The Landscape of Inappropriate Laboratory Testing: A 15-Year Meta-Analysis
Open accessThe DOI matches its Crossref record; 73 of the 75 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Laboratory testing is the single highest-volume medical activity and drives clinical decision-making across medicine. However, the overall landscape of inappropriate testing, which is thought to be dominated by repeat testing, is unclear. Systematic differences in initial vs. repeat testing, measurement criteria, and other factors would suggest new priorities for improving laboratory testing. METHODS: A multi-database systematic review was performed on published studies from 1997-2012 using strict inclusion and exclusion criteria. Over- vs. underutilization, initial vs. repeat testing, low- vs. high-volume testing, subjective vs. objective appropriateness criteria, and restrictive vs. permissive appropriateness criteria, among other factors, were assessed. RESULTS: Overall mean rates of over- and underutilization were 20.6% (95% CI 16.2-24.9%) and 44.8% (95% CI 33.8-55.8%). Overutilization during initial testing (43.9%; 95% CI 35.4-52.5%) was six times higher than during repeat testing (7.4%; 95% CI 2.5-12.3%; P for stratum difference <0.001). Overutilization of low-volume tests (32.2%; 95% CI 25.0-39.4%) was three times that of high-volume tests (10.2%; 95% CI 2.6-17.7%; P<0.001). Overutilization measured according to restrictive criteria (44.2%; 95% CI 36.8-51.6%) was three times higher than for permissive criteria (12.0%; 95% CI 8.0-16.0%; P<0.001). Overutilization measured using subjective criteria (29.0%; 95% CI 21.9-36.1%) was nearly twice as high as for objective criteria (16.1%; 95% CI 11.0-21.2%; P = 0.004). Together, these factors explained over half (54%) of the overall variability in overutilization. There were no statistically significant differences between studies from the United States vs. elsewhere (P = 0.38) or among chemistry, hematology, microbiology, and molecular tests (P = 0.05-0.65) and no robust statistically significant trends over time. CONCLUSIONS: The landscape of overutilization varies systematically by clinical setting (initial vs. repeat), test volume, and measurement criteria. Underutilization is also widespread, but understudied. Expanding the current focus on reducing repeat testing to include ordering the right test during initial evaluation may lead to fewer errors and better care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“20%–50% of inpatient laboratory tests are medically unnecessary,2–4”
From SmartAlert - Implementing Machine Learning-Driven Clinical Decision Support for Inpatient Laboratory Utilization Reduction (2026) · cites this paper as [2]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,451
Meta-analysis of Observational Studies in Epidemiology<SUBTITLE>A Proposal for Reporting</SUBTITLE>
Stroup, D. F. (2000) · JAMA · doi:10.1001/jama.283.15.2008 · Cited by 20,623
Crossing the Quality Chasm: A New Health System for the 21st Century
Baker, A. (2001) · BMJ · doi:10.1136/bmj.323.7322.1192 · Cited by 10,736
Wall, A. (2000) · British Journal of Healthcare Management · doi:10.12968/bjhc.2000.6.9.19311 · Cited by 5,903
COMMITTEE ON QUALITY OF HEALTH CARE IN AMERICA
Kohn, L. T., Corrigan, J. M., & Donaldson, M. S. (2000) · Cited by 1,540
Brown, A. B., & Patterson, D. A. (2001) · Cited by 1,390
A User’s Manual For The IOM’s ‘Quality Chasm’ Report
Berwick, D. M. (2002) · Health Affairs · doi:10.1377/hlthaff.21.3.80 · Cited by 704
Missed and delayed diagnoses in the ambulatory setting: a study of closed malpractice claims
Gandhi, T. K., Kachalia, A., Thomas, E. J., Puopolo, A. L., Yoon, C., Brennan, T. A., & Studdert, D. M. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-7-200610030-00006 · Cited by 662
National Costs Of The Medical Liability System
Mello, M. M., Chandra, A., Gawande, A. A., & Studdert, D. M. (2010) · Health Affairs · doi:10.1377/hlthaff.2009.0807 · Cited by 498
Kachalia, A., Gandhi, T. K., Puopolo, A. L., Yoon, C., Thomas, E. J., Griffey, R., Brennan, T. A., & Studdert, D. M. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.06.035 · Cited by 497
Patient Safety At Ten: Unmistakable Progress, Troubling Gaps
Wachter, R. M. (2010) · Health Affairs · doi:10.1377/hlthaff.2009.0785 · Cited by 400
A National Strategy To Put Accountable Care Into Practice
McClellan, M., McKethan, A. N., Lewis, J. L., Roski, J., & Fisher, E. S. (2010) · Health Affairs · doi:10.1377/hlthaff.2010.0194 · Cited by 385
van Walraven, C., & Naylor, C. D. (1998) · JAMA · doi:10.1001/jama.280.6.550 · Cited by 373
Fisher, E. S., Staiger, D. O., Bynum, J. P. W., & Gottlieb, D. J. (2006) · Health Affairs · doi:10.1377/hlthaff.26.1.w44 · Cited by 328
Medicine's Ethical Responsibility for Health Care Reform — The Top Five List
Brody, H. (2010) · New England Journal of Medicine · doi:10.1056/nejmp0911423 · Cited by 294
Bates, D. W., Kuperman, G. J., Rittenberg, E., Teich, J. M., Fiskio, J., Ma’luf, N., Onderdonk, A., Wybenga, D., Winkelman, J., Brennan, T. A., et al. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(98)00410-0 · Cited by 292
Exploring the iceberg of errors in laboratory medicine
Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.022 · Cited by 289
Miyakis, S., Karamanof, G., Liontos, M., & Mountokalakis, T. D. (2006) · Postgraduate Medical Journal · doi:10.1136/pgmj.2006.049551 · Cited by 257
Accountable Care Organizations: Accountable for What, to Whom, and How
Fisher, E. S., & Shortell, S. M. (2010) · JAMA · doi:10.1001/jama.2010.1513 · Cited by 246
Leape, L. L. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.020 · Cited by 220
Health Care Spending and Quality in Year 1 of the Alternative Quality Contract
Song, Z., Safran, D. G., Landon, B. E., He, Y., Ellis, R. P., Mechanic, R. E., Day, M. P., & Chernew, M. E. (2011) · New England Journal of Medicine · doi:10.1056/nejmsa1101416 · Cited by 191
Verstappen, W. H. J. M., van der Weijden, T., Sijbrandij, J., Smeele, I., Hermsen, J., Grimshaw, J., & Grol, R. P. T. M. (2003) · JAMA · doi:10.1001/jama.289.18.2407 · Cited by 160
What Proportion of Common Diagnostic Tests Appear Redundant?
Bates, D. W., Boyle, D. L., Rittenberg, E., Kuperman, G. J., Ma'Luf, N., Menkin, V., Winkelman, J. W., & Tanasijevic, M. J. (1998) · The American Journal of Medicine · doi:10.1016/s0002-9343(98)00063-1 · Cited by 129
Merlani, P., Garnerin, P., Diby, M., Ferring, M., & Ricou, B. (2001) · BMJ · doi:10.1136/bmj.323.7313.620 · Cited by 120
Reducing Unnecessary Inpatient Laboratory Testing in a Teaching Hospital
May, T. A., Clancy, M., Critchfield, J., Ebeling, F., Enriquez, A., Gallagher, C., Genevro, J., Kloo, J., Lewis, P., Smith, R., et al. (2006) · American Journal of Clinical Pathology · doi:10.1309/wp59-ym73-l6ce-gx2f · Cited by 111
(1972) · PubMed Central · Cited by 108
Unnecessary repeat requesting of tests: an audit in a government hospital immunology laboratory
Kwok, J., & Jones, B. M. (2005) · Journal of Clinical Pathology · doi:10.1136/jcp.2004.021691 · Cited by 104
Stewart, B. A., Fernandes, S., Rodriguez-Huertas, E., & Landzberg, M. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2009.001750 · Cited by 92
Surgical Vampires and Rising Health Care Expenditure: Reducing the Cost of Daily Phlebotomy
Stuebing, E. A. (2011) · Archives of Surgery · doi:10.1001/archsurg.2011.103 · Cited by 90
Chen, P., Tanasijevic, M. J., Schoenenberger, R. A., Fiskio, J., Kuperman, G. J., & Bates, D. W. (2003) · American Journal of Clinical Pathology · doi:10.1309/a96xu9yku298hb2r · Cited by 81
To err is human. To misdiagnose might be deadly
Plebani, M., & Lippi, G. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.07.002 · Cited by 54
Mann, K., Hiemke, C., Schmidt, L. G., & Bates, D. W. (2006) · Therapeutic Drug Monitoring · doi:10.1097/01.ftd.0000189897.16307.65 · Cited by 54
Evaluating the Appropriateness of Digoxin Level Monitoring
Cañas, F., Tanasijevic, M. J., Ma'luf, N., & Bates, D. W. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.4.363 · Cited by 51
Were, M. C., Shen, C., Tierney, W. M., Mamlin, J. J., Biondich, P. G., Li, X., Kimaiyo, S., & Mamlin, B. W. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2010.005520 · Cited by 50
Niès, J., Colombet, I., Zapletal, E., Gillaizeau, F., Chevalier, P., & Durieux, P. (2010) · BMC Health Services Research · doi:10.1186/1472-6963-10-70 · Cited by 44
Less utilization of the clinical laboratory produces disproportionately small true cost reductions
Winkelman, J. W. (1984) · Human Pathology · doi:10.1016/s0046-8177(84)80002-7 · Cited by 43
The Role of Routine Assays of Serum Amylase and Lipase for the Diagnosis of Acute Abdominal Pain
Sutton, P. A., Humes, D. J., Purcell, G., Smith, J. K., Whiting, F., Wright, T., Morgan, L., & Lobo, D. N. (2009) · Annals of The Royal College of Surgeons of England · doi:10.1308/003588409x392135 · Cited by 43
Low adherence to national guidelines for thyroid screening in Down syndrome
Fergeson, M. A., Mulvihill, J. J., Schaefer, G. B., DeHaai, K. A., Piatt, J., Combs, K., Bright, B. C., & Neas, B. R. (2009) · Genetics in Medicine · doi:10.1097/gim.0b013e3181a9c250 · Cited by 39
Practitioner-Level Determinants of Inappropriate Prostate-Specific Antigen Screening
Kerfoot, B. P., Holmberg, E. F., Lawler, E. V., Krupat, E., & Conlin, P. R. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.13.1367 · Cited by 34
Repeated Hemoglobin A1C Ordering in the VA Health System
Laxmisan, A., Vaughan‐Sarrazin, M., & Cram, P. M. (2011) · The American Journal of Medicine · doi:10.1016/j.amjmed.2010.10.019 · Cited by 34
Appropriateness of serum level determinations of antiepileptic drugs
Affolter, N. (2003) · Swiss Medical Weekly · doi:10.4414/smw.2003.10435 · Cited by 34
Analysis of blood tests in the emergency department of a tertiary care hospital
Rehmani, R. S., & Amanullah, S. (1999) · Postgraduate Medical Journal · doi:10.1136/pgmj.75.889.662 · Cited by 33
Appropriateness of digoxin level monitoring
Mordasini, M., & Schlienger, R. (2002) · Swiss Medical Weekly · doi:10.4414/smw.2002.10064 · Cited by 32
Towards evidence‐based use of serum tumour marker requests: an audit of use in a tertiary hospital
Loi, S., Haydon, A. M., Shapiro, J., Schwarz, M. A., & Schneider, H. G. (2004) · Internal Medicine Journal · doi:10.1111/j.1445-5994.2004.00671.x · Cited by 28
A quality management intervention to improve clinical laboratory use in acute myocardial infarction
Isouard, G. (1999) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1999.tb126856.x · Cited by 27
Jones, P., Elangbam, B., & Williams, N. R. (2009) · Emergency Medicine Journal · doi:10.1136/emj.2009.075838 · Cited by 26
Appropriateness of Lyme Disease Serologic Testing
Ramsey, A. (2004) · The Annals of Family Medicine · doi:10.1370/afm.117 · Cited by 25
Message from the President: Reducing Healthcare Costs through Appropriate Test Utilization
Alexander, C. B. (2012) · Critical Values · doi:10.1093/criticalvalues/5.2.6 · Cited by 25
Overuse of prothrombin and partial thromboplastin coagulation tests in medical inpatients
Pilsczek, F. H., Rifkin, W., & Walerstein, S. J. (2005) · Heart & Lung · doi:10.1016/j.hrtlng.2005.07.004 · Cited by 24
Potentially Inappropriate Repeat Laboratory Testing in Inpatients
Hawkins, R. C. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.064139 · Cited by 24
A quality management intervention to improve clinical laboratory use in acute myocardial infarction
Isouard, G. (1999) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1999.tb123619.x · Cited by 24
Utilisation of laboratory services by health workers in a district hospital in Malawi
Mepham, S., Squire, S. B., Chisuwo, L., Kandulu, J., & Bates, I. (2009) · Journal of Clinical Pathology · doi:10.1136/jcp.2009.069062 · Cited by 18
Inappropriate requests for serum anti-epileptic drug levels in hospital practice
Walters, R. J., Hutchings, A., Smith, D., & Smith, P. E. M. (2004) · QJM · doi:10.1093/qjmed/hch057 · Cited by 17
Appropriateness of antineutrophil cytoplasmic antibody testing in a tertiary hospital
Robinson, P. C., & Steele, R. H. (2009) · Journal of Clinical Pathology · doi:10.1136/jcp.2009.064485 · Cited by 17
Appropriateness of Prostate-Specific Antigen Testing
Poteat, H. T., Chen, P., Loughlin, K. R., Winkelman, J. W., Allada, R., Ma'Luf, N., Tanasijevic, M. J., & Bates, D. W. (2000) · American Journal of Clinical Pathology · doi:10.1309/e11x-491y-gujh-eggf · Cited by 17
Accountable Care Organizations: Accountable for What?
Mason, D. J. (2013) · JAMA Forum Archive · doi:10.1001/jamahealthforum.2013.0024 · Cited by 16
Tientadakul, P., Chinthammitr, Y., Sanpakit, K., Wongwanit, C., & Nilanont, Y. (2011) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2011.01332.x · Cited by 14
Hanna, D. B., Tsoi, B. W., & Begier, E. M. (2009) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e3181a4488f · Cited by 14
The incidence of duplicate genetic testing
Riegert‐Johnson, D. L., Macaya, D., Hefferon, T. W., & Boardman, L. A. (2008) · Genetics in Medicine · doi:10.1097/gim.0b013e31816166a7 · Cited by 14
Application of hepatitis serology testing algorithms to assess inappropriate laboratory utilization
Özbek, Ö. A., Öktem, M. A., Doğan, G., & Abacioglu, Y. H. (2004) · Journal of Evaluation in Clinical Practice · doi:10.1111/j.1365-2753.2003.00447.x · Cited by 14
Huissoon, A. P., & Carlton, S. (2002) · Journal of Clinical Pathology · doi:10.1136/jcp.55.1.78-a · Cited by 13
Castellví-Boada, J. M., & Castells, X. (1999) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1999.010 · Cited by 13
Compliance to Recommended Liver Function Monitoring in Patients on Statin Therapy
Leaver, H., Lim, T. K., Thomson, P., Leaver, J., Choy, A. M., & Lang, C. C. (2009) · Cardiovascular Therapeutics · doi:10.1111/j.1755-5922.2009.00082.x · Cited by 12
Orrico, K. B., Wu, M., & Wilson, A. R. (2011) · Journal of Managed Care Pharmacy · doi:10.18553/jmcp.2011.17.9.695 · Cited by 12
Lee, J., & Zierler, B. K. (2010) · Vascular and Endovascular Surgery · doi:10.1177/1538574410385873 · Cited by 11
An Audit of Preoperative Blood Tests
Putnis, S., Nanuck, J., & Heath, D. (2008) · Journal of Perioperative Practice · doi:10.1177/175045890801800201 · Cited by 10
Ward, S., Gilbert, S., Mulchandani, M. H., & Garrett, W. (2008) · The Surgeon · doi:10.1016/s1479-666x(08)80052-2 · Cited by 8
Mameli, A., Barcellona, D., Vannini, M. L., & Marongiu, F. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.111 · Cited by 7
GANIYU-DADA, Z., & Bowcock, S. J. (2011) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2011.01350.x · Cited by 5
Appropriate laboratory utilization in diagnosing pulmonary embolism
Fiappo, E., Quattrin, R., Calligaris, L., Cappelletti, P., & Brusaferro, S. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008095 · Cited by 5
Requisition Errors for Blood Glucose Tests: A Hospital-Based Study
Wiwanitkit, V., & Lekngarm, P. (2007) · Laboratory Medicine · doi:10.1309/hw46edw01g8b20xx · Cited by 4
The “Ulysses syndrome” in pathology: when more is less
Dorevitch, A. P. (1992) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1992.tb126447.x · Cited by 4
Inappropriate C-reactive protein testing in epistaxis patients
Biggs, T. C., & Nightingale, K. (2011) · Clinical Otolaryngology · doi:10.1111/j.1749-4486.2011.02357.x · Cited by 2
Research works printed but not linked: 2
- Smith M, Saunders R, Stuckhardt L, McGinnis JM, Committee on the Learning Health Care System in America, et al., editors (2012) Best Care at Lower Cost: The Path to Continuously Learning Health Care in America. Washington, D.C.: The National Academies Press. 24901184
- New England Healthcare Institute (2008) How Many More Studies Will It Take? A Collection of Evidence That Our Healthcare System Can Do Better. Cambridge, MA: New England Healthcare Institute.
Cited by
The Value of In Vitro Diagnostic Testing in Medical Practice: A Status Report
Rohr, U.-P., Binder, C., Dieterle, T., Giusti, F., Messina, C. G. M., Toerien, E., Moch, H., & Schäfer, H. H. (2016) · PLOS ONE · doi:10.1371/journal.pone.0149856 · Cited by 229
“Interestingly is also the fact that there were four times as many studies found on over- compared to underutilization during the assessed 15-year period and, despite in-depth literature research, only 42 studies finally matched the criteria for review, indicating a poor level of evidence on inappropriate use of IVD te…”
ResultThe carbon footprint of pathology testing
McAlister, S., Barratt, A. L., Bell, K. J., & McGain, F. (2020) · Medical Journal of Australia · doi:10.5694/mja2.50583 · Cited by 198
Overuse of diagnostic testing in healthcare: a systematic review
Müskens, J. L. J. M., Kool, R. B., van Dulmen, S. A., & Westert, G. P. (2022) · BMJ Quality & Safety · doi:10.1136/bmjqs-2020-012576 · Cited by 167
(2015) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2014.12.001 · Cited by 186
Evidence-Based Guidelines to Eliminate Repetitive Laboratory Testing
Eaton, K. P., Levy, K., Soong, C., Pahwa, A. K., Petrilli, C., Ziemba, J. B., Cho, H. J., Alban, R., Blanck, J. F., & Parsons, A. S. (2017) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.5152 · Cited by 178
Metadata
- Authors
- Zhi, M., Ding, E. L., Theisen-Toupal, J., Whelan, J., & Arnaout, R.
- Affiliations
- Harvard University (US)
- Brigham and Women's Hospital (US)
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Arnaout, Ramy
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2013-11-15
- Volume
- 8
- Issue
- 11
- Pages
- e78962
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3829815
- OpenAlex
- W1992231987
- Cited by
- 535
- References
- 75
- Citations by year
- 2026: 42 · 2025: 39 · 2024: 44 · 2023: 40 · 2022: 49 · 2021: 46 · 2020: 61 · 2019: 42 · 2018: 42 · 2017: 50 · 2016: 33 · 2015: 29 · 2014: 16 · 2013: 1
- FWCI
- 47.70
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Topics
- Health Sciences › Health Professions › General Health Professions › Healthcare cost, quality, practices
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Family Practice › Clinical Reasoning and Diagnostic Skills
- Keywords
- inappropriate laboratory testing, overuse of laboratory tests, retesting, test volume, appropriate use criteria, diagnostic testing utilization, quality of evidence, cost-effectiveness, health care costs, health care utilization, patient safety, patient satisfaction, patient-centered care, shared decision-making
- MeSH terms
- Diagnostic Errors, Humans, Clinical Laboratory Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.