Are Sample Sizes Clear and Justified in RCTs Published in Dental Journals?
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Sample size calculations are advocated by the CONSORT group to justify sample sizes in randomized controlled trials (RCTs). The aim of this study was primarily to evaluate the reporting of sample size calculations, to establish the accuracy of these calculations in dental RCTs and to explore potential predictors associated with adequate reporting. Electronic searching was undertaken in eight leading specific and general dental journals. Replication of sample size calculations was undertaken where possible. Assumed variances or odds for control and intervention groups were also compared against those observed. The relationship between parameters including journal type, number of authors, trial design, involvement of methodologist, single-/multi-center study and region and year of publication, and the accuracy of sample size reporting was assessed using univariable and multivariable logistic regression. Of 413 RCTs identified, sufficient information to allow replication of sample size calculations was provided in only 121 studies (29.3%). Recalculations demonstrated an overall median overestimation of sample size of 15.2% after provisions for losses to follow-up. There was evidence that journal, methodologist involvement (OR = 1.97, CI: 1.10, 3.53), multi-center settings (OR = 1.86, CI: 1.01, 3.43) and time since publication (OR = 1.24, CI: 1.12, 1.38) were significant predictors of adequate description of sample size assumptions. Among journals JCP had the highest odds of adequately reporting sufficient data to permit sample size recalculation, followed by AJODO and JDR, with 61% (OR = 0.39, CI: 0.19, 0.80) and 66% (OR = 0.34, CI: 0.15, 0.75) lower odds, respectively. Both assumed variances and odds were found to underestimate the observed values. Presentation of sample size calculations in the dental literature is suboptimal; incorrect assumptions may have a bearing on the power of RCTs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials
Schulz, K. F., Altman, D. G., Moher, D., & for the CONSORT Group (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000251 · Cited by 2,296
Freiman, J. A., Chalmers, T. C., Smith, H., & Kuebler, R. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197809282991304 · Cited by 1,628
On the use of a pilot sample for sample size determination
Browne, R. H. (1995) · Statistics in Medicine · doi:10.1002/sim.4780141709 · Cited by 1,007 · cited 2×
“The main reasons for inadequate assumptions of variances are that the assumptions are based on initial piloting, with the researchers following exactly the same variances for a much larger RCT, disregarding the fact that variance is not fixed [11].”
BackgroundMethodSample size calculations in randomised trials: mandatory and mystical
Schulz, K. F., & Grimes, D. A. (2005) · The Lancet · doi:10.1016/s0140-6736(05)61034-3 · Cited by 549
Reporting of sample size calculation in randomised controlled trials: review
Charles, P., Giraudeau, B., Dechartres, A., Baron, G., & Ravaud, P. (2009) · BMJ · doi:10.1136/bmj.b1732 · Cited by 274
Analysis of a trial randomised in clusters: Table 1
Kerry, S. M., & Bland, J. M. (1998) · BMJ · doi:10.1136/bmj.316.7124.54 · Cited by 153
Underpowering in randomized trials reporting a sample size calculation
Vickers, A. J. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00141-0 · Cited by 102 · cited 3×
“This difference may lead to insufficiently powered trials lacking the capacity to identify treatment differences risking incorrect inferences based on inconclusive outcomes [12].”
BackgroundInfluential
Cited by
CONSORT 2010 statement: extension checklist for reporting within person randomised trials
Pandis, N., Chung, B., Scherer, R. W., Elbourne, D., & Altman, D. G. (2017) · BMJ · doi:10.1136/bmj.j2835 · Cited by 257
Self-citationOutcome Discrepancies and Selective Reporting: Impacting the Leading Journals?
Fleming, P. S., Koletsi, D., Dwan, K., & Pandis, N. (2015) · PLOS ONE · doi:10.1371/journal.pone.0127495 · Cited by 80
“The veracity of the sample size calculations and the information contributing to the calculated values were not assessed in the present study; however, previous research has exposed problems in this respect [18, 19].”
ResultSelf-citationDental Research Waste in Design, Analysis, and Reporting: A Scoping Review
Pandis, N., Fleming, P. S., Katsaros, C., & Ioannidis, J. P. A. (2021) · Journal of Dental Research · doi:10.1177/0022034520962751 · Cited by 58
Self-citationData sharing and transparency indicators in published RCTs in Oral Health between 2017 and 2023
Mikelis, F., Karamalaki, D., Mikeli, A., Tzanetakis, G. N., & Koletsi, D. (2024) · Journal of Dentistry · doi:10.1016/j.jdent.2024.105263 · Cited by 8
Self-citation
Metadata
- Authors
- Koletsi, D., Fleming, P. S., Seehra, J., Bagos, P. G., & Pandis, N.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-01-21
- Volume
- 9
- Issue
- 1
- Pages
- e85949
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1979338890
- Cited by
- 52
- References
- 7
- FWCI
- 4.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Are Sample Sizes Clear and Justified in RCTs Published in Dental Journals? https://app.cochat.ai/papers/10.1371/journal.pone.0085949
- The paper
- Koletsi, D., Fleming, P. S., Seehra, J., Bagos, P. G., & Pandis, N. (2014). Are Sample Sizes Clear and Justified in RCTs Published in Dental Journals? PLoS ONE. https://doi.org/10.1371/journal.pone.0085949
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.