When a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Physical activity is an essential aspect of a healthy lifestyle for both physical and mental health states. As step count is one of the most utilized measures for quantifying physical activity it is important that activity-monitoring devices be both sensitive and specific in recording actual steps taken and disregard non-stepping body movements. The objective of this study was to assess the specificity of five activity monitors during a variety of prescribed non-stepping activities. METHODS: Participants wore five activity monitors simultaneously for a variety of prescribed activities including deskwork, taking an elevator, taking a bus journey, automobile driving, washing and drying dishes; functional reaching task; indoor cycling; outdoor cycling; and indoor rowing. Each task was carried out for either a specific duration of time or over a specific distance. Activity monitors tested were the ActivPAL micro™, NL-2000™ pedometer, Withings Smart Activity Monitor Tracker (Pulse O2)™, Fitbit One™ and Jawbone UP™. Participants were video-recorded while carrying out the prescribed activities and the false positive step count registered on each activity monitor was obtained and compared to the video. RESULTS: All activity monitors registered a significant number of false positive steps per minute during one or more of the prescribed activities. The Withings™ activity performed best, registering a significant number of false positive steps per minute during the outdoor cycling activity only (P = 0.025). The Jawbone™ registered a significant number of false positive steps during the functional reaching task and while washing and drying dishes, which involved arm and hand movement (P < 0.01 for both). The ActivPAL™ registered a significant number of false positive steps during the cycling exercises (P < 0.001 for both). CONCLUSION: As a number of false positive steps were registered on the activity monitors during the non-stepping activities, the authors conclude that non-stepping physical activities can result in the false detection of steps. This can negatively affect the quantification of physical activity with regard to step count as an output. The Withings™ activity monitor performed best with regard to specificity during the activities of daily living tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Penedo, F. J., & Dahn, J. R. (2005) · Current Opinion in Psychiatry · doi:10.1097/00001504-200503000-00013 · Cited by 2,851
How Many Steps/Day Are Enough?: Preliminary Pedometer Indices for Public Health
Tudor-Locke, C., & Bassett, D. R. (2004) · Sports Medicine · doi:10.2165/00007256-200434010-00001 · Cited by 2,054
Effect of Pedometer-Based Physical Activity Interventions: A Meta-Analysis
Kang, M., Marshall, S. J., Barreira, T. V., & Lee, J.-O. (2009) · Research Quarterly for Exercise & Sport · doi:10.5641/027013609x13088500160000 · Cited by 148
Accuracy of Wristband Activity Monitors during Ambulation and Activities
CHEN, M.-D., KUO, C.-C., PELLEGRINI, C. A., & HSU, M.-J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000984 · Cited by 90
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
“Misfit devices were used in 12 studies [9,36,42,43,46,61-63,85,95-97]; Polar devices were used in 6 studies [36,43,46,62,98,99]; Withings [63,85,89,100,101], Mio [29,30,54,102,103], and Samsung [29,30,58,62,96] devices were used in 5 studies; PulseOn devices were used in 4 studies [29,104-106]; TomTom devices were use…”
MethodInfluentialTedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O'Flynn, B. (2019) · JMIR mHealth and uHealth · doi:10.2196/13084 · Cited by 139
Maylor, B. D., Edwardson, C. L., Dempsey, P. C., Patterson, M. R., Plekhanova, T., Yates, T., & Rowlands, A. V. (2022) · Sensors · doi:10.3390/s22249984 · Cited by 30
Metadata
- Authors
- O’Connell, S., ÓLaighin, G., & Quinlan, L. R.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-01-13
- Volume
- 12
- Issue
- 1
- Pages
- e0169616
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2576624752
- Cited by
- 40
- References
- 4
- FWCI
- 3.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: When a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors. https://app.cochat.ai/papers/10.1371/journal.pone.0169616
- The paper
- O’Connell, S., ÓLaighin, G., & Quinlan, L. R. (2017). When a Step Is Not a Step! Specificity Analysis of Five Physical Activity Monitors. PLOS ONE. https://doi.org/10.1371/journal.pone.0169616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.