The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Real-Time Fluorescence Loop Mediated Isothermal Amplification for the Diagnosis of Malaria
Open accessAbstract
BACKGROUND: Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. METHODOLOGY AND SIGNIFICANT FINDINGS: Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. CONCLUSION: This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Several studies that compared the LAMP method to microscopy, PCR and RDT, reported high sensitivity and specificity compared with microscopy or PCR in nonpregnant populations [34–37].”
From Diagnosing malaria in pregnancy: An update (2012) · cites this paper as [36]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Weltgesundheitsorganisation (2005) · Cited by 3,799
Accelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,075
Plasmodium knowlesi Malaria in Humans Is Widely Distributed and Potentially Life Threatening
Cox‐Singh, J., Davis, T. M. E., Lee, K.-S., Shamsul, S. S., Matusop, A., Ratnam, S., Rahman, H., Conway, D. J., & Singh, B. B. (2007) · Clinical Infectious Diseases · doi:10.1086/524888 · Cited by 884
Singh, B. B., Bobogare, A., Cox‐Singh, J., Snounou, G., Abdullah, M. S., & Rahman, H. (1999) · American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.1999.60.687 · Cited by 593
Gamboa, D., Ho, M., Bendezú, J., Torres, K., Chiodini, P. L., Barnwell, J. W., Incardona, S., Perkins, M. D., Bell, D., McCarthy, J. S., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008091 · Cited by 547
Self-citationPoon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476
Parida, M., Posadas-Herrera, G., Inoue, S., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.1.257-263.2004 · Cited by 439
Thai, H. T. C., Le, M. Q., Vuong, C. D., Parida, M., Minekawa, H., Notomi, T., Hasebe, F., & Morita, K. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.1956-1961.2004 · Cited by 423
Han, E., Watanabe, R., Sattabongkot, J., Khuntirat, B., Sirichaisinthop, J., Iriko, H., Jin, L., Takeo, S., & Tsuboi, T. (2007) · Journal of Clinical Microbiology · doi:10.1128/jcm.02117-06 · Cited by 277
Cited by
Sorted by citations
Becherer, L., Borst, N., Bakheit, M. A., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 432
Hofmann, N., Mwingira, F., Shekalaghe, S., Robinson, L. J., Mueller, I., & Felger, I. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001788 · Cited by 413
Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP)
Zhang, X., Lowe, S. B., & Gooding, J. J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.039 · Cited by 370
Hopkins, H., González, I. J., Polley, S. D., Angutoko, P., Ategeka, J., Asiimwe, C., Agaba, B. B., Kyabayinze, D. J., Sutherland, C. J., Perkins, M. D., et al. (2013) · The Journal of Infectious Diseases · doi:10.1093/infdis/jit184 · Cited by 288
Malaria rapid diagnostic tests in elimination settings—can they find the last parasite?
McMorrow, M., Aidoo, M., & Kachur, S. P. (2011) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2011.03639.x · Cited by 205
Self-citationGene-Z: a device for point of care genetic testing using a smartphone
Stedtfeld, R. D., Tourlousse, D. M., Seyrig, G., Stedtfeld, T. M., Kronlein, M. R., Price, S., Ahmad, F. J., Gülari, E., Tiedje, J. M., & Hashsham, S. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21226a · Cited by 187
Digital LAMP in a sample self-digitization (SD) chip
Gansen, A., Herrick, A. M., Dimov, I. K., Lee, L. P., & Chiu, D. T. (2012) · Lab on a Chip · doi:10.1039/c2lc21247a · Cited by 187
Canine visceral leishmaniasis: Diagnosis and management of the reservoir living among us
Travi, B. L., Cordeiro‐da‐Silva, A., Dantas‐Torres, F., & Miró, G. (2018) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0006082 · Cited by 157
Obande, G. A., & Singh, K. K. B. (2020) · Infection and Drug Resistance · doi:10.2147/idr.s217571 · Cited by 154
Principles and Applications of Loop-Mediated Isothermal Amplification to Point-of-Care Tests
Park, J.-W. (2022) · Biosensors · doi:10.3390/bios12100857 · Cited by 169
Britton, S., Cheng, Q., & McCarthy, J. S. (2016) · Malaria Journal · doi:10.1186/s12936-016-1158-0 · Cited by 132
Isothermal Amplification Using a Chemical Heating Device for Point-of-Care Detection of HIV-1
Curtis, K. A., Rudolph, D. L., Nejad, I., Singleton, J., Beddoe, A., Weigl, B. H., LaBarre, P., & Owen, S. M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031432 · Cited by 130
Evaluation of the Illumigene Malaria LAMP: A Robust Molecular Diagnostic Tool for Malaria Parasites
Lucchi, N. W., Gaye, M., Diallo, M. A., Goldman, I. F., Ljolje, D., Dème, A. B., Badiane, A. S., Ndiaye, Y. D., Barnwell, J. W., Udhayakumar, V., et al. (2016) · Scientific Reports · doi:10.1038/srep36808 · Cited by 125
Self-citationAdvances in biosensors and optical assays for diagnosis and detection of malaria
Ragavan, K. V., Kumar, S., Swaraj, S., & Neethirajan, S. R. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.037 · Cited by 127
Sturrock, H. J. W., Novotny, J., Kunene, S., Dlamini, S. N., Zulu, Z., Cohen, J. M., Hsiang, M. S., Greenhouse, B., & Gosling, R. D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063830 · Cited by 126
Abdul-Ghani, R. A., Al-Mekhlafi, A. M., & Karanis, P. (2012) · Acta Tropica · doi:10.1016/j.actatropica.2012.02.004 · Cited by 110
Poole, C. B., Li, Z., Alhassan, A., Guelig, D., Diesburg, S., Tanner, N. A., Zhang, Y., Evans, T. C., LaBarre, P., Wanji, S., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0169011 · Cited by 105
Niu, J. H., Jian, H., Guo, Q. X., Chen, C. L., Wang, X., Liu, Q., & Guo, Y. (2011) · Plant Pathology · doi:10.1111/j.1365-3059.2011.02562.x · Cited by 93
Point-of-care nucleic acid detection using nanotechnology
Hartman, M. R., Ruiz, R. C. H., Hamada, S., Xu, C., Yancey, K. G., Yu, Y., Han, W., & Luo, D. (2013) · Nanoscale · doi:10.1039/c3nr04015a · Cited by 89
Aydin-Schmidt, B., Xu, W., González, I. J., Polley, S. D., Bell, D., Shakely, D., Msellem, M. I., Björkman, A., & Mårtensson, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103905 · Cited by 87
Lucchi, N. W., Ljolje, D., Silva-Flannery, L. M., & Udhayakumar, V. (2016) · PLoS ONE · doi:10.1371/journal.pone.0151437 · Cited by 87
Self-citationOriero, E. C., Jacobs, J. A., Geertruyden, J. V., Nwakanma, D. C., & D’Alessandro, U. (2014) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku343 · Cited by 84
Zhou, Q., Wang, L., Chen, J., Wang, R., Shi, Y., Li, C., Zhang, D., Yan, X., & Zhang, Y. (2014) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2014.06.008 · Cited by 85
Britton, S., Cheng, Q., Grigg, M. J., Poole, C. B., Pasay, C. J., William, T., Fornace, K., Anstey, N. M., Sutherland, C. J., DRAKELEY, C. J., et al. (2016) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0004443 · Cited by 82
Recent Progress in the Development of Diagnostic Tests for Malaria
Krampa, F. D., Aniweh, Y., Awandare, G. A., & Kanyong, P. (2017) · Diagnostics · doi:10.3390/diagnostics7030054 · Cited by 82
Diagnosing malaria in pregnancy: An update
Fried, M., Muehlenbachs, A., & Duffy, P. E. (2012) · Expert Review of Anti-infective Therapy · doi:10.1586/eri.12.98 · Cited by 80
Loop-Mediated Amplification Accelerated by Stem Primers
Gandelman, O. A., Jackson, R., Kiddle, G. A., & Tisi, L. C. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12129108 · Cited by 80
Zhang, X., Zhang, H., Pu, J., Qi, Y., Yu, Q., Xie, Y., & Peng, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082841 · Cited by 79
Patel, J. C., Oberstaller, J., Xayavong, M. V., Jothikumar, N., DeBarry, J. D., Srinivasamoorthy, G., Villegas, L., Escalante, A. A., da Silva, A. J., Peterson, D. S., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0054986 · Cited by 75
Self-citationAglietti, C., Luchi, N., Pepori, A. L., Bartolini, P., Pecori, F., Raio, A., Capretti, P., & Santini, A. (2019) · AMB Express · doi:10.1186/s13568-019-0774-9 · Cited by 75
Patel, J. C., Lucchi, N. W., Srivastava, P., Lin, J. T., Sugaram, R., Aruncharus, S., Bharti, P. K., Shukla, M. M., Congpuong, K., Satimai, W., et al. (2014) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu252 · Cited by 75
Self-citationLoop-mediated isothermal amplification test for the molecular diagnosis of malaria
Eun-Taek, H. (2013) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.12.144 · Cited by 68
A multiplexed RT-LAMP assay for detection of group M HIV-1 in plasma or whole blood
Curtis, K. A., Morrison, D., Rudolph, D. L., Shankar, A., Bloomfield, L. S. P., Switzer, W. M., & Owen, S. M. (2018) · Journal of Virological Methods · doi:10.1016/j.jviromet.2018.02.012 · Cited by 70
Seo, J. H., Park, B. H., Oh, S. J., Choi, G., Kim, D. H., Lee, E. Y., & Seo, T. S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.051 · Cited by 64
Point‐of‐Care Diagnostic Platforms for Loop‐Mediated Isothermal Amplification
Atçeken, N., Alseed, M. M., Dabbagh, S. R., Yetisen, A. K., & Taşoğlu, S. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202201174 · Cited by 63
Vallejo, A. F., Martínez, N. L., González, I. J., Arévalo‐Herrera, M., & Herrera, S. (2015) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0003453 · Cited by 61
Diagnostic Methods for Non-Falciparum Malaria
Gimenez, A. M., Marques, R. F., Regiart, M. D., & Bargieri, D. Y. (2021) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2021.681063 · Cited by 62
Zhong, Q., Tian, J., Wang, B., & Wang, L. (2015) · Food Control · doi:10.1016/j.foodcont.2015.11.043 · Cited by 61
Chen, C., Liu, P., Zhao, X., Du, W., Feng, X., & Liu, B. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.07.164 · Cited by 61
Picot, S., Cucherat, M., & Bienvenu, A. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.07.009 · Cited by 64
Campos, I. M., Uribe, M. L., Cuesta, C., Franco-Gallego, A., Carmona-Fonseca, J., & Maestre, A. (2011) · The American Society of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2011.10-0507 · Cited by 59
Rypien, C., Chow, B. L., Chan, W. W. M., Church, D. L., & Pillai, D. R. (2017) · Journal of Clinical Microbiology · doi:10.1128/jcm.00806-17 · Cited by 58
Mohon, A. N., Elahi, R., Khan, W. A., Haque, R., Sullivan, D. J., & Alam, M. S. (2014) · Acta Tropica · doi:10.1016/j.actatropica.2014.02.016 · Cited by 58
Diagnosis of Brugian Filariasis by Loop-Mediated Isothermal Amplification
Poole, C. B., Tanner, N. A., Zhang, Y., Evans, T. C., & Carlow, C. K. S. (2012) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0001948 · Cited by 57
A Low-Cost Microfluidic Chip for Rapid Genotyping of Malaria-Transmitting Mosquitoes
Liu, C.-C., Mauk, M., Hart, R., Bonizzoni, M., Yan, G., & Bau, H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0042222 · Cited by 57
Mens, P. F., de Bes, H. M., Sondo, P., Laochan, N., Keereecharoen, L., van Amerongen, A., Flint, J., Sak, J. R. S., Proux, S., Tinto, H., et al. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.01426-12 · Cited by 53
Imai, K., Tarumoto, N., Misawa, K., Runtuwene, L. R., Sakai, J., Hayashida, K., Eshita, Y., Maeda, R., Tuda, J. S. B., Murakami, T., et al. (2017) · BMC Infectious Diseases · doi:10.1186/s12879-017-2718-9 · Cited by 55
Selection of fluorescent DNA dyes for real-time LAMP with portable and simple optics
Seyrig, G., Stedtfeld, R. D., Tourlousse, D. M., Ahmad, F. J., Towery, K., Cupples, A. M., Tiedje, J. M., & Hashsham, S. A. (2015) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2015.11.004 · Cited by 54
Charpentier, É., Benichou, E., Pagès, A., Chauvin, P., Fillaux, J., Valentin, A., Guegan, H., Guémas, E., Salabert, A., Armengol, C., et al. (2019) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2019.05.010 · Cited by 54
Efficient Detection of Pathogenic Leptospires Using 16S Ribosomal RNA
Backstedt, B. T., Büyüktanır, Ö., Lindow, J. C., Wunder, E. A., dos Reis, M. G., Usmani‐Brown, S., Ledizet, M., Ko, A. I., & Pal, U. (2015) · PLoS ONE · doi:10.1371/journal.pone.0128913 · Cited by 51
Identification of pork in meat products using real-time loop-mediated isothermal amplification
Yang, L., Fu, S., Peng, X., Li, L., Song, T., & Li, L. (2014) · Biotechnology & Biotechnological Equipment · doi:10.1080/13102818.2014.963789 · Cited by 51
Xu, J., Guan, Z.-X., Zhao, B., Wang, Y., Cao, Y., Zhang, H.-Q., Zhu, X.-Q., He, Y.-K., & Xia, C.-M. (2015) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0003668 · Cited by 49
Ultrasensitive loop mediated isothermal amplification (US-LAMP) to detect malaria for elimination
Mohon, A. N., Getie, S., Jahan, N., Alam, M. S., & Pillai, D. R. (2019) · Malaria Journal · doi:10.1186/s12936-019-2979-4 · Cited by 50
Sattabongkot, J., Tsuboi, T., Han, E., Bantuchai, S., & Buates, S. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.03313-13 · Cited by 49
Ghayour-Najafabadi, Z., Oormazdi, H., Akhlaghi, L., Meamar, A. R., Nateghpour, M., Farivar, L., & Razmjou, E. (2014) · Acta Tropica · doi:10.1016/j.actatropica.2014.03.029 · Cited by 48
Li, Y., Kumar, N., Gopalakrishnan, A. M., Ginocchio, C. C., Manji, R., Bythrow, M., Lemieux, B., & Kong, H. (2013) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2013.05.005 · Cited by 48
Surabattula, R., Vejandla, M. P., Mallepaddi, P. C., Faulstich, K., & Polavarapu, R. (2013) · Experimental Parasitology · doi:10.1016/j.exppara.2013.03.031 · Cited by 47
Koninck, A.-S. D., Cnops, L., Hofmans, M., Jacobs, J. A., den Bossche, D. V., & Philippé, J. (2017) · Malaria Journal · doi:10.1186/s12936-017-2065-8 · Cited by 48
Ponce, C., Kaczorowski, F., Perpoint, T., Miailhes, P., Sigal, A., Javouhey, É., Gillet, Y., Jacquin, L., Douplat, M., Tazarourte, K., et al. (2017) · Parasite · doi:10.1051/parasite/2017054 · Cited by 46
Detection of Acute HIV-1 Infection by RT-LAMP
Rudolph, D. L., Sullivan, V., Owen, S. M., & Curtis, K. A. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126609 · Cited by 46
Njiru, Z. K., Yeboah‐Manu, D., Stinear, T. P., & Fyfe, J. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.06460-11 · Cited by 45
Morris, U., & Aydin-Schmidt, B. (2021) · Diagnostics · doi:10.3390/diagnostics11020336 · Cited by 45
Ding, X., Wu, W., Zhu, Q., Zhang, T., Jin, W., & Mu, Y. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02112 · Cited by 44
Selvarajah, D., Naing, C. M., Htet, N. H., & Mak, J. W. (2020) · Malaria Journal · doi:10.1186/s12936-020-03283-9 · Cited by 44
Zhou, Q., Lu, J., Su, X., Jin, J., Li, S., Zhou, Y., Wang, L., Shao, X., Wang, Y., Yan, M., et al. (2020) · Journal of Fish Diseases · doi:10.1111/jfd.13325 · Cited by 43
Point of Care Testing for Malaria Using LAMP, Loop Mediated Isothermal Amplification
Hsiang, M. S., Greenhouse, B., & Rosenthal, P. J. (2014) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu253 · Cited by 43
Ide, T., Kanzaki, N., Ohmura, W., & Okabe, K. (2016) · Journal of Economic Entomology · doi:10.1093/jee/tow030 · Cited by 40
Rapid Detection of Influenza Virus Subtypes Based on an Integrated Centrifugal Disc
Yao, Y., Chen, X., Zhang, X., Liu, Q., Zhu, J., Wang, Z., Liu, S., & Sui, G. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02595 · Cited by 40
Chen, J.-W., Lau, Y. Y., Krishnan, T., Chan, K., & Chang, C. (2018) · Frontiers in Microbiology · doi:10.3389/fmicb.2018.01104 · Cited by 39
Isothermal Detection of Mycoplasma pneumoniae Directly from Respiratory Clinical Specimens
Petrone, B. L., Wolff, B. J., DeLaney, A. A., Diaz, M. H., & Winchell, J. M. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.01431-15 · Cited by 37
Zhang, C., Yao, Y., Zhu, J.-L., Zhang, S., Zhang, S., Wei, H., Hui, W., & Cui, Y. (2016) · Scientific Reports · doi:10.1038/srep26533 · Cited by 38
Kemleu, S., Guelig, D., Moukoko, C. E. E., Essangui, E., Diesburg, S., Mouliom, A., Melingui, B., Manga, J., Donkeu, C. J., Epote, A. R., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165506 · Cited by 39
Imai, K., Tarumoto, N., Runtuwene, L. R., Sakai, J., Hayashida, K., Eshita, Y., Maeda, R., Tuda, J. S. B., Ohno, H., Murakami, T., et al. (2018) · Malaria Journal · doi:10.1186/s12936-018-2362-x · Cited by 37
Potential Serological Biomarkers of Cerebral Malaria
Lucchi, N. W., Jain, V., Wilson, N. O., Singh, N., Udhayakumar, V., & Stiles, J. K. (2011) · Disease Markers · doi:10.1155/2011/345706 · Cited by 38
Self-citationCao, Y., Wang, L., Duan, L., Li, J., Juan, M., Xie, S.-N., Shi, L., & Li, H. (2017) · Scientific Reports · doi:10.1038/s41598-017-13881-4 · Cited by 38
Diagnosis of clinical malaria in endemic settings
Varo, R., Balanza, N., Mayor, A. G., & Bassat, Q. (2020) · Expert Review of Anti-infective Therapy · doi:10.1080/14787210.2020.1807940 · Cited by 40
Britton, S., Cheng, Q., Sutherland, C. J., & McCarthy, J. S. (2015) · Malaria Journal · doi:10.1186/s12936-015-0848-3 · Cited by 36
Peng, J., Zhan, Y., FanYun, Z., Long, H., Pei, Y., & Guo, J. (2013) · FEMS Microbiology Letters · doi:10.1111/1574-6968.12305 · Cited by 36
Yi, M., Li, L., Neogi, S. B., Fan, Y., Tang, D., Yamasaki, S., Shi, L., & Ye, L. (2014) · Food Control · doi:10.1016/j.foodcont.2014.01.005 · Cited by 36
MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
Ocker, R., Prompunjai, Y., Chutipongvivate, S., & Karanis, P. (2016) · Revista do Instituto de Medicina Tropical de São Paulo · doi:10.1590/s1678-9946201658027 · Cited by 36
Wang, Q., Zhou, Y., Li, S., Zhuo, C., Xu, S., Huang, L., Yang, L., & Liao, K. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066406 · Cited by 36
Jhou, Y.-R., Wang, C., Tsai, H., Shan, Y.-S., & Lee, G. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131447 · Cited by 35
Kshirsagar, A., Choi, G., Santosh, V., Harvey, T., Bernhards, R. C., & Guan, W. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02169 · Cited by 33
Lucchi, N. W., Ndiaye, D., Britton, S., & Udhayakumar, V. (2018) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2018.1431529 · Cited by 32
Self-citationPeng, J., Zhang, H., Chen, F., Zhang, X., Xie, Y., Hou, X., Li, G., & Pu, J. (2014) · Journal of Applied Microbiology · doi:10.1111/jam.12645 · Cited by 33
Kudyba, H. M., Louzada, J., Ljolje, D., Kudyba, K. A., Muralidharan, V., Oliveira-Ferreira, J., & Lucchi, N. W. (2019) · Malaria Journal · doi:10.1186/s12936-019-2722-1 · Cited by 31
Self-citationLAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients
Cuadros‐González, J., Ramírez, A. M., González, I. J., Ding, X. C., Pérez‐Tanoira, R., Rojo-Marcos, G., Gómez-Herruz, P., & Rubio, J. M. (2017) · Malaria Journal · doi:10.1186/s12936-016-1669-8 · Cited by 29
Cheaveau, J., Nguyen, H., Chow, B. L., Marasinghe, D. H., Mohon, A. N., Yuan, H., Viana, G. M. R., van Schalkwyk, D. A., Church, D. L., Chan, W. W. M., et al. (2018) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofy260 · Cited by 30
Cai, Z., Dai, Y., Huang, L., Zhang, W., & Guo, X. (2019) · BMC Infectious Diseases · doi:10.1186/s12879-019-3799-4 · Cited by 31
Denschlag, C., Vogel, R. F., & Niessen, L. (2013) · International Journal of Food Microbiology · doi:10.1016/j.ijfoodmicro.2013.01.019 · Cited by 31
Tambo, M., Mwinga, M., & Mumbengegwi, D. R. (2018) · PLoS ONE · doi:10.1371/journal.pone.0206848 · Cited by 30
Xiong, X., Huang, M., Xu, W., Li, Y., Cao, M., & Xiong, X. (2020) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2020.103659 · Cited by 29
Wang, X., Zhang, Q., Zhang, F., Ma, F., Zheng, W., Zhao, Z., Bai, Y., & Zheng, L. (2012) · Virology Journal · doi:10.1186/1743-422x-9-138 · Cited by 29
Canavese, M., & Spaccapelo, R. (2014) · Pathogens and Global Health · doi:10.1179/2047773214y.0000000130 · Cited by 28
Turfgrass Disease Diagnosis: Past, Present, and Future
Stackhouse, T., Martinez-Espinoza, A. D., & Ali, M. E. (2020) · Plants · doi:10.3390/plants9111544 · Cited by 28
A Sensitive and Specific Fluorescent RT-LAMP Assay for SARS-CoV-2 Detection in Clinical Samples
Ooi, K. H., Liu, M. M., Moo, J. R., Nimsamer, P., Payungporn, S., Kaewsapsak, P., & Tan, M. H. (2022) · ACS Synthetic Biology · doi:10.1021/acssynbio.1c00538 · Cited by 28
Rizzo, D., Taddei, A., Lio, D. D., Bruscoli, T., Cappellini, G., Bartolini, L., Salemi, C., Luchi, N., Pennacchio, F., & Rossi, E. (2020) · Journal of Economic Entomology · doi:10.1093/jee/toaa206 · Cited by 27
Mens, P. F., Moers, A. P. H. A., de Bes, L., Flint, J., Sak, J. R. S., Keereecharoen, L., Overmeir, C. V., Verweij, J. J., Hallett, R., Wihokhoen, B., et al. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-279 · Cited by 27
Rapid detection of Streptococcus uberis in raw milk by loop-mediated isothermal amplification
Cornelissen, J. B. W. J., de Greeff, A., Heuvelink, A., Swarts, M. J., Smith, H. E., & van der Wal, F. J. (2016) · Journal of Dairy Science · doi:10.3168/jds.2015-10683 · Cited by 26
Lee, P.-W., Ji, D.-D., Liu, C.-T., Rampão, H. S., do Rosário, V. E., Lin, I., & Shaio, M. (2012) · Malaria Journal · doi:10.1186/1475-2875-11-408 · Cited by 25
Metadata
- Authors
- Lucchi, N. W., Demas, A., Narayanan, J., Sumari, D., Kabanywanyi, A., Kachur, S. P., Barnwell, J. W., & Udhayakumar, V.
- Affiliations
- Centers for Disease Control and Prevention (US)
- Ifakara Health Institute (TZ)
- Corresponding author
- Lucchi, Naomi W.
- ORCID
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-10-29
- Volume
- 5
- Issue
- 10
- Pages
- e13733
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2966401
- OpenAlex
- W1991198490
- Cited by
- 198
- References
- 23
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 10 · 2023: 7 · 2022: 11 · 2021: 6 · 2020: 15 · 2019: 12 · 2018: 18 · 2017: 12 · 2016: 16 · 2015: 18 · 2014: 29 · 2013: 14 · 2012: 16
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Association of Public Health Laboratories
- Centers for Disease Control and Prevention
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Keywords
- malaria diagnosis, loop-mediated isothermal amplification, real-time fluorescence detection, portable diagnostic device, Plasmodium falciparum, Plasmodium species detection, sensitivity and specificity
- MeSH terms
- Animals, Fluorescence, Humans, Malaria, Plasmodium, Sensitivity and Specificity, DNA, Protozoan, Polymerase Chain Reaction, Molecular Diagnostic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review