CoChat

Comparison of central laboratory HbA1c measurements obtained from a capillary collection versus a standard venous whole blood collection in the GRADE and EDIC studies

Open access

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Background: We compared HbA1c values obtained from capillary blood collection kits versus venous whole blood collections in study participants with type 1 or type 2 diabetes. Methods: A total of 122 subjects, 64 with type 2 diabetes participating in the Glycemia Reduction Approaches in Diabetes: A Comparative Effectiveness (GRADE) Study and 58 with type 1 diabetes from the Epidemiology of Diabetes Interventions and Complications (EDIC) Study, participated in the validation study. Capillary tubes were filled by fingerstick by the participants on the same day as the collection of venous whole blood samples in EDTA-containing test tubes and were mailed to the central laboratory. HbA1c in all samples was measured with the same high-performance liquid chromatography. GRADE participants also completed a questionnaire on the ease of performing capillary collections. Results: Participants from 22 clinical centers (GRADE n = 5, EDIC n = 17) were between 35 and 86 years of age, with 52% male and diverse race/ethnicities. Venous HbA1c results ranged between 5.4–11.9% (35.5–106.6 mmol/mol) with corresponding capillary results ranging between 4.2–11.9% (22.4–106.6 mmol/mol). The venous and capillary results were highly correlated (R 2 = 0.993) and 96.7% differed by ≤0.2% (2.2 mmol/mol). Of participants surveyed, 69% indicated that the instructions and collection were easy to follow and 97% felt the collection method would be easy to do at home. Conclusions: The capillary blood HbA1c results compared well with the conventional venous whole blood results. The capillary kits can be employed in other studies to reduce interruption of critical data collection and potentially to augment clinical care when in-person visits are not possible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0257154

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Distribution of HbA1c values from venous samples.
Fig 1 Distribution of HbA1c values from venous samples.CC BY · PubMed Central
Fig 2 Regression plots of capillary and venous HbA1cs.
Fig 2 Regression plots of capillary and venous HbA1cs.CC BY · PubMed Central
Fig 3 Bland-Altman plots.
Fig 3 Bland-Altman plots.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 22

Metadata

Authors
Nathan, D. M., Krause-Steinrauf, H., Braffett, B. H., Arends, V. L., Younes, N., McGee, P., Lund, C., Johnson, M., Lorenzi, G., Gao, X., Steffes, M. W., Lachin, J. M., the GRADE Research Group, & the DCCT/EDIC Research Group
Affiliations
  • Harvard University (US)
  • George Washington University (US)
  • University of Minnesota (US)
  • HealthPartners (US)
  • University of California San Diego (US)
Corresponding author
Krause-Steinrauf, Heidi
Venue
PLOS ONE
Published
2021-11-15
Volume
16
Issue
11
Pages
e0257154
ISSN
1932-6203 (ISSN-L)
OpenAlex
W3211708690
Cited by
21
References
11
Citations by year
2026: 5 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 4
FWCI
2.42
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Institute of Diabetes and Digestive and Kidney Diseases (U01DK098246, U34DK088043, U01 DK094176, U01 DK094157)
  • american diabetes association
  • national heart, lung, and blood institute
  • centers for disease control and prevention
  • national eye institute
  • national institute of neurological disorders and stroke
  • general clinical research centers program
  • clinical translational science center program
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
Keywords
HbA1c, capillary blood collection, venous whole blood, type 1 diabetes, type 2 diabetes, home blood sampling, method comparison
MeSH terms
Adult, Aged, Aged, 80 and over, Blood Glucose, Blood Specimen Collection, Capillaries, Diabetes Mellitus, Type 1, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Male, Middle Aged

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of central laboratory HbA1c measurements obtained from a capillary collection versus a standard venous whole blood collection in the GRADE and EDIC studies. https://app.cochat.ai/papers/10.1371/journal.pone.0257154
The paper
Nathan, D. M., Krause-Steinrauf, H., Braffett, B. H., Arends, V. L., Younes, N., McGee, P., Lund, C., Johnson, M., Lorenzi, G., Gao, X., Steffes, M. W., Lachin, J. M., the GRADE Research Group, & the DCCT/EDIC Research Group. (2021). Comparison of central laboratory HbA1c measurements obtained from a capillary collection versus a standard venous whole blood collection in the GRADE and EDIC studies. PLOS ONE. https://doi.org/10.1371/journal.pone.0257154

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.