Best practices for standardized performance testing of infrared thermographs intended for fever screening
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Infrared (IR) modalities represent the only currently viable mass fever screening approaches for outbreaks of infectious disease pandemics such as Ebola virus disease and severe acute respiratory syndrome. Non-contact IR thermometers (NCITs) and IR thermographs (IRTs) have been used for fever screening in public areas such as airports. While NCITs remain a more popular choice than IRTs, there has been increasing evidences in the literature that IRTs can provide great accuracy in estimating body temperature if qualified systems are used and appropriate procedures are consistently applied. In this study, we addressed the issue of IRT qualification by implementing and evaluating a battery of test methods for objective, quantitative assessment of IRT performance based on a recent international standard (IEC 80601-2-59). We tested two commercial IRTs to evaluate their stability and drift, image uniformity, minimum resolvable temperature difference, and radiometric temperature laboratory accuracy. Based on these tests, we illustrated how experimental and data processing procedures could affect results, and suggested methods for clarifying and optimizing test methods. Overall, the insights into thermograph standardization and acquisition methods provided by this study may improve the utility of IR thermography and aid in comparing IRT performance, thus improving the potential for producing high quality disease pandemic countermeasures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Guidelines for evaluating and expressing the uncertainty of NIST measurement results
Taylor, B. N. (1994) · National Institute of Standards and Technology, NIST Technical Note 1297 · doi:10.6028/nist.tn.1297 · Cited by 2,833
Public health interventions and SARS spread, 2003
Bell, D. M., & World Health Organization Working Group on Prevention of International and Community Transmission of SARS (2004) · Emerging Infectious Diseases · doi:10.3201/eid1011.040729 · Cited by 272
Is thermal scanner losing its bite in mass screening of fever due to SARS?
Ng, E. Y. ‐. (2005) · Medical Physics · doi:10.1118/1.1819532 · Cited by 86
Kosus, N., Kosus, A., Duran, M., Simavli, S., & Turhan, N. (2010) · Journal of the Turkish-German Gynecological Association · doi:10.5152/jtgga.2010.24 · Cited by 49
Cited by
Khaksari, K., Nguyen, T., Hill, B. Y., Perrault, J., Gorti, V., Blick, E., Gonzalez Cano, T., Shadgan, B., Quang, T., Malpani, R., et al. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.s1.010901 · Cited by 55
“The study found that the temperature, humidity, and type of data processing methods significantly affected IRT results.(26) Ring et al.”
BackgroundMethodWang, Q., Zhou, Y., Ghassemi, P., McBride, D., Casamento, J. P., & Pfefer, T. J. (2021) · Sensors · doi:10.3390/s22010215 · Cited by 48
“The laboratory accuracy of both IRT systems satisfied the IEC 80601-2-59:2017 standard requirements [30] in terms of stability, drift, minimum resolvable temperature difference, and radiometric temperature laboratory accuracy, as shown in our previous study [32].”
BackgroundMethodInfluentialSelf-citationNon-contact infrared assessment of human body temperature: The journal Temperature toolbox
Foster, J., Lloyd, A. B., & Havenith, G. (2021) · Temperature · doi:10.1080/23328940.2021.1899546 · Cited by 46
“The ETRS should not be larger than 10% of the face to not adversely affect the infrared camera, though it has been suggested that sizes up to 20% may still work ok [24].”
An Infrared Thermography Model Enabling Remote Body Temperature Screening Up to 10 Meters
Chin, J. W., Long Wong, K., Chan, T. T., Suhartono, K., & So, R. H. Y. (2021) · 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw53098.2021.00429 · Cited by 16
“Ghassemi and colleagues [9] suggested methods to optimize performance and testing for thermographic fever screening.”
Method
Metadata
- Authors
- Ghassemi, P., Pfefer, T. J., Casamento, J. P., Simpson, R., & Wang, Q.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-09-19
- Volume
- 13
- Issue
- 9
- Pages
- e0203302
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2890786165
- Cited by
- 82
- References
- 6
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Best practices for standardized performance testing of infrared thermographs intended for fever screening. https://app.cochat.ai/papers/10.1371/journal.pone.0203302
- The paper
- Ghassemi, P., Pfefer, T. J., Casamento, J. P., Simpson, R., & Wang, Q. (2018). Best practices for standardized performance testing of infrared thermographs intended for fever screening. PLOS ONE. https://doi.org/10.1371/journal.pone.0203302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.