques, R. F., Regiart, M. D., & Bargieri, D. Y. (2021) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2021.681063 · Cited by 61 · see citing works
Zhong, Q., Tian, J., Wang, B., & Wang, L. (2015) · Food Control · doi:10.1016/j.foodcont.2015.11.043 · Cited by 61 · see citing works
Chen, C., Liu, P., Zhao, X., Du, W., Feng, X., & Liu, B. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.07.164 · Cited by 61 · see citing works
Picot, S., Cucherat, M., & Bienvenu, A. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.07.009 · Cited by 62 · see citing works
Campos, I. M., Uribe, M. L., Cuesta, C., Franco-Gallego, A., Carmona-Fonseca, J., & Maestre, A. (2011) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2011.10-0507 · Cited by 59 · see citing works
Rypien, C., Chow, B. L., Chan, W. W. M., Church, D. L., & Pillai, D. R. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00806-17 · Cited by 58 · see citing works
Mohon, A. N., Elahi, R., Khan, W. A., Haque, R., Sullivan, D. J., & Alam, M. S. (2014) · Acta Tropica · doi:10.1016/j.actatropica.2014.02.016 · Cited by 58 · see citing works
Diagnosis of Brugian Filariasis by Loop-Mediated Isothermal Amplification
Poole, C. B., Tanner, N. A., Zhang, Y., Evans, T. C., & Carlow, C. K. S. (2012) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0001948 · Cited by 57 · see citing works
A Low-Cost Microfluidic Chip for Rapid Genotyping of Malaria-Transmitting Mosquitoes
Liu, C.-C., Mauk, M., Hart, R., Bonizzoni, M., Yan, G., & Bau, H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0042222 · Cited by 57 · see citing works
Mens, P. F., de Bes, H. M., Sondo, P., Laochan, N., Keereecharoen, L., van Amerongen, A., Flint, J., Sak, J. R. S., Proux, S., Tinto, H., et al. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.01426-12 · Cited by 53 · see citing works
Imai, K., Tarumoto, N., Misawa, K., Runtuwene, L. R., Sakai, J., Hayashida, K., Eshita, Y., Maeda, R., Tuda, J. S. B., Murakami, T., et al. (2017) · BMC Infectious Diseases · doi:10.1186/s12879-017-2718-9 · Cited by 55 · see citing works
Selection of fluorescent DNA dyes for real-time LAMP with portable and simple optics
Seyrig, G., Stedtfeld, R. D., Tourlousse, D. M., Ahmad, F. J., Towery, K., Cupples, A. M., Tiedje, J. M., & Hashsham, S. A. (2015) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2015.11.004 · Cited by 53 · see citing works
Charpentier, É., Benichou, E., Pagès, A., Chauvin, P., Fillaux, J., Valentin, A., Guegan, H., Guémas, E., Salabert, A., Armengol, C., et al. (2019) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2019.05.010 · Cited by 54 · see citing works
Efficient Detection of Pathogenic Leptospires Using 16S Ribosomal RNA
Backstedt, B. T., Büyüktanır, Ö., Lindow, J. C., Wunder, E. A., dos Reis, M. G., Usmani‐Brown, S., Ledizet, M., Ko, A. I., & Pal, U. (2015) · PLoS ONE · doi:10.1371/journal.pone.0128913 · Cited by 51 · see citing works
Identification of pork in meat products using real-time loop-mediated isothermal amplification
Yang, L., Fu, S., Peng, X., Li, L., Song, T., & Li, L. (2014) · Biotechnology & Biotechnological Equipment · doi:10.1080/13102818.2014.963789 · Cited by 51 · see citing works
Xu, J., Guan, Z.-X., Zhao, B., Wang, Y., Cao, Y., Zhang, H.-Q., Zhu, X.-Q., He, Y.-K., & Xia, C.-M. (2015) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0003668 · Cited by 49 · see citing works
Ultrasensitive loop mediated isothermal amplification (US-LAMP) to detect malaria for elimination
Mohon, A. N., Getie, S., Jahan, N., Alam, M. S., & Pillai, D. R. (2019) · Malaria Journal · doi:10.1186/s12936-019-2979-4 · Cited by 50 · see citing works
Sattabongkot, J., Tsuboi, T., Han, E., Bantuchai, S., & Buates, S. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.03313-13 · Cited by 49 · see citing works
Ghayour-Najafabadi, Z., Oormazdi, H., Akhlaghi, L., Meamar, A. R., Nateghpour, M., Farivar, L., & Razmjou, E. (2014) · Acta Tropica · doi:10.1016/j.actatropica.2014.03.029 · Cited by 48 · see citing works
Li, Y., Kumar, N., Gopalakrishnan, A. M., Ginocchio, C. C., Manji, R., Bythrow, M., Lemieux, B., & Kong, H. (2013) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2013.05.005 · Cited by 48 · see citing works
Surabattula, R., Vejandla, M. P., Mallepaddi, P. C., Faulstich, K., & Polavarapu, R. (2013) · Experimental Parasitology · doi:10.1016/j.exppara.2013.03.031 · Cited by 47 · see citing works
Koninck, A.-S. D., Cnops, L., Hofmans, M., Jacobs, J. A., den Bossche, D. V., & Philippé, J. (2017) · Malaria Journal · doi:10.1186/s12936-017-2065-8 · Cited by 48 · see citing works
Ponce, C., Kaczorowski, F., Perpoint, T., Miailhes, P., Sigal, A., Javouhey, É., Gillet, Y., Jacquin, L., Douplat, M., Tazarourte, K., et al. (2017) · Parasite · doi:10.1051/parasite/2017054 · Cited by 46 · see citing works
Detection of Acute HIV-1 Infection by RT-LAMP
Rudolph, D. L., Sullivan, V., Owen, S. M., & Curtis, K. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126609 · Cited by 46 · see citing works
Njiru, Z. K., Yeboah‐Manu, D., Stinear, T. P., & Fyfe, J. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.06460-11 · Cited by 45 · see citing works
Morris, U., & Aydin-Schmidt, B. (2021) · Diagnostics · doi:10.3390/diagnostics11020336 · Cited by 45 · see citing works
Ding, X., Wu, W., Zhu, Q., Zhang, T., Jin, W., & Mu, Y. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02112 · Cited by 44 · see citing works
Selvarajah, D., Naing, C. M., Htet, N. H., & Mak, J. W. (2020) · Malaria Journal · doi:10.1186/s12936-020-03283-9 · Cited by 44 · see citing works
Zhou, Q., Lu, J., Su, X., Jin, J., Li, S., Zhou, Y., Wang, L., Shao, X., Wang, Y., Yan, M., et al. (2020) · Journal of Fish Diseases · doi:10.1111/jfd.13325 · Cited by 43 · see citing works
Point of Care Testing for Malaria Using LAMP, Loop Mediated Isothermal Amplification
Hsiang, M. S., Greenhouse, B., & Rosenthal, P. J. (2014) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu253 · Cited by 43 · see citing works
Ide, T., Kanzaki, N., Ohmura, W., & Okabe, K. (2016) · Journal of Economic Entomology · doi:10.1093/jee/tow030 · Cited by 40 · see citing works
Rapid Detection of Influenza Virus Subtypes Based on an Integrated Centrifugal Disc
Yao, Y., Chen, X., Zhang, X., Liu, Q., Zhu, J., Wang, Z., Liu, S., & Sui, G. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02595 · Cited by 40 · see citing works
Chen, J.-W., Lau, Y. Y., Krishnan, T., Chan, K., & Chang, C. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.01104 · Cited by 39 · see citing works
Isothermal Detection of Mycoplasma pneumoniae Directly from Respiratory Clinical Specimens
Petrone, B. L., Wolff, B. J., DeLaney, A. A., Diaz, M. H., & Winchell, J. M. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.01431-15 · Cited by 37 · see citing works
Zhang, C., Yao, Y., Zhu, J.-L., Zhang, S., Zhang, S., Wei, H., Hui, W., & Cui, Y. (2016) · Scientific Reports · doi:10.1038/srep26533 · Cited by 38 · see citing works
Kemleu, S., Guelig, D., Moukoko, C. E. E., Essangui, E., Diesburg, S., Mouliom, A., Melingui, B., Manga, J., Donkeu, C. J., Epote, A. R., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165506 · Cited by 39 · see citing works
Imai, K., Tarumoto, N., Runtuwene, L. R., Sakai, J., Hayashida, K., Eshita, Y., Maeda, R., Tuda, J. S. B., Ohno, H., Murakami, T., et al. (2018) · Malaria Journal · doi:10.1186/s12936-018-2362-x · Cited by 37 · see citing works
Potential Serological Biomarkers of Cerebral Malaria
Lucchi, N. W., Jain, V., Wilson, N. O., Singh, N., Udhayakumar, V., & Stiles, J. K. (2011) · Disease Markers · doi:10.1155/2011/345706 · Cited by 38 · see citing works
Self-citationCao, Y., Wang, L., Duan, L., Li, J., Juan, M., Xie, S.-N., Shi, L., & Li, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-13881-4 · Cited by 37 · see citing works
Diagnosis of clinical malaria in endemic settings
Varo, R., Balanza, N., Mayor, A. G., & Bassat, Q. (2020) · Expert Review of Anti-infective Therapy · doi:10.1080/14787210.2020.1807940 · Cited by 40 · see citing works
Britton, S., Cheng, Q., Sutherland, C. J., & McCarthy, J. S. (2015) · Malaria Journal · doi:10.1186/s12936-015-0848-3 · Cited by 36 · see citing works
Peng, J., Zhan, Y., FanYun, Z., Long, H., Pei, Y., & Guo, J. (2013) · FEMS Microbiology Letters · doi:10.1111/1574-6968.12305 · Cited by 36 · see citing works
Yi, M., Li, L., Neogi, S. B., Fan, Y., Tang, D., Yamasaki, S., Shi, L., & Ye, L. (2014) · Food Control · doi:10.1016/j.foodcont.2014.01.005 · Cited by 36 · see citing works
MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
Ocker, R., Prompunjai, Y., Chutipongvivate, S., & Karanis, P. (2016) · Revista do Instituto de Medicina Tropical de São Paulo · doi:10.1590/s1678-9946201658027 · Cited by 36 · see citing works
Wang, Q., Zhou, Y., Li, S., Zhuo, C., Xu, S., Huang, L., Yang, L., & Liao, K. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066406 · Cited by 36 · see citing works
Jhou, Y.-R., Wang, C., Tsai, H., Shan, Y.-S., & Lee, G. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131447 · Cited by 35 · see citing works
Kshirsagar, A., Choi, G., Santosh, V., Harvey, T., Bernhards, R. C., & Guan, W. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02169 · Cited by 33 · see citing works
Lucchi, N. W., Ndiaye, D., Britton, S., & Udhayakumar, V. (2018) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2018.1431529 · Cited by 32 · see citing works
Self-citationPeng, J., Zhang, H., Chen, F., Zhang, X., Xie, Y., Hou, X., Li, G., & Pu, J. (2014) · Journal of Applied Microbiology · doi:10.1111/jam.12645 · Cited by 33 · see citing works
Kudyba, H. M., Louzada, J., Ljolje, D., Kudyba, K. A., Muralidharan, V., Oliveira-Ferreira, J., & Lucchi, N. W. (2019) · Malaria Journal · doi:10.1186/s12936-019-2722-1 · Cited by 31 · see citing works
Self-citationLAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients
Cuadros‐González, J., Ramírez, A. M., González, I. J., Ding, X. C., Pérez‐Tanoira, R., Rojo-Marcos, G., Gómez-Herruz, P., & Rubio, J. M. (2017) · Malaria Journal · doi:10.1186/s12936-016-1669-8 · Cited by 29 · see citing works
Cheaveau, J., Nguyen, H., Chow, B. L., Marasinghe, D. H., Mohon, A. N., Yuan, H., Viana, G. M. R., van Schalkwyk, D. A., Church, D. L., Chan, W. W. M., et al. (2018) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofy260 · Cited by 30 · see citing works
Cai, Z., Dai, Y., Huang, L., Zhang, W., & Guo, X. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3799-4 · Cited by 31 · see citing works
Denschlag, C., Vogel, R. F., & Niessen, L. (2013) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2013.01.019 · Cited by 30 · see citing works
Tambo, M., Mwinga, M., & Mumbengegwi, D. R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0206848 · Cited by 29 · see citing works
Xiong, X., Huang, M., Xu, W., Li, Y., Cao, M., & Xiong, X. (2020) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2020.103659 · Cited by 29 · see citing works
Wang, X., Zhang, Q., Zhang, F., Ma, F., Zheng, W., Zhao, Z., Bai, Y., & Zheng, L. (2012) · Virology Journal · doi:10.1186/1743-422x-9-138 · Cited by 29 · see citing works
Canavese, M., & Spaccapelo, R. (2014) · Pathogens and Global Health · doi:10.1179/2047773214y.0000000130 · Cited by 28 · see citing works
Turfgrass Disease Diagnosis: Past, Present, and Future
Stackhouse, T., Martinez-Espinoza, A. D., & Ali, M. E. (2020) · Plants · doi:10.3390/plants9111544 · Cited by 28 · see citing works
A Sensitive and Specific Fluorescent RT-LAMP Assay for SARS-CoV-2 Detection in Clinical Samples
Ooi, K. H., Liu, M. M., Moo, J. R., Nimsamer, P., Payungporn, S., Kaewsapsak, P., & Tan, M. H. (2022) · ACS Synthetic Biology · doi:10.1021/acssynbio.1c00538 · Cited by 28 · see citing works
Rizzo, D., Taddei, A., Lio, D. D., Bruscoli, T., Cappellini, G., Bartolini, L., Salemi, C., Luchi, N., Pennacchio, F., & Rossi, E. (2020) · Journal of Economic Entomology · doi:10.1093/jee/toaa206 · Cited by 27 · see citing works
Mens, P. F., Moers, A. P. H. A., de Bes, L., Flint, J., Sak, J. R. S., Keereecharoen, L., Overmeir, C. V., Verweij, J. J., Hallett, R., Wihokhoen, B., et al. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-279 · Cited by 27 · see citing works
Rapid detection of Streptococcus uberis in raw milk by loop-mediated isothermal amplification
Cornelissen, J. B. W. J., de Greeff, A., Heuvelink, A., Swarts, M. J., Smith, H. E., & van der Wal, F. J. (2016) · Journal of Dairy Science · doi:10.3168/jds.2015-10683 · Cited by 26 · see citing works
Lee, P.-W., Ji, D.-D., Liu, C.-T., Rampão, H. S., do Rosário, V. E., Lin, I., & Shaio, M. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-408 · Cited by 25 · see citing works
- Authors
- Lucchi, N. W., Demas, A., Narayanan, J., Sumari, D., Kabanywanyi, A., Kachur, S. P., Barnwell, J. W., & Udhayakumar, V.
- Affiliations
- Centers for Disease Control and Prevention (US)
- Ifakara Health Institute (TZ)
- Corresponding author
- Lucchi, Naomi W.
- ORCID
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-10-29
- Volume
- 5
- Issue
- 10
- Pages
- e13733
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2966401
- OpenAlex
- W1991198490
- Cited by
- 198
- References
- 23
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 10 · 2023: 7 · 2022: 11 · 2021: 6 · 2020: 15 · 2019: 12 · 2018: 18 · 2017: 12 · 2016: 16 · 2015: 18 · 2014: 29 · 2013: 14 · 2012: 16
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Association of Public Health Laboratories
- Centers for Disease Control and Prevention
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Keywords
- malaria diagnosis, loop-mediated isothermal amplification, real-time fluorescence detection, portable diagnostic device, Plasmodium falciparum, Plasmodium species detection, sensitivity and specificity
- MeSH terms
- Animals, Fluorescence, Humans, Malaria, Plasmodium, Sensitivity and Specificity, DNA, Protozoan, Polymerase Chain Reaction, Molecular Diagnostic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review