The validity of two commercially-available sleep trackers and actigraphy for assessment of sleep parameters in obstructive sleep apnea patients
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The use of activity and sleep trackers that operate through dedicated smartphone applications has become popular in the general population. However, the validity of the data they provide has been disappointing and only Total Sleep Time (TST) is reliably recorded in healthy individuals for any of the devices tested. The purpose of this study was to evaluate the ability of two sleep trackers (Withings pulse 02 (W) and Jawbone Up (U)) to measure sleep parameters in patients suffering from obstructive sleep apnea (OSA). METHODS: All patients evaluated for OSA in our sleep laboratory underwent overnight polysomnography (PSG). PSG was conducted simultaneously with three other devices: two consumer-level sleep monitors (U and W) and one actigraph (Bodymedia SenseWear Pro Armband (SWA)). RESULTS: Of 36 patients evaluated, 22 (17 men) were diagnosed with OSA (mean apnea-hypopnea index of 37+ 23/h). Single comparisons of sleep trackers (U and W) and actigraph (SWA) were performed. Compared to PSG, SWA correctly assessed TST and Wake After Sleep Onset (WASO), and U and W correctly assessed Time In Bed (TIB) and light sleep. Intraclass correlations (ICC) revealed poor validity for all parameters and devices, except for WASO assessed by SWA. CONCLUSIONS: This is the first study assessing the validity of sleep trackers in OSA patients. In this series, we have confirmed the limited performance of wearable sleep monitors that has been previously observed in healthy subjects. In OSA patients, wearable app-based health technologies provide a good estimation of TIB and light sleep but with very poor ICC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berry, R. B., Budhiraja, R., Gottlieb, D. J., Gozal, D., Iber, C., Kapur, V. K., Marcus, C. L., Mehra, R., Parthasarathy, S., Quan, S. F., et al. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2172 · Cited by 5,302
STOP Questionnaire: A Tool to Screen Patients for Obstructive Sleep Apnea
Chung, F., Yegneswaran, B., Liao, P., Chung, S. A., Vairavanathan, S., Islam, S., Khajehdehi, A., & Shapiro, C. M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816d83e4 · Cited by 2,355 · cited 1×
“All patients were classified as “at risk” for OSA according to the STOP-BANG questionnaire [12]: the mean score was 4.”
MethodKushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · cited 1×
“These applications are focused on activity and sleep and allow individuals to monitor their general health [2].”
BackgroundMantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Kang, S.-G., Kang, J. M., Ko, K.-P., Park, S.-C., Mariani, S., & Weng, J. (2017) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2017.03.009 · Cited by 146
Evaluation of a consumer fitness-tracking device to assess sleep in adults
de Zambotti, M., Claudatos, S., Inkelis, S., Colrain, I. M., & Baker, F. C. (2015) · Chronobiology International · doi:10.3109/07420528.2015.1054395 · Cited by 127
Sleep Tracking, Wearable Technology, and Opportunities for Research and Clinical Care
Shelgikar, A. V., Anderson, P. F., & Stephens, M. R. (2016) · Chest · doi:10.1016/j.chest.2016.04.016 · Cited by 104 · cited 1×
“One interesting avenue for future development of consumer sleep trackers could be based on electroencephalographic readings [31], leading to the collection of numerous physiologic data to assess sleep structure, and, thus, potentially to Fig 1.”
BackgroundGruwez, A., Libert, W., Ameye, L., & Bruyneel, M. (2017) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2017.03.008 · Cited by 45
Self-citation
Cited by
Bi-directional relationships between co-morbid insomnia and sleep apnea (COMISA)
Sweetman, A., Lack, L., McEvoy, R. D., Smith, S., Eckert, D. J., Osman, A., Carberry, J. C., Wallace, D., Nguyen, P. D., & Catcheside, P. (2021) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2021.101519 · Cited by 203
Bauer, M., Glenn, T., Geddes, J., Gitlin, M., Grof, P., Kessing, L. V., Monteith, S., Faurholt-Jepsen, M., Severus, E., & Whybrow, P. C. (2020) · International Journal of Bipolar Disorders · doi:10.1186/s40345-019-0164-x · Cited by 163
Moreno-Pino, F., Porras-Segovia, A., López-Esteban, P., Artés, A., & Baca-García, E. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.8032 · Cited by 112
O’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
“The ability of two wrist worn sleep trackers; Withings pulse 02 and Jawbone Up and one actigraph (Bodymedia SenseWear Pro Armband) to measure sleep architecture and sleep quantity in patients diagnosed with OSA assessed during one polysomnographic recording night in a general sleep laboratory was evaluated in 32 patie…”
Method
Metadata
- Authors
- Gruwez, A., Bruyneel, A.-V., & Bruyneel, M.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2019-01-09
- Volume
- 14
- Issue
- 1
- Pages
- e0210569
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2908836076
- Cited by
- 64
- References
- 10
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The validity of two commercially-available sleep trackers and actigraphy for assessment of sleep parameters in obstructive sleep apnea patients. https://app.cochat.ai/papers/10.1371/journal.pone.0210569
- The paper
- Gruwez, A., Bruyneel, A.-V., & Bruyneel, M. (2019). The validity of two commercially-available sleep trackers and actigraphy for assessment of sleep parameters in obstructive sleep apnea patients. PLOS ONE. https://doi.org/10.1371/journal.pone.0210569
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.