Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Influenza is thought to be communicated from person to person by multiple pathways. However, the relative importance of different routes of influenza transmission is unclear. To better understand the potential for the airborne spread of influenza, we measured the amount and size of aerosol particles containing influenza virus that were produced by coughing. Subjects were recruited from patients presenting at a student health clinic with influenza-like symptoms. Nasopharyngeal swabs were collected from the volunteers and they were asked to cough three times into a spirometer. After each cough, the cough-generated aerosol was collected using a NIOSH two-stage bioaerosol cyclone sampler or an SKC BioSampler. The amount of influenza viral RNA contained in the samplers was analyzed using quantitative real-time reverse-transcription PCR (qPCR) targeting the matrix gene M1. For half of the subjects, viral plaque assays were performed on the nasopharyngeal swabs and cough aerosol samples to determine if viable virus was present. Fifty-eight subjects were tested, of whom 47 were positive for influenza virus by qPCR. Influenza viral RNA was detected in coughs from 38 of these subjects (81%). Thirty-five percent of the influenza RNA was contained in particles>4 µm in aerodynamic diameter, while 23% was in particles 1 to 4 µm and 42% in particles<1 µm. Viable influenza virus was detected in the cough aerosols from 2 of 21 subjects with influenza. These results show that coughing by influenza patients emits aerosol particles containing influenza virus and that much of the viral RNA is contained within particles in the respirable size range. The results support the idea that the airborne route may be a pathway for influenza transmission, especially in the immediate vicinity of an influenza patient. Further research is needed on the viability of airborne influenza viruses and the risk of transmission.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Numerous earlier studies have established that aerosol expelled during normal respiratory activities can contain infectious influenza virus [42, 45–54].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [48]
The cited source says what the claim attributes to it.
In the citing paper
“Field data instead show higher SARS- CoV-2 and influenza RNA counts in finer fractions [47,58]”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [58]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harrison's Principles of Internal Medicine.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-499_2 · Cited by 12,514
Superspreading and the effect of individual variation on disease emergence
Lloyd-Smith, J. O., Schreiber, S. J., Kopp, P. E., & Getz, W. M. (2005) · Nature · doi:10.1038/nature04153 · Cited by 2,514
Time Lines of Infection and Disease in Human Influenza: A Review of Volunteer Challenge Studies
Carrat, F., Vergu, E., Ferguson, N. M., Lemaitre, M., Cauchemez, S., Leach, S., & Valleron, A.-J. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm375 · Cited by 1,133 · cited 2×
“Large variations in the amount of virus in cough aerosols are not surprising, since influenza viral shedding varies significantly from patient to patient and over the course of the illness [12], and since previous studies have shown that some individuals shed much greater quantities of aerosol particles during breathi…”
BackgroundResultChao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087 · cited 1×
“First, studies of cough-generated aerosols have shown that human coughs produce a tremendous range of particle sizes, ranging from less than 100 nm to visible drops larger than a millimeter [18,19,20,21].”
BackgroundDocumentation of the Threshold Limit Values and Biological Exposure Indices
Acgih (2001) · Medical Entomology and Zoology · Cited by 845
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803 · cited 2×
“Particles in this size fraction are of particular concern because some human experiments have suggested that a much smaller dose of influenza virus is needed to initiate an infection when it is deposited in the alveolar region compared to intranasal inoculation [8].”
BackgroundTransmission of influenza A in human beings
Brankston, G., Gitterman, L., Hirji, Z., Lemieux, C., & Gardam, M. (2007) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(07)70029-4 · Cited by 744 · cited 1×
“), while others maintain that it rarely, if ever, occurs (reviewed in”
BackgroundThe size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690 · cited 1×
“First, studies of cough-generated aerosols have shown that human coughs produce a tremendous range of particle sizes, ranging from less than 100 nm to visible drops larger than a millimeter [18,19,20,21].”
BackgroundMilton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
Aerosol transmission of influenza A virus: a review of new studies
Tellier, R. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0302.focus · Cited by 589 · cited 1×
“The likelihood of the airborne transmission of influenza virus by infectious aerosols is particularly unclear, with some investigators concluding that airborne transmission is a key route (reviewed in [1,2,3]), while others maintain that it rarely, if ever, occurs (reviewed in [4]).”
Background
Research works printed but not linked: 1
- Cao G Blachere FM Lindsley WG Chen BT 2010 Laboratory study on sampling and detection of airborne influenza virus [abstract]. In: AAAR 29th Annual Conference; Oct. 25–29; Portland, OR. American Association for Aerosol Research 1E.6
Cited by
Items 201–300 of 439
Procedimientos endoscópicos y pandemia COVID19. Consideraciones básicas
Regino, W. O., Zuleta, M. A. G., Arango, L. A. Á., Morales, O. F. R., Fernández, H. M., Riveros, J., Junca, E. G., Ballén-Párraga, H., Rodríguez, A., Ovalle, L. F. P., et al. (2020) · Revista Colombiana de Gastroenterología · doi:10.22516/25007440.526 · Cited by 27
Qiao, Y., Yang, M., Marabella, I. A., McGee, D. A. J., Olson, B. A., Torremorell, M., & Hogan, C. J. (2021) · Indoor Air · doi:10.1111/ina.12847 · Cited by 20
Impact of washing cycles on the performances of face masks
Charvet, A., Bardin‐Monnier, N., Thomas, D., Dufaud, O., Pfrimmer, M., Barrault, M., Bourrous, S., Mocho, V., Ouf, F. X., Poirier, S., et al. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105914 · Cited by 20
Fennelly, K. P., Acuña-Villaorduña, C., Jones‐López, E. C., Lindsley, W. G., & Milton, D. K. (2019) · CHEST Journal · doi:10.1016/j.chest.2019.10.012 · Cited by 21
“Similarly, with patients with influenza, we sometimes observed patients with negative nasopharyngeal swabs who had positive cough aerosols.(15) These observations and the development of increasingly sensitive molecular markers suggest the potential of cough or breath aerosols to be used as specimens to diagnose diseas…”
BackgroundSelf-citationSantarpia, J. L., Klug, E., Ravnholdt, A. R., & Kinahan, S. (2023) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2023.2197825 · Cited by 21
Bioaerosols and Airborne Transmission in the Dental Clinic
Allison, J. R., Tiede, S., Holliday, R., Durham, J., & Jakubovics, N. S. (2024) · International Dental Journal · doi:10.1016/j.identj.2024.09.026 · Cited by 21
Cao, G., Liu, S., Boor, B. E., & Novoselac, A. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1316383 · Cited by 18
Self-citationWedel, J., Steinmann, P., Štrakl, M., Hriberšek, M., & Ravnik, J. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09613-7 · Cited by 20
AlRayess, S., Sleiman, A., Alameddine, I., Fayad, A. G. A., Matar, G. M., & El‐Fadel, M. (2022) · Air Quality Atmosphere & Health · doi:10.1007/s11869-022-01222-y · Cited by 18
Virus transport and infection evaluation in a passenger elevator with a COVID ‐19 patient
Du, C., & Chen, Q. (2022) · Indoor Air · doi:10.1111/ina.13125 · Cited by 19
Omerzo, B., Žakula, T., & Glicksman, L. R. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112588 · Cited by 17
MEASUREMENT OF COUGH DROPLET DEPOSITION USING THE COUGH MACHINE
OGATA, M., Ichikawa, M., Tsutsumi, H., Ariga, T., Hori, S., & Tanabe, S. (2018) · Journal of Environmental Engineering (Transactions of AIJ) · doi:10.3130/aije.83.57 · Cited by 17
Zhou, B., Liu, T., Yi, S.-Q., Huang, Y., Guo, Y., Huang, S., Zhou, C., Zhou, R., & Cao, H. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph191610446 · Cited by 17
“It has also been shown that the majority of sporadic viral RNA from coughing in influenza patients is contained in particles in the respirable size range [34].”
BackgroundWestern Cold and Flu (WeCoF) aerosol study – preliminary results
Savory, E., Lin, W. E., Blackman, K., Roberto, M. C., Cuthbertson, L. R., Scott, J. A., & Mubareka, S. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-563 · Cited by 20
“For infected individuals, significant influenza RNA also appears to be contained in droplets with diameters in the respirable size range - 35% of influenza RNA was found in droplets of greater than 4 μm diameter, 23% in droplets of 1 to 4 μm diameter and 42% in droplets of less than 1 μm diameter [23] - and symptomati…”
BackgroundInvestigating the airborne transmission pathway - different approaches with the same objectives
Tang, J. W.-T. (2015) · Indoor Air · doi:10.1111/ina.12175 · Cited by 19
Bourrous, S., Barrault, M., Mocho, V., Poirier, S., Bardin‐Monnier, N., Charvet, A., Thomas, D., Bescond, A., Fouqueau, A., Macé, T., et al. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.200615 · Cited by 18
“Furthermore, Lindsley et al. (2010) collected cough-generated particles produced by individuals with influenza like symptoms and concluded that the virus was present in the droplets, whatever their size.”
BackgroundEffect of ceiling fan in mitigating exposure to airborne pathogens and COVID-19
Pandey, B., Saha, S. K., & Banerjee, R. (2023) · Indoor and Built Environment · doi:10.1177/1420326x231154011 · Cited by 18
“As compared to the nasal cavity and trachea, when the virus accumulates in the alveoli, small doses can cause infection.(80) In contrast to sneezing and coughing, finer aerosol particles <1.”
BackgroundAn efficient virus aerosol sampler enabled by adiabatic expansion
Yu, H., Afshar‐Mohajer, N., Theodore, A., Lednicky, J. A., Fan, Z. H., & Wu, C. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2018.01.001 · Cited by 18
Preparation of antibacterial non-woven AgNCs@PP-g-PAA via radiation method
Han, F., Wang, W.-R., Li, D., Xu, S., Su, Y., Lin, L., Lu, M., Li, J., & Li, L. (2023) · Nuclear Science and Techniques · doi:10.1007/s41365-023-01292-2 · Cited by 15
Li, H., Liu, M., Kong, X., Wang, L., Li, J., & Fan, M. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.112523 · Cited by 16
Indoor air sampling for detection of viral nucleic acids
Justen, L. J., Grimm, S. L., Esvelt, K. M., & Bradshaw, W. J. (2025) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2025.106549 · Cited by 19
High fidelity modeling of aerosol pathogen propagation in built environments with moving pedestrians
Löhner, R., & Antil, H. (2021) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3428 · Cited by 16
“Compare these numbers and consider that as many as 3000 organisms can be produced by talking for 5 minutes or a single cough, with sneezing producing many more [43,57,58,69,75].”
BackgroundInnovations in modeling influenza virus infections in the laboratory
Gustin, K. M., Belser, J. A., Katz, J. M., Tumpey, T. M., & Maines, T. R. (2012) · Trends in Microbiology · doi:10.1016/j.tim.2012.03.006 · Cited by 15
“Influenza virus can be detected in exhaled aerosols of this size from people but has been largely limited to detection of viral RNA, demonstrating the presence of influenza viral material in respirable aerosol particles and the need to improve methods to preserve virus viability in sampled aerosols [16, 61] .”
BackgroundMethodWagner, J., Macher, J. M., Chen, W., & Kumagai, K. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315555 · Cited by 14
“Field data instead show higher SARS- CoV-2 and influenza RNA counts in finer fractions [47,58], however, so the relative lack of large infectious particles may suggest that upper respiratory modes (O1 and O2) are not as important for SARS-CoV-2.”
BackgroundTransport and evaporation of exhaled respiratory droplets: An analytical model
Cavazzuti, M., & Tartarini, P. (2023) · Physics of Fluids · doi:10.1063/5.0170545 · Cited by 17
Influenza virus infection and aerosol shedding kinetics in a controlled human infection model
Shetty, N., Shephard, M. J., Rockey, N. C., Macenczak, H., Traenkner, J. J., Danzy, S., Vargas-Maldonado, N., Arts, P. J., Sage, V. L., Anderson, E. J., et al. (2024) · Journal of Virology · doi:10.1128/jvi.01612-24 · Cited by 14
“Other published attempts at collecting infectious influenza virus from exhaled breath aerosols have also yielded low detection rates and/or low amounts of infectious virus (31–35).”
Bathula, S., Anand, S., Thajudeen, T., Mayya, Y. S., Chaudhury, P., & Shashank, C. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.200547 · Cited by 15
“Despite numerous studies on the cough droplet size distribution (Duguid, 1946; Loudon and Roberts, 1967; Papineni and Rosenthal, 1997; Morawska et al., 2009; Lindsley et al., 2010; Johnson et al., 2011; Lindsley et al., 2012), there is significant variation in the published data.”
BackgroundThe aerobiological pathway of natural respiratory viral aerosols
Santarpia, J. L., Reid, J. P., Wu, C., Lednicky, J. A., & Oswin, H. P. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117557 · Cited by 14
Ahrenholz, S. H., Brueck, S., Rule, A. M., Noti, J. D., Noorbakhsh, B., Blachère, F. M., de Perio, M. A., Lindsley, W. G., Shaffer, R. E., & Fisher, E. M. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1486509 · Cited by 14
Self-citationPulit-Penaloza, J. A., Belser, J. A., Tumpey, T. M., & Maines, T. R. (2019) · Applied and Environmental Microbiology · doi:10.1128/aem.00210-19 · Cited by 15
“Mathematical modeling studies (8) and detection of influenza RNA 71 in the air collected from spaces occupied by infected individuals (9-16), or in air directly 72 exhaled from patients (17-24), support a role for aerosol transmission in the spread of 73”
BackgroundWu, J., & Zha, P. (2020) · Preprints.org · doi:10.20944/preprints202003.0246.v1 · Cited by 14
Airborne Disease Propagation on Large Scale Social Contact Networks
Shahzamal, Jurdak, R., Arablouei, R., Kim, M., Thilakarathna, K., & Mans, B. (2017) · International Workshop on Social Sensing (SocialSens) · doi:10.1145/3055601.3055604 · Cited by 13
“Droplets above 5 μ m settled down to ground quickly.”
BackgroundSustainability of SARS-CoV-2 in aerosols: should we worry about airborne transmission?
Romano-Bertrand, S., Aho, S., Grandbastien, B., Gehanno, J.-F., & Lepelletier, D. (2020) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.06.018 · Cited by 13
“Furthermore, even if influenza is considered as a droplet-mediated disease, a study showed that 43% of viral RNA emitted from patients was carried on particles of <1 mm in diameter, suggesting the potential for airborne transmission [7].”
Agarwal, A., Fernando, S. M., Honarmand, K., Bakaa, L., Brar, S., Granton, D., Chaudhuri, D., Chetan, D., Hu, M., Basmaji, J., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-040616 · Cited by 13
Haas, R., Şekercioğlu, F., Meldrum, R. J., & Young, I. (2021) · Food Protection Trends · doi:10.4315/1541-9576-41.5.454 · Cited by 13
Mirza, S., Niwalkar, A., Gupta, A., Gautam, S., Anshul, A., Bherwani, H., Biniwale, R. B., & Kumar, R. (2022) · Gondwana Research · doi:10.1016/j.gr.2022.03.013 · Cited by 14
Chow, V. T. K., Tay, D. J. W., Chen, M. I.-C., Tang, J. W.-T., Milton, D. K., & Tham, K. W. (2023) · Viruses · doi:10.3390/v15102033 · Cited by 13
“Viral RNA copy numbers were signifi-Viruses cantly greater in the fine fraction than in the coarse fraction, consistent with the results obtained from other studies [3,7,19].”
BackgroundResultInfluentialReyes, C. G., & Frey, M. W. (2017) · Journal of Applied Polymer Science · doi:10.1002/app.44759 · Cited by 13
Li, Y., Wu, C., Cao, G., Guan, D., & Zhan, C. (2021) · International Journal of Environmental Health Research · doi:10.1080/09603123.2021.1910629 · Cited by 14
“2012)(Lai and Wong 2011) (Lindsley et al. 2010)(Morawska et al.”
BackgroundSelf-citationSpatial Distribution of Exhalation Droplets in the Bus in Different Seasons
Duan, W., Mei, D., Li, J., Liu, Z., Jia, M., & Hou, S. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.200478 · Cited by 13
“transmission routes, aerosols are more capable of carrying viruses and can spread farther in the environment (Xie et al., 2007; Lindsley et al., 2010).”
Oksanen, L., Sanmark, E., Sofieva, S., Rantanen, N., Lahelma, M., Anttila, V., Lehtonen, L., Atanasova, N. S., Pesonen, E., Geneid, A., et al. (2022) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.14022 · Cited by 13
Effectiveness of facemasks for pediatric populations against submicron-sized aerosols
Guha, S., Mejía-Alfaro, A., Hariharan, P., & Myers, M. R. (2015) · American Journal of Infection Control · doi:10.1016/j.ajic.2015.03.032 · Cited by 15
Liu, H., Liu, Z., Yao, G., Dong, Z., Jiang, C., Liu, J., Rong, R., He, J., Hu, C., Li, S., et al. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.137601 · Cited by 12
Thomas, R. E. (2016) · Vaccine · doi:10.1016/j.vaccine.2016.04.096 · Cited by 13
“85 × 105) on plaque assays from nasopharyngeal swabs [8].”
BackgroundNatural protection of ocular surface from viral infections – A hypothesis
Zimmerman, K. T., Kearns, F. L., & Tzekov, R. T. (2020) · Medical Hypotheses · doi:10.1016/j.mehy.2020.110082 · Cited by 12
“Although studies with coronavirus are not available, one study measured influenza virus in cough samples and found that 35% of the influenza RNA was isolated from particles> 4 μm diameter, while 23% of influenza RNA was isolated from particles 1 to 4 μm diameter, and 42% in particles< 1 μm [54].”
Bacteriophages as surrogates for the study of viral dispersion in open air
Machado, G. T., Pinto, C. R. D. C., da Fonseca, L. A. V., Ramos, T. C. D. S., Paggi, T. F. P., & Spira, B. (2021) · Archives of Microbiology · doi:10.1007/s00203-021-02382-8 · Cited by 13
“However, several studies have shown that humans produce infectious influenza droplets containing both aerosols (small particles) and larger droplets (Bischoff et al. 2013; Fabian et al. 2008; Lindsley et al. 2010).”
BackgroundDevelopment of an optimized method for the detection of airborne viruses with real-time PCR analysis
Ziros, P. G., Kokkinos, P. A., Legaki, E., & Vantarakis, A. (2011) · Virology Journal · doi:10.1186/1743-422x-8-369 · Cited by 11
“The question of airborne transmission is especially important for the waste treatment plant workers and for healthcare workers where patients tend to congregate during for example influenza season [4].”
BackgroundElectrochemical Detection of Airborne Influenza Virus using Air Sampling System
Kim, H., Min, J., Park, G., Shin, D., Sung, G., Kim, T., & Lee, M. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2018.06.0221 · Cited by 12
“The collection efficiency was measured using 10 µm particles because the overall size of airborne hydrosols containing the cluster of virus ranges from 1 to 10 µm (Lindsley et al. , 2010).”
Cummings, K. J., Martin, S. B., Lindsley, W. G., Othumpangat, S., Blachère, F. M., Noti, J. D., Beezhold, D. H., Roidad, N., Parker, J. E. S., & Weissman, D. N. (2014) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiu127 · Cited by 12
Self-citationMask Is a Double-edged Sword in the Fight Against COVID-19 PandemicPreprint
Wu, J., & Zha, P. (2020) · SSRN Electronic Journal · doi:10.2139/ssrn.3563851 · Cited by 12
Girolamo, P. D. (2020) · Bulletin of Atmospheric Science and Technology · doi:10.1007/s42865-020-00024-3 · Cited by 12
Onianwa, O., Garratt, I., Carter, J., Spencer, A., Verlander, N. Q., Pottage, T., & Bennett, A. (2022) · Applied and Environmental Microbiology · doi:10.1128/aem.00764-22 · Cited by 11
“The number of viral particles in influenza aerosols has been estimated to be around 10 to 100 viral particles, based on a measurements of viral RNA (17, 18).”
BackgroundGao, J. Q., Yu, M., Xu, Y., He, L., Zeng, L., Cao, G., & Wei, X. (2024) · Building and Environment · doi:10.1016/j.buildenv.2024.112019 · Cited by 11
Self-citationLee, W.-N., Yoo, H. J., Nguyen, K. H., Baek, C., & Min, J. (2019) · The Analyst · doi:10.1039/c9an00896a · Cited by 11
Cournoyer, A., Grand’Maison, S., Lonergan, A.-M., Lessard, J., Chauny, J., Castonguay, V., Marquis, M., Frégeau, A., Huard, V., Garceau-Tremblay, Z., et al. (2020) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2020.06.037 · Cited by 13
Aodeng, S., Wang, W., Chen, Y., Feng, G., Wang, J., Lv, W., Yang, H., Ding, X., Song, K., Zhao, S., et al. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezaa312 · Cited by 11
Tao, C., Chen, J., Hsu, B., Koner, S., Hung, T.-C., Han-ming, W., & Rathod, J. (2021) · Antibiotics · doi:10.3390/antibiotics10080917 · Cited by 12
Hall, S., Johnson, P., Bailey, C., Gould, Z., White, R. M., & Crook, B. (2022) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxac047 · Cited by 11
“, 2013) which was based on flow rate measurements of coughs from 47 human subjects with influenza (Lindsley et al., 2010).”
BackgroundYang, Z., Wang, Q., Zhao, L., & Long, E. (2022) · Indoor and Built Environment · doi:10.1177/1420326x211052603 · Cited by 12
Occupational exposure monitoring of airborne respiratory viruses in outpatient medical clinics
Vass, W. B., Shirkhani, A., Washeem, M., Shankar, S. N., Zhang, Y., Moquin, T. L., Messcher, R. L., Jansen, M. D., Clugston, J. R., Walser, M. P., et al. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2403580 · Cited by 11
“Lindsley et al. (2010) detected only 23% of influenza RNA in 1–4 l m particles using BC-251 samplers, but another 42% was collected in particles < 1 l m, which is likewise pertinent to infections in the lower respiratory tract.”
Microbial Aerosols in Livestock Farming Environment: A Threat That Cannot Be Ignored
Lu, H., Xie, Y., Chen, L., Song, Y., Zhang, L., Li, R., Nie, X., Liu, Y., Zhu, G., Ding, X., et al. (2025) · Veterinary Sciences · doi:10.3390/vetsci12121147 · Cited by 11
McKay, B., Ebell, M. H., Dale, A. P., Shen, Y., & Handel, A. (2020) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.2020.0496 · Cited by 14
Aerosols, Droplets, and Airborne Spread: Everything you could possibly want to know
Morgenstern, J. (2020) · First10EM blog · doi:10.51684/firs.17317 · Cited by 10
Li, Y., Liu, J., Yang, Z., Yu, J., Xu, C., Zhu, A., Zhang, H., Yang, X., Zhao, X., Ren, M., et al. (2021) · Emerging infectious diseases · doi:10.3201/eid2709.202035 · Cited by 10
Electrostatic Sampling of Patient Breath for Pathogen Detection: A Pilot Study
Ladhani, L., Pardon, G., Moons, P., Goossens, H., & van der Wijngaart, W. (2020) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2020.00040 · Cited by 11
“Exhaled Virus Capture in Literature Table 2 summarizes results from previous studies, which emphasize the minute amounts of pathogens present in exhaled breath (Fennelly et al., 2004; Huynh et al., 2007; Fabian et al., 2008; Stelzer-Braid et al., 2009; Lindsley et al., 2010; St George et al., 2010).”
BackgroundBranch‐Elliman, W., Price, C. S., Bessesen, M. T., & Perl, T. M. (2015) · Current Environmental Health Reports · doi:10.1007/s40572-015-0059-7 · Cited by 11
“” 50 Forty-two percent of the viral RNA was contained in particles less than one micron in diameter and 23% in an intermediate size range.(50)”
Background‘Led by the science’, evidence gaps, and the risks of aerosol transmission of SARS-COV-2
Simonds, A. K. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.05.019 · Cited by 11
“Lindsley et al.10 measured the presence of influenza virus in aerosol particles from coughs in infected individuals and found that much of the viral RNA was contained in particles in the respirable range 35% in particles less than 4 microns, 23% in particles of 1 4 mm and 42% in particles less than 1 mm.”
BackgroundFiltration and Breathability of Nonwoven Fabrics Used in Washable Masks
Bement, T. W., Downey, D. J., Mitros, A., Lau, R., Sipkens, T. A., Songer, J., Alexander, H., Ostrom, D., Nikookar, H., & Rogak, S. N. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220044 · Cited by 11
“In cough droplets of influenza patients, Lindsley et al. (2010) found that 42% of the influenza RNA was contained in particles < 1 µm aerodynamic diameter, 23% in particles 1–4 µm, and 35% in particles > 4 µm.”
BackgroundShankar, S. N., Vass, W. B., Lednicky, J. A., Logan, T. D., Messcher, R. L., Eiguren-Fernandez, A., Amanatidis, S., Sabo‐Attwood, T., & Wu, C. (2023) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2023.106263 · Cited by 9
Zhou, X.-Y., Liu, X., Zhao, H., Guo, G., Jiang, X., Liu, S., Sun, X., & Yang, H. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06213-7 · Cited by 11
“The potential for airborne transmission of influenza viruses depends in part on the amount of aerosolized virus to which people are exposed [59, 109].”
Hunziker, P. (2021) · BMJ Open · doi:10.1136/bmjopen-2020-047772 · Cited by 9
“…number in the turbulent regime), favouring air mixing and thus potentially transporting aerosol-loaded air from non-breathing zones towards breathing zones; therefore, the benefit of just increasing ventilation has limitations that depend on the specific characteristics of a room and A/C system.”
Airborne Transmission of SARS-CoV-2: The Contrast between Indoors and Outdoors
Beggs, C. B., Abid, R., Motallebi, F., Samad, A., Venkatesan, N., & Avital, E. J. (2024) · Fluids · doi:10.3390/fluids9030054 · Cited by 11
Jia, Y., Xiang, Y., Guo, S., Guo, L., Guo, L., Zhu, C., Zhang, Y., Zhang, L., & Long, E. (2021) · Environmental Science and Pollution Research · doi:10.1007/s11356-021-14495-0 · Cited by 9
“Relevant experimental studies have been carried out (Blachere et al. 2009; Lindsley et al. 2010a, b; Noti et al. 2012; Yang et al. 2011), testing the onetime removal efficiency of different grades of filters for infectious droplet nuclei with particle sizes ranging from 0.3 to 10 μ.”
BackgroundInfluentialYou, S., Chen, S., Wang, C.-H., & Liao, C. (2013) · Journal of Epidemiology · doi:10.2188/jea.je20120031 · Cited by 9
Cowling, B. J. (2012) · Clinical Infectious Diseases · doi:10.1093/cid/cis240 · Cited by 12
“Some studies have reported that influenza virus can be detected in both large and small particles from exhaled breaths and coughs [10, 11] and in the air in medical clinics during epidemic periods [12].”
BackgroundControlled human influenza infection reveals heterogeneous expulsion of infectious virus into air
Vargas-Maldonado, N., Shetty, N., Ferreri, L. M., Pauly, M. D., Patatanian, K., Danzy, S., Shephard, M. J., VanInsberghe, D., Vu, M. N., Campbell, A. J., et al. (2026) · Cell · doi:10.1016/j.cell.2026.02.025 · Cited by 11
The Optimization of Methods for the Collection of Aerosolized Murine Norovirus
Boles, C., Brown, G., Park, J. H., & Nonnenmann, M. W. (2020) · Food and Environmental Virology · doi:10.1007/s12560-020-09430-4 · Cited by 8
Treanor, J. J. (2023) · Springer eBooks · doi:10.1007/978-1-4939-9544-8_19-2 · Cited by 10
Dynamic Regimes of El Niño Southern Oscillation and Influenza Pandemic Timing
Oluwole, O. S. A. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00301 · Cited by 8
“Transmission of influenza viruses in human populations occurs through aerosols (6), droplets (7), or direct contact with infected secretions (8), but aerosol transmission is the most effective (9).”
BackgroundThe effect of climbing chalk powder on the infectivity of human coronavirus OC43
Owen, L., Laird, K., & Shivkumar, M. (2021) · Letters in Applied Microbiology · doi:10.1111/lam.13466 · Cited by 8
“Previous work on influenza demonstrated that the infectious viral load of one cough was 5 plaque-forming units ml 1 (Lindsley et al. 2010), suggesting that 5 log10 TCID50 per ml may be greater than that encountered under realistic conditions.”
BackgroundThe possible role of the surface active substances (SAS) in the airborne transmission of SARS-CoV-2
Ciglenečki, I., Orlović-Leko, P., Vidović, K., & Tasić, V. (2021) · Environmental Research · doi:10.1016/j.envres.2021.111215 · Cited by 8
Submerged leaves of live indoor foliage plants adsorb H1N1 influenza virus from suspension
Song, H. J., Yang, S. W., Jo, J. W., Choi, Y., Lee, I., Lee, B. U., Lee, S. H., Kim, H.-H., Kim, K. J., & Kim, H. J. (2023) · Plant Signaling & Behavior · doi:10.1080/15592324.2022.2163869 · Cited by 8
Gut, I. M., Bartlett, R. A., Yeager, J. J., Leroux, B. M., Ratnesar-Shumate, S. A., Dabisch, P. A., & Karaolis, D. K. R. (2016) · Applied and Environmental Microbiology · doi:10.1128/aem.03989-15 · Cited by 8
“Furthermore, patients experiencing a respiratory infection have been shown to generate particles that predominantly exist in the respirable range, 10 m (41, 42), which can be widely disseminated via breathing, coughing, and sneezing (41).”
BackgroundAerosol generation during coughing: an observational study
Sanmark, E., Oksanen, L., Rantanen, N.-K., Lahelma, M., Anttila, V.-J., Lehtonen, L., Hyvärinen, A., & Geneid, A. (2022) · The Journal of Laryngology & Otology · doi:10.1017/s0022215122001165 · Cited by 8
Relative Humidity-Dependent Phase Transitions in Submicron Respiratory Aerosols
Gibbons, A. M., & Ohno, P. E. (2024) · The Journal of Physical Chemistry A · doi:10.1021/acs.jpca.4c00691 · Cited by 8
Brass, A., Shoubridge, A. P., Crotty, M., Morawska, L., Bell, S. C., Qiao, M., Woodman, R. J., Whitehead, C., Inacio, M. C. S., Miller, C. L., et al. (2021) · BMC Infectious Diseases · doi:10.1186/s12879-021-06659-7 · Cited by 7
“While the overall contribution of this transmission route remains uncertain, an airborne component of COVID-19 transmission would be consistent with other respiratory viruses, such as SARSCoV-1, Middle Eastern respiratory syndrome coronavirus (MERS-CoV), and influenza [9, 10].”
BackgroundWang, Y., Wei, J., Gao, C. X., Jin, T., & Liu, L. (2023) · Building Simulation · doi:10.1007/s12273-022-0982-0 · Cited by 7
“However, fine droplets have been proved as important carriers of influenza viruses (Lindsley et al. 2010; Milton et al. 2013) and, recently, of SARS-CoV-2 (Coleman et al.”
BackgroundMethodXu, N., Tang, X., Wang, X., Cai, M., Liu, X., Lu, X., Hu, S., Gu, M., Hu, J., Gao, R., et al. (2023) · Virology · doi:10.1016/j.virol.2023.109926 · Cited by 8
Comparison of the performance of aerosol sampling devices with aerosols containing Ebola virus
Schuit, M. A., Taylor, J. R., Dunning, R., Miller, D., Freeburger, D., Faisca, L., Wahl‐Jensen, V., & Dabisch, P. A. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2020.1867310 · Cited by 7
“The NIOSH BC251 was developed as an aerosol sampler for field and clinical settings and has been used successfully in several such applications (Bertran et al. 2017; Lindsley et al. 2010).”
MethodA review of the COVID-19 pandemic and its interaction with environmental media
Yuvaraj, M., & Lakshminarayanan, I. (2021) · Environmental Challenges · doi:10.1016/j.envc.2021.100040 · Cited by 8
“Similarly, coughing also has a dual range of 0.6 to 16 𝜇m Morawska et al., 2009 ; Yang et al., 2007 ; Lindsley et al., 2010 ) and 40 o 125 𝜇m.”
InfluentialBao, L., Zhang, G. L., Lei, Q., Li, Y., Li, X., Hwu, Y., & Yi, J. M. (2015) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2015.07.050 · Cited by 7
Work environment risks for health care workers with cystic fibrosis
Bell, S. C., Armstrong, D., Harrington, G. A., Jardine, L. A., Divakaran, R., Loff, B., Middleton, P. G., McDonald, T., Rowland, K., Wishart, M., et al. (2018) · Respirology · doi:10.1111/resp.13404 · Cited by 7
A deterministic pathogen transmission model based on high-fidelity physics
Löhner, R., Antil, H., Giménez, J. M., Idelsohn, S. R., & Oñate, E. (2022) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2022.114929 · Cited by 7
Use of Virtual Impactor (VI) Technology in Biological Aerosol Detection
Ho, J. (2011) · KONA Powder and Particle Journal · doi:10.14356/kona.2011006 · Cited by 7
N95 Respirators vs Medical Masks in Outpatient Settings
McDiarmid, M. A., Harrison, R., & Nicas, M. (2020) · JAMA · doi:10.1001/jama.2019.20905 · Cited by 7
Public Health Intervention Framework for Reviving Economy Amid the COVID-19 Pandemic: A ConceptPreprint
Wu, J., & Zha, P. (2020) · SSRN Electronic Journal · doi:10.2139/ssrn.3571775 · Cited by 7
“Other studies showed that respiratory particles by influenza patients were produced while breathing or coughing, but not both maneuvers side-by-side [29, 30, 31].”
Aeronautics in dentistry: Navigating oral health challenges in zero gravity
Doshi, D. J., & Tamgadge, S. (2024) · Journal of Academy of Dental Education · doi:10.25259/jade_36_2024 · Cited by 10
Xu, J., Zhai, H., So, L. K., Wang, C., & Guo, H. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.138446 · Cited by 7
Air-liquid interface model for influenza aerosol exposure in vitro
Seibert, B., Cáceres, C. J., Gay, L. C., Shetty, N., Faccin, F. C., Carnaccini, S., Walters, M. S., Marr, L. C., Lowen, A. C., Rajão, D. S., et al. (2025) · Journal of Virology · doi:10.1128/jvi.00619-25 · Cited by 7
Choi, N., Bivolarova, M. P., & Wargocki, P. L. (2025) · Building and Environment · doi:10.1016/j.buildenv.2025.113314 · Cited by 6
Metadata
- Authors
- Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., & Beezhold, D. H.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- West Virginia University (US)
- Corresponding author
- Lindsley, William G.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2010-11-30
- Volume
- 5
- Issue
- 11
- Pages
- e15100
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC2994911
- OpenAlex
- W2040363935
- Cited by
- 423
- References
- 23
- Citations by year
- 2026: 14 · 2025: 22 · 2024: 22 · 2023: 29 · 2022: 32 · 2021: 77 · 2020: 72 · 2019: 12 · 2018: 18 · 2017: 20 · 2016: 15 · 2015: 22 · 2014: 15 · 2013: 21 · 2012: 16
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion, public-domain)
- PubMed Central (publishedVersion, public-domain)
- PubMed (publishedVersion)
- The Research Repository @ WVU (West Virginia University) (submittedVersion, public-domain)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Funders
- U.S. Environmental Protection Agency
- Centers for Disease Control and Prevention
- U.S. Public Health Service (DW7592259701)
- National Institute for Occupational Safety and Health
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Epidemiology › Influenza Virus Research Studies
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Keywords
- influenza virus, airborne transmission, cough aerosols, aerosol particle size, respiratory droplets, influenza-like illness, viral RNA detection, respiratory infection transmission
- MeSH terms
- Adolescent, Adult, Aerosols, Air Microbiology, Cough, Female, Humans, Influenza, Human, Male, Orthomyxoviridae, RNA, Viral, Viral Matrix Proteins, Reverse Transcriptase Polymerase Chain Reaction, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.