Extracting time-frequency feature of single-channel vastus medialis EMG signals for knee exercise pattern recognition
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The EMG signal indicates the electrophysiological response to daily living of activities, particularly to lower-limb knee exercises. Literature reports have shown numerous benefits of the Wavelet analysis in EMG feature extraction for pattern recognition. However, its application to typical knee exercises when using only a single EMG channel is limited. In this study, three types of knee exercises, i.e., flexion of the leg up (standing), hip extension from a sitting position (sitting) and gait (walking) are investigated from 14 healthy untrained subjects, while EMG signals from the muscle group of vastus medialis and the goniometer on the knee joint of the detected leg are synchronously monitored and recorded. Four types of lower-limb motions including standing, sitting, stance phase of walking, and swing phase of walking, are segmented. The Wavelet Transform (WT) based Singular Value Decomposition (SVD) approach is proposed for the classification of four lower-limb motions using a single-channel EMG signal from the muscle group of vastus medialis. Based on lower-limb motions from all subjects, the combination of five-level wavelet decomposition and SVD is used to comprise the feature vector. The Support Vector Machine (SVM) is then configured to build a multiple-subject classifier for which the subject independent accuracy will be given across all subjects for the classification of four types of lower-limb motions. In order to effectively indicate the classification performance, EMG features from time-domain (e.g., Mean Absolute Value (MAV), Root-Mean-Square (RMS), integrated EMG (iEMG), Zero Crossing (ZC)) and frequency-domain (e.g., Mean Frequency (MNF) and Median Frequency (MDF)) are also used to classify lower-limb motions. The five-fold cross validation is performed and it repeats fifty times in order to acquire the robust subject independent accuracy. Results show that the proposed WT-based SVD approach has the classification accuracy of 91.85%±0.88% which outperforms other feature models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle fatigue: what, why and how it influences muscle function
Enoka, R. M., & Duchateau, J. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.139477 · Cited by 1,672
Biomechanical design of the Berkeley lower extremity exoskeleton (BLEEX)
Zoss, A. B., Kazerooni, H., & Chu, A. (2006) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2006.871087 · Cited by 1,170
Zeilig, G., Weingarden, H., Zwecker, M., Dudkiewicz, I., Bloch, A., & Esquenazi, A. (2012) · The Journal of Spinal Cord Medicine · doi:10.1179/2045772312y.0000000003 · Cited by 537
Cited by
ViT-LLMR: Vision Transformer-based lower limb motion recognition from fusion signals of MMG and IMU
Zhang, H., Yang, K., Cao, G., & Xia, C. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104508 · Cited by 28
A Novel Wearable Foot and Ankle Monitoring System for the Assessment of Gait Biomechanics
Faragó, P., Grama, L., Farago, M.-A., & Hintea, S. (2020) · Applied Sciences · doi:10.3390/app11010268 · Cited by 22
Metadata
- Authors
- Zhang, Y., Li, P., Zhu, X., Su, S. W., Guo, Q., Xu, P., & Yao, D.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-07-10
- Volume
- 12
- Issue
- 7
- Pages
- e0180526
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2735021484
- Cited by
- 45
- References
- 3
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extracting time-frequency feature of single-channel vastus medialis EMG signals for knee exercise pattern recognition. https://app.cochat.ai/papers/10.1371/journal.pone.0180526
- The paper
- Zhang, Y., Li, P., Zhu, X., Su, S. W., Guo, Q., Xu, P., & Yao, D. (2017). Extracting time-frequency feature of single-channel vastus medialis EMG signals for knee exercise pattern recognition. PLOS ONE. https://doi.org/10.1371/journal.pone.0180526
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.