Toward a compact hybrid brain-computer interface (BCI): Performance evaluation of multi-class hybrid EEG-fNIRS BCIs with limited number of channels
Open accessThe DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
It has been demonstrated that the performance of typical unimodal brain-computer interfaces (BCIs) can be noticeably improved by combining two different BCI modalities. This so-called "hybrid BCI" technology has been studied for decades; however, hybrid BCIs that particularly combine electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) (hereafter referred to as hBCIs) have not been widely used in practical settings. One of the main reasons why hBCI systems are so unpopular is that their hardware is generally too bulky and complex. Therefore, to make hBCIs more appealing, it is necessary to implement a lightweight and compact hBCI system with minimal performance degradation. In this study, we investigated the feasibility of implementing a compact hBCI system with significantly less EEG channels and fNIRS source-detector (SD) pairs, but that can achieve a classification accuracy high enough to be used in practical BCI applications. EEG and fNIRS data were acquired while participants performed three different mental tasks consisting of mental arithmetic, right-hand motor imagery, and an idle state. Our analysis results showed that the three mental states could be classified with a fairly high classification accuracy of 77.6 ± 12.1% using an hBCI system with only two EEG channels and two fNIRS SD pairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
![Fig 1 Arrangement of EEG channels (blue) and fNIRS optodes (red: Sources, green: Detectors) on the frontal (left) and motor (right) areas. Channels were numbered in the same manner as in a previous study [20].](https://figures.cochat.ai/paper-figures/81515620525741e0996158567bd74420/toward-a-compact-hybrid-brain-computer-interface-bci-performance-evaluation-of-figure-1.jpg)




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Separately, the feasibility of non-invasive methods for communication brain computer interfaces is being actively investigated77–80, with the goal of improving signal-to-noise and spatial resolution.”
From The speech neuroprosthesis (2024) · cites this paper as [78]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“com/bbci/bbci_public) were employed [22, 23].”
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A well-conditioned estimator for large-dimensional covariance matrices
Ledoit, O., & Wolf, M. (2004) · Journal of Multivariate Analysis · doi:10.1016/s0047-259x(03)00096-4 · Cited by 3,046 · cited 1×
“The fNIRS data were segmented into epochs from −1 to 15 s considering that the hemodynamic delay is in the order of several seconds [27].”
MethodBrain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Mu rhythm (de)synchronization and EEG single-trial classification of different motor imagery tasks
Pfurtscheller, G., Brunner, C., Schlögl, A., & Lopes da Silva, F. H. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.12.003 · Cited by 1,587
Schäfer, J., & Strimmer, K. (2005) · Statistical Applications in Genetics and Molecular Biology · doi:10.2202/1544-6115.1175 · Cited by 1,561
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Single-trial analysis and classification of ERP components — A tutorial
Blankertz, B., Lemm, S., Treder, M., Haufe, S., & Müller, K.-R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.06.048 · Cited by 1,138
Research works printed but not linked: 1
- M Tomczak, 2014, The need to report effect size estimates revisited. An overview of some recommended measures of effect size, Trends Sport Sci, 21
Cited by
Concurrent fNIRS and EEG for Brain Function Investigation: A Systematic, Methodology-Focused Review
Li, R., Yang, D., Fang, F., Hong, K.-S., Reiss, A. L., & Zhang, Y. (2022) · Sensors · doi:10.3390/s22155865 · Cited by 236
A systematic review on hybrid EEG/fNIRS in brain-computer interface
Liu, Z., Shore, J., Wang, M., Yuan, F., Buss, A. T., & Zhao, X. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102595 · Cited by 167
Silva, A. B., Littlejohn, K. T., Liu, J. R., Moses, D. A., & Chang, E. F. (2024) · Nature Reviews Neuroscience · doi:10.1038/s41583-024-00819-9 · Cited by 103
Analysis of Human Gait Using Hybrid EEG-fNIRS-Based BCI System: A Review
Khan, H., Naseer, N., Yazidi, A., Eide, P. K., Hassan, H. W., & Mirtaheri, P. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.613254 · Cited by 106
Yang, D., Shin, Y., & Hong, K. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.629323 · Cited by 94
“In addition, hybrid neuroimaging modalities have been suggested to evaluate the neuromodulation effect to seek reliable results (Kwon et al., 2020; Lee S. et al., 2020).”
Background
Metadata
- Authors
- Kwon, J., Shin, J., & Im, C.-H.
- Affiliations
- Hanyang University (KR)
- Wonkwang University (KR)
- Corresponding author
- Im, Chang-Hwan
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-03-18
- Volume
- 15
- Issue
- 3
- Pages
- e0230491
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC7080269
- OpenAlex
- W3010955800
- Cited by
- 53
- References
- 41
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 11 · 2023: 7 · 2022: 5 · 2021: 15 · 2020: 4
- FWCI
- 4.17
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Research Foundation
- National Research Foundation of Korea (2017-0-00432, 2015M3C7A1031969, NRF‐2015M3C7A1031969, 2019M3C7A1031278, NRF-2019M3C7A1031278)
- Ministry of Science and ICT, South Korea (NRF-2019M3C7A1031278, 2017-0-00432)
- Institute for Information and Communications Technology Promotion (2017-0-00432)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Keywords
- hybrid brain-computer interface, functional near-infrared spectroscopy, EEG, multi-class classification, mental arithmetic, motor imagery, mental state classification
- MeSH terms
- Adult, Electroencephalography, Female, Humans, Male, Models, Theoretical, Motor Cortex, Psychomotor Performance, Spectroscopy, Near-Infrared, Young Adult, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward a compact hybrid brain-computer interface (BCI): Performance evaluation of multi-class hybrid EEG-fNIRS BCIs with limited number of channels. https://app.cochat.ai/papers/10.1371/journal.pone.0230491
- The paper
- Kwon, J., Shin, J., & Im, C.-H. (2020). Toward a compact hybrid brain-computer interface (BCI): Performance evaluation of multi-class hybrid EEG-fNIRS BCIs with limited number of channels. PLOS ONE. https://doi.org/10.1371/journal.pone.0230491
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.