Estimation of Physical Activity Energy Expenditure during Free-Living from Wrist Accelerometry in UK Adults
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Wrist-worn accelerometers are emerging as the most common instrument for measuring physical activity in large-scale epidemiological studies, though little is known about the relationship between wrist acceleration and physical activity energy expenditure (PAEE). METHODS: 1695 UK adults wore two devices simultaneously for six days; a combined sensor and a wrist accelerometer. The combined sensor measured heart rate and trunk acceleration, which was combined with a treadmill test to yield a signal of individually-calibrated PAEE. Multi-level regression models were used to characterise the relationship between the two time-series, and their estimations were evaluated in an independent holdout sample. Finally, the relationship between PAEE and BMI was described separately for each source of PAEE estimate (wrist acceleration models and combined-sensing). RESULTS: Wrist acceleration explained 44-47% between-individual variance in PAEE, with RMSE between 34-39 J•min-1•kg-1. Estimations agreed well with PAEE in cross-validation (mean bias [95% limits of agreement]: 0.07 [-70.6:70.7]) but overestimated in women by 3% and underestimated in men by 4%. Estimation error was inversely related to age (-2.3 J•min-1•kg-1 per 10y) and BMI (-0.3 J•min-1•kg-1 per kg/m2). Associations with BMI were similar for all PAEE estimates (approximately -0.08 kg/m2 per J•min-1•kg-1). CONCLUSIONS: A strong relationship exists between wrist acceleration and PAEE in free-living adults, such that irrespective of the objective method of PAEE assessment, a strong inverse association between PAEE and BMI was observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [51]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The total volume of PA was measured as the weekly average vector magnitude in milligravity (mg) units (field ID 90012), which is a wellvalidated surrogate for global PA.17,18”
From Joint association of physical activity and sleep duration with risk of all-cause and cause-specific mortality: A population-based cohort study using accelerometry (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredIn the citing paper
“This variable has been shown to account for 44–47% explained variance vs. combined sensing heart-rate + trunk-acceleration (a proxy for free-living physical activity energy expenditure) in 1695 UK adults51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [51]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Fit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926
Self-citationvan Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Self-citationReliability and validity of the combined heart rate and movement sensor Actiheart
Brage, S., Brage, N., Franks, P. W., Ekelund, U., & Wareham, N. J. (2005) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602118 · Cited by 667
Self-citationValidation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Kilpeläinen, T. O., Qi, L., Brage, S., Sharp, S. J., Sonestedt, E., Demerath, E., Ahmad, T., Mora, S., Kaakinen, M., Sandholt, C. H., et al. (2011) · PLoS Medicine · doi:10.1371/journal.pmed.1001116 · Cited by 559
Self-citationBrage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473
Self-citationValidity and repeatability of the EPIC-Norfolk Physical Activity Questionnaire
Wareham, N. J., Jakes, R. W., Rennie, K. L., Mitchell, J., Hennings, S., & Day, N. E. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.168 · Cited by 435
Self-citationBrage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Self-citation
Research works printed but not linked: 1
- Troiano R, McClain J. Objective measures of physical activity, sleep, and strength in US National Health and Nutrition Examination Survey (NHANES) 2011–2014. Proceedings of the 8th International Conference on Diet and Activity Methods. Rome, Italy; 2012. Available: http://www.fao.org/fileadmin/templates/food_composition/documents/ABSTRACT_BOOK.pdf
Cited by
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250
Self-citationGWAS identifies 14 loci for device-measured physical activity and sleep duration
Doherty, A., Smith-Byrne, K., Ferreira, T., Holmes, M. V., Holmes, C., Pulit, S. L., & Lindgren, C. M. (2018) · Nature Communications · doi:10.1038/s41467-018-07743-4 · Cited by 408
Wearable-device-measured physical activity and future health risk
Strain, T., Wijndaele, K., Dempsey, P. C., Sharp, S. J., Pearce, M., Jeon, J., Lindsay, T., Wareham, N., & Brage, S. (2020) · Nature Medicine · doi:10.1038/s41591-020-1012-3 · Cited by 355
Self-citationWilletts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
“For this study we did not use traditional cumbersome methods to collect sleep 34 and energy expenditure 35 groundtruth data, as we preferred to use proxy reference methods for free-living assessment at scale 35,36 .”
MethodPhysical activity volume, intensity, and incident cardiovascular disease
Dempsey, P. C., Rowlands, A. V., Strain, T., Zaccardi, F., Dawkins, N., Razieh, C., Davies, M. J., Khunti, K. K., Edwardson, C. L., Wijndaele, K., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac613 · Cited by 174
Self-citation
Metadata
- Authors
- White, T., Westgate, K., Wareham, N. J., & Brage, S.
- Affiliations
- University of Cambridge (GB)
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2016-12-09
- Volume
- 11
- Issue
- 12
- Pages
- e0167472
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5147924
- OpenAlex
- W2560176117
- Cited by
- 169
- References
- 19
- Citations by year
- 2026: 9 · 2025: 16 · 2024: 24 · 2023: 24 · 2022: 15 · 2021: 13 · 2020: 23 · 2019: 24 · 2018: 12 · 2017: 9
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Apollo (University of Cambridge) (submittedVersion, cc-by)
- Apollo (cc-by)
- Funders
- Medical Research Council (MC_UU_12015/3)
- MedImmune (N/A)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Obesity, Physical Activity, Diet
- Keywords
- physical activity energy expenditure, wrist-worn accelerometers, free-living physical activity, accelerometer calibration, heart rate monitoring, combined sensor, treadmill exercise testing, body mass index
- MeSH terms
- Adult, Algorithms, Diabetes Mellitus, Energy Metabolism, Exercise Test, Female, United Kingdom, Heart Rate, Humans, Male, Middle Aged, Monitoring, Physiologic, Obesity, Prospective Studies, Wrist, Reproducibility of Results, Exercise, Body Mass Index, Linear Models, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of Physical Activity Energy Expenditure during Free-Living from Wrist Accelerometry in UK Adults. https://app.cochat.ai/papers/10.1371/journal.pone.0167472
- The paper
- White, T., Westgate, K., Wareham, N. J., & Brage, S. (2016). Estimation of Physical Activity Energy Expenditure during Free-Living from Wrist Accelerometry in UK Adults. PLOS ONE. https://doi.org/10.1371/journal.pone.0167472
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.