CoChat

Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction—Measurement by ELISA

Open access
Yokoyama, Shozo, Takeuchi, Akihiro, Yamaguchi, Shunsuke, Mitani, Yasuyuki, Watanabe, Takashi, Matsuda, Kenji, Hotta, Tsukasa, Shively, John E., Yamaue, Hiroki · 2017 · PLOS ONE
Cited by 107

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Serum exosomal proteins have great potential as indicators of disease status in cancer, inflammatory or metabolic diseases. The association of a fraction of various serum proteins such as carcinoembryonic antigen (CEA) with circulating exosomes has been debated. The establishment of a method to measure the exosomal fraction of such proteins might help resolve this controversy. The use of enzyme-linked immunosorbent assays (ELISAs) to measure serum exosomal molecules, for example CEA, is rare in research laboratories and totally absent in clinical biology. In this study, we optimized a method for assessment of serum exosomal molecules combining a treatment by volume-excluding polymers to isolate the exosomes, their subsequent solubilization in an assay buffer and ELISA. METHODS: One hundred sixteen consecutive patients with colorectal cancer were enrolled for this study between June 2015 and June 2016 at Wakayama Medical University Hospital (WMUH). Whole blood samples were collected from patients during surgery. Exosomes were isolated using the ExoQuick reagent, solubilized in an assay buffer and subjected to CEA detection by ELISA. The procedure of serum exosome isolation and the formulation of the assay buffer used for the ELISA were optimized in order to improve the sensitivity and specificity of the assay. RESULTS: A five-fold increase in the concentration of the exosomes in the assay buffer (using initial serum volume as a reference) and the addition of bovine serum albumin (BSA) resulted in more accurate measurements of the serum exosomal CEA. The thawing temperature of frozen serum samples before exosome extraction was also optimized. A validation study that included one hundred sixteen patients with colorectal cancer demonstrated that serum exosomal CEA from samples thawed at 25°C exhibited a better AUC value, sensitivity, and specificity as well as a more correct classification than serum CEA. CONCLUSIONS: We optimized an easy and rapid detection method for assessment of serum exosomal CEA. The thawing temperature of frozen serum prior to exosome extraction, the formulation of the assay buffer used for exosome solubilization and the concentration of the exosomes in this buffer were fine-tuned to enable the appropriate and accurate measurement of serum exosomal CEA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0183337

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 107

Metadata

Authors
Yokoyama, S., Takeuchi, A., Yamaguchi, S., Mitani, Y., Watanabe, T., Matsuda, K., Hotta, T., Shively, J. E., & Yamaue, H.
Venue
PLOS ONE
Published
2017-08-17
Volume
12
Issue
8
Pages
e0183337
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2748440594
Cited by
107
References
5
FWCI
2.33
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction—Measurement by ELISA. https://app.cochat.ai/papers/10.1371/journal.pone.0183337
The paper
Yokoyama, S., Takeuchi, A., Yamaguchi, S., Mitani, Y., Watanabe, T., Matsuda, K., Hotta, T., Shively, J. E., & Yamaue, H. (2017). Clinical implications of carcinoembryonic antigen distribution in serum exosomal fraction—Measurement by ELISA. PLOS ONE. https://doi.org/10.1371/journal.pone.0183337

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.