Gait Detection in Children with and without Hemiplegia Using Single-Axis Wearable Gyroscopes
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this work, we develop a novel gait phase detection algorithm based on a hidden Markov model, which uses data from foot-mounted single-axis gyroscopes as input. We explore whether the proposed gait detection algorithm can generate equivalent results as a reference signal provided by force sensitive resistors (FSRs) for typically developing children (TD) and children with hemiplegia (HC). We find that the algorithm faithfully reproduces reference results in terms of high values of sensitivity and specificity with respect to FSR signals. In addition, the algorithm distinguishes between TD and HC and is able to assess the level of gait ability in patients. Finally, we show that the algorithm can be adapted to enable real-time processing with high accuracy. Due to the small, inexpensive nature of gyroscopes utilized in this study and the ease of implementation of the developed algorithm, this work finds application in the on-going development of active orthoses designed for therapy and locomotion in children with gait pathologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robot assisted gait training with Active Leg Exoskeleton (ALEX)
Banala, S. K., Kim, S. H., Agrawal, S. K., & Scholz, J. P. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2008280 · Cited by 751
Gait phase analysis based on a Hidden Markov Model
Bae, J., & Tomizuka, M. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2011.03.003 · Cited by 106 · cited 2×
“…of the sural nerve [24]; (ii) probabilistic Bayesian networks implemented on video data [25]; and, finally, (iii) hidden Markov models (HMMs) used to identify the most probable gait phase sequence from shoes instrumented with pressure sensors [21] or from single-axis gyroscope data [23].”
BackgroundMethod
Cited by
Gait Partitioning Methods: A Systematic Review
Taborri, J., Palermo, E., Rossi, S., & Cappa, P. (2016) · Sensors · doi:10.3390/s16010066 · Cited by 361
Self-citationWearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
“[3] used angular velocity of the foot in the sagittal plane as input to the HMM, while Ref.”
MethodMannini, A., Trojaniello, D., Cereatti, A., & Sabatini, A. (2016) · Sensors · doi:10.3390/s16010134 · Cited by 242
“Although no classification tests were conducted, Abaid and colleagues found significant differences in the duration of the gait phases between 10 healthy and 10 hemiplegic children using IMU data [14].”
BackgroundWearable Inertial Sensors and Their Applications
Tamura, T. (2014) · Wearable Sensors · doi:10.1016/b978-0-12-418662-0.00024-6 · Cited by 19
Metadata
- Authors
- Abaid, N., Cappa, P., Palermo, E., Petrarca, M., & Porfiri, M.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-09-04
- Volume
- 8
- Issue
- 9
- Pages
- e73152
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2074784720
- Cited by
- 89
- References
- 2
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.