Two-Dimensional Mapping of Copper and Zinc in Liver Sections by Laser Ablation–Inductively Coupled Plasma Mass Spectrometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Metals are not homogeneously distributed in organ tissues. Although most mapping techniques, such as histologic staining methods, have been developed for element imaging on a subcellular level, many suffer from either low precision or poor detection limits. Therefore, small variations in elemental distribution cannot be identified. We developed a method for two-dimensional mapping of trace elements to identify the influence of metabolic zonation by the liver on trace element distribution. Methods: A prepared homogeneous Certified Reference Material (CRM; LGC 7112, pig liver) was used to characterize the laser ablation–inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-MS) in terms of precision. Different isotopes for copper and zinc were monitored, and the use of carbon as an internal standard was investigated to correct for differences in ablation efficiency to identify the most precise mapping technique for liver samples. Results: For the homogeneous CRM, the reproducibility of the copper and zinc signals was ∼3–24% depending on spot size and number of pulses. When carbon was used as an internal standard, the reproducibility was improved significantly. Line scan signals over a length of 1.5 mm were more precise [relative SD (RSD), 1.6–6.1% for copper (63Cu, 65Cu) and zinc (64Zn, 66Zn) depending on the spot size, the scanning speed, and the element]. Thin section of sheep liver achieved precisions of 27–59% (raster scan) and 9–47% (line scan) RSD for copper, whereas the precision for zinc was significantly better: 8–18% (raster scan) and 4–21% (line scan) RSD. Long line scans and two-dimensional element maps of the thin sections revealed the zonation of copper in sheep liver containing extremely low copper concentrations. Conclusion: Elemental mapping of trace elements generated by LA-ICP-MS can be very precise so that small changes in the elemental concentration in the tissue can be detected and nonuniform spatial distribution of the elements in tissues can be established.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metabolic zonation of the liver: Regulation and implications for liver function
Gebhardt, R. (1992) · Pharmacology & Therapeutics · doi:10.1016/0163-7258(92)90055-5 · Cited by 607 · cited 1×
“It is well known that if high copper concentrations are found in the liver, they are not uniformly distributed (17, 18).”
Background
Cited by
In Situ Imaging of Metals in Cells and Tissues
McRae, R., Bagchi, P., Sumalekshmy, S., & Fahrni, C. J. (2009) · Chemical Reviews · doi:10.1021/cr900223a · Cited by 570
Becker, J. S., Matusch, A., Depboylu, C., Dobrowolska, J., & Zoriy, M. V. (2007) · Analytical Chemistry · doi:10.1021/ac0700528 · Cited by 363
Becker, J. S., Zoriy, M. V., Pickhardt, C., Palomero-Gallagher, N., & Zilles, K. (2005) · Analytical Chemistry · doi:10.1021/ac040184q · Cited by 358
Imaging mass spectrometry in microbiology
Watrous, J. D., & Dorrestein, P. C. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2634 · Cited by 338
“LA–ICP IMS provides an analysis of the atomic distributions across the surface of a sample at the parts per million to parts per billion level and has been found to be especially useful in the detection and quantitative analysis of the metal content in biological sample”
MethodBioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)
Becker, J. S., Zoriy, M., Matusch, A., Wu, B., Salber, D., Palm, C., & Becker, J. S. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20239 · Cited by 287
Metadata
- Authors
- Kindness, A., Sekaran, C. N., & Feldmann, J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-11-01
- Volume
- 49
- Issue
- 11
- Pages
- 1916-1923
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2099591385
- Cited by
- 138
- References
- 1
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.