Telesonography in emergency medicine: A systematic review
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Ultrasound is an efficacious, versatile and affordable imaging technique in emergencies, but has limited utility without expert interpretation. Telesonography, in which experts may remotely support the use of ultrasound through a telecommunications link, may broaden access to ultrasound and improve patient outcomes, particularly in remote settings. This review assesses the literature regarding telesonography in emergency medicine, focussing on evidence of feasibility, diagnostic accuracy and clinical utility. A systematic search was performed for articles published from 1946 to February 2017 using the Cochrane, Medline, EMBASE, and CINAHL databases. Further searches utilising Scopus, Google Scholar, and citation lists were conducted. 4388 titles were identified and screened against inclusion criteria which resulted in the inclusion of 28 papers. These included feasibility, diagnostic accuracy and clinical pilot studies. Study design, methodology and quality were heterogeneous. There was good evidence of feasibility from multiple studies. Where sufficient bandwidth and high quality components were used, diagnostic accuracy was slightly reduced by image transmission. There was evidence of clinical utility in remote hospitals and low-resource settings, although reliability was infrequently reported. Further exploratory research is required to determine minimum requirements for image quality, bandwidth, frame rate and to assess diagnostic accuracy. Clinical trials in remote settings are justifiable. Telecommunication options will depend on local requirements; no one system conveys universal advantages. The methodological quality of research in this field must improve: studies should be designed to minimise bias, and must include details of their methods to allow replication. Analysis of cost effectiveness and sustainability should be provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · BMJ · doi:10.1136/bmj.h5527 · Cited by 3,660 · cited 2×
“Diagnostic accuracy studies could refer to guidelines such as Standards for Reporting of Diagnostic Accuracy (STARD) or QUADAS-2 [14, 85].”
MethodFeigin, V. L., Norrving, B., & Mensah, G. A. (2017) · Circulation Research · doi:10.1161/circresaha.116.308413 · Cited by 2,184
What is a pilot or feasibility study? A review of current practice and editorial policy
Arain, M., Campbell, M. J., Cooper, C. L., & Lancaster, G. A. (2010) · BMC Medical Research Methodology · doi:10.1186/1471-2288-10-67 · Cited by 1,483 · cited 1×
“Particular care should be taken to ensure study validity when designing feasibility and pilot studies [83].”
BackgroundEvaluation Framework for Telemedicine Using the Logical Framework Approach and a Fishbone Diagram
Chang, H. (2015) · Healthcare Informatics Research · doi:10.4258/hir.2015.21.4.230 · Cited by 74 · cited 1×
“When discussing studies conducted in the clinical environment authors should consider the applicability of their system from multiple perspectives (including the patient, healthcare provider and organisation); frameworks are available to aid this process [81, 82, 86, 87].”
BackgroundTelemedicine in South Africa: success or failure?
Gulube, S. M., & Wynchank, S. (2001) · Journal of Telemedicine and Telecare · doi:10.1258/1357633011937100 · Cited by 62
Tele-intensivists can instruct non-physicians to acquire high-quality ultrasound images
Levine, A. R., McCurdy, M. T., Zubrow, M. T., Papali, A., Mallemat, H. A., & Verceles, A. C. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.05.030 · Cited by 55 · cited 10×
“The time taken for scanning ranged from 4 minutes for a scan which was tele-mentored [29] to 24 minutes for a scan using a robotic device [21]; most examinations took less than 10 minutes [20, 23, 29, 30, 42].”
BackgroundMethodInfluentialA low-cost tele-imaging platform for developing countries
Adambounou, K., Adjenou, V., Salam, A. P., Farin, F., N’Dakena, K. G., Gbeassor, M., & Arbeille, P. (2014) · Frontiers in Public Health · doi:10.3389/fpubh.2014.00135 · Cited by 41 · cited 9×
“No synchronous system reported a transmission delay of more than 2s [15, 22, 23, 42], and such a delay was perceived as near to real time by users [15, 22].”
BackgroundMethodInfluentialHasselberg, M., Beer, N., Blom, L., Wallis, L. A., & Laflamme, L. (2014) · PLoS ONE · doi:10.1371/journal.pone.0098539 · Cited by 37
Ultrasound images transmitted via FaceTime are non-inferior to images on the ultrasound machine
Levine, A. R., Buchner, J. A., Verceles, A. C., Zubrow, M. T., Mallemat, H. A., Papali, A., & McCurdy, M. T. (2016) · Journal of Critical Care · doi:10.1016/j.jcrc.2016.02.019 · Cited by 34 · cited 10×
“, USA) was comparable to the teleICU system when using a good internet connection [31].”
BackgroundInfluential
Cited by
AI Estimation of Gestational Age from Blind Ultrasound Sweeps in Low-Resource Settings
Pokaprakarn, T., Prieto, J. C., Price, J. T., Kasaro, M. P., Sindano, N., Shah, H. R., Peterson, M., Akapelwa, M. M., Kapilya, F. M., Sebastião, Y. V., et al. (2022) · NEJM Evidence · doi:10.1056/evidoa2100058 · Cited by 80
Telemedicine in the emergency department: an overview of systematic reviews
Sharifi Kia, A., Rafizadeh, M., & Shahmoradi, L. (2023) · Journal of Public Health · doi:10.1007/s10389-021-01684-x · Cited by 60
Review of Systematic Reviews in the Field of Telemedicine
Goharinejad, S., Hajesmaeel-Gohari, S., Jannati, N., Goharinejad, S., & Bahaadinbeigy, K. (2021) · Medical Journal of The Islamic Republic of Iran · doi:10.47176/mjiri.35.184 · Cited by 18
Metadata
- Authors
- Marsh-Feiley, G., Eadie, L., & Wilson, P.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-05-03
- Volume
- 13
- Issue
- 5
- Pages
- e0194840
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2800804068
- Cited by
- 54
- References
- 10
- FWCI
- 0.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Telesonography in emergency medicine: A systematic review. https://app.cochat.ai/papers/10.1371/journal.pone.0194840
- The paper
- Marsh-Feiley, G., Eadie, L., & Wilson, P. (2018). Telesonography in emergency medicine: A systematic review. PLOS ONE. https://doi.org/10.1371/journal.pone.0194840
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.