The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Open accessAbstract
Due to advances in the acquisition and analysis of medical imaging, it is currently possible to quantify the tumor phenotype. The emerging field of Radiomics addresses this issue by converting medical images into minable data by extracting a large number of quantitative imaging features. One of the main challenges of Radiomics is tumor segmentation. Where manual delineation is time consuming and prone to inter-observer variability, it has been shown that semi-automated approaches are fast and reduce inter-observer variability. In this study, a semiautomatic region growing volumetric segmentation algorithm, implemented in the free and publicly available 3D-Slicer platform, was investigated in terms of its robustness for quantitative imaging feature extraction. Fifty-six 3D-radiomic features, quantifying phenotypic differences based on tumor intensity, shape and texture, were extracted from the computed tomography images of twenty lung cancer patients. These radiomic features were derived from the 3D-tumor volumes defined by three independent observers twice using 3D-Slicer, and compared to manual slice-by-slice delineations of five independent physicians in terms of intra-class correlation coefficient (ICC) and feature range. Radiomic features extracted from 3D-Slicer segmentations had significantly higher reproducibility (ICC = 0.85±0.15, p = 0.0009) compared to the features extracted from the manual segmentations (ICC = 0.77±0.17). Furthermore, we found that features extracted from 3D-Slicer segmentations were more robust, as the range was significantly smaller across observers (p = 3.819e-07), and overlapping with the feature ranges extracted from manual contouring (boundary lower: p = 0.007, higher: p = 5.863e-06). Our results show that 3D-Slicer segmented tumor volumes provide a better alternative to the manual delineation for feature quantification, as they yield more reproducible imaging descriptors. Therefore, 3D-Slicer can be employed for quantitative image feature extraction and image data mining research in large patient cohorts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Self-citationDecoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132
Self-citationRadiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258 · cited 5×
“Radiomics addresses this issue, and refers to the high throughput extraction of a large number of quantitative and minable imaging features, assuming that these features convey prognostic and predictive information [3,4].”
BackgroundMethodInfluentialSelf-citationTexture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
CERR: A computational environment for radiotherapy research
Deasy, J. O., Blanco, A. I., & Clark, V. H. (2003) · Medical Physics · doi:10.1118/1.1568978 · Cited by 872
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Decoding global gene expression programs in liver cancer by noninvasive imaging
Segal, E., Sirlin, C. B., Ooi, C., Adler, A. S., Gollub, J., Chen, X., Chan, B. K., Matcuk, G. R., Barry, C. T., Chang, H. Y., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1306 · Cited by 629
Ganeshan, B., Panayiotou, E., Burnand, K., Dizdarevic, S., & Miles, K. (2012) · European Radiology · doi:10.1007/s00330-011-2319-8 · Cited by 505
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480
Non–Small Cell Lung Cancer: Histopathologic Correlates for Texture Parameters at CT
Ganeshan, B., Goh, V., Mandeville, H. C., Ng, Q. S., Hoskin, P. J., & Miles, K. A. (2013) · Radiology · doi:10.1148/radiol.12112428 · Cited by 447
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Self-citationAerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5644 · Cited by 352
Self-citationGalavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R. (2010) · Acta Oncologica · doi:10.3109/0284186x.2010.498437 · Cited by 344
Ganeshan, B., Abaleke, S., Young, R. C. D., Chatwin, C. R., & Miles, K. A. (2010) · Cancer Imaging · doi:10.1102/1470-7330.2010.0021 · Cited by 324
Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
van Baardwijk, A., Bosmans, G., Boersma, L., Buijsen, J., Wanders, S., Hochstenbag, M., van Suylen, R.-J., Dekker, A., Dehing-Oberije, C., Houben, R., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.067 · Cited by 295
Self-citationRadiogenomic Mapping of Edema/Cellular Invasion MRI-Phenotypes in Glioblastoma Multiforme
Zinn, P. O., Majadan, B., Sathyan, P., Singh, S. K., Majumder, S., Jolesz, F. A., & Colen, R. R. (2011) · PLoS ONE · doi:10.1371/journal.pone.0025451 · Cited by 265
GBM Volumetry using the 3D Slicer Medical Image Computing Platform
Egger, J., Kapur, T., Fedorov, A., Pieper, S., Miller, J. V., Veeraraghavan, H., Freisleben, B., Golby, A. J., Nimsky, C., & Kikinis, R. (2013) · Scientific Reports · doi:10.1038/srep01364 · Cited by 249
Self-citationVolumetric CT-based segmentation of NSCLC using 3D-Slicer
Velazquez, E. R., Parmar, C., Jermoumi, M., Mak, R. H., van Baardwijk, A., Fennessy, F. M., Lewis, J. H., De Ruysscher, D., Kikinis, R., Lambin, P., et al. (2013) · Scientific Reports · doi:10.1038/srep03529 · Cited by 240
Self-citationCombined PET/CT image characteristics for radiotherapy tumor response in lung cancer
Vaidya, M., Creach, K. M., Frye, J., Dehdashti, F., Bradley, J. D., & El Naqa, I. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.10.014 · Cited by 201
Buckler, A. J., Bresolin, L., Dunnick, N. R., Sullivan, D. C., & For the Group (2011) · Radiology · doi:10.1148/radiol.10100799 · Cited by 175
van Baardwijk, A., Wanders, S., Boersma, L., Borger, J., Öllers, M., Dingemans, A.-M. C., Bootsma, G., Geraedts, W., Pitz, C., Lunde, R., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.24.7221 · Cited by 168
Self-citationHeye, T. J., Merkle, E. M., Reiner, C. S., Davenport, M. S., Horvath, J. J., Feuerlein, S., Breault, S. R., Gall, P., Bashir, M. R., Dale, B. M., et al. (2012) · Radiology · doi:10.1148/radiol.12120255 · Cited by 159
Gu, Y., Kumar, V., Hall, L., Goldgof, D. B., Li, C.-Y., Korn, R., Bendtsen, C., Velazquez, E. R., Dekker, A. L. A. J., Aerts, H. J. W. L., et al. (2012) · Pattern Recognition · doi:10.1016/j.patcog.2012.10.005 · Cited by 141
Self-citationHunter, L. A., Krafft, S. P., Stingo, F. C., Choi, H., Martel, M. K., Kry, S. F., & Court, L. E. (2013) · Medical Physics · doi:10.1118/1.4829514 · Cited by 130
Rios Velazquez, E., Aerts, H. J. W. L., Gu, Y., Goldgof, D. B., De Ruysscher, D., Dekker, A., Korn, R., Gillies, R. J., & Lambin, P. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.09.023 · Cited by 120
Self-citationQuantitative Imaging Test Approval and Biomarker Qualification: Interrelated but Distinct Activities
Buckler, A. J., Bresolin, L. B., Dunnick, N. R., Sullivan, D. C., & For the Group (2011) · Radiology · doi:10.1148/radiol.10100800 · Cited by 94
Zinn, P. O., Sathyan, P., Mahajan, B., Bruyere, J. R., Hegi, M. E., Majumder, S., & Colen, R. R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0041522 · Cited by 90
Reproducibility of Dynamic Contrast-enhanced MR Imaging: Why We Should Care
Goh, V., Schaeffter, T., & Leach, M. O. (2013) · Radiology · doi:10.1148/radiol.12122447 · Cited by 38
Cited by
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Self-citationMachine Learning methods for Quantitative Radiomic Biomarkers
Parmar, C., Grossmann, P., Bussink, J., Lambin, P., & Aerts, H. J. W. L. (2015) · Scientific Reports · doi:10.1038/srep13087 · Cited by 1,019
Self-citationLiu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Metadata
- Authors
- Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., Lambin, P., & Aerts, H. J. W. L.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2014-07-15
- Volume
- 9
- Issue
- 7
- Pages
- e102107
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2052507258
- Cited by
- 611
- References
- 32
- FWCI
- 21.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.