CoChat

Two-Dimensional Mapping of Copper and Zinc in Liver Sections by Laser Ablation–Inductively Coupled Plasma Mass Spectrometry

Kindness, Andrew, Sekaran, Chandra N, Feldmann, Jörg · 2003 · Clinical Chemistry
Cited by 138

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Metals are not homogeneously distributed in organ tissues. Although most mapping techniques, such as histologic staining methods, have been developed for element imaging on a subcellular level, many suffer from either low precision or poor detection limits. Therefore, small variations in elemental distribution cannot be identified. We developed a method for two-dimensional mapping of trace elements to identify the influence of metabolic zonation by the liver on trace element distribution. Methods: A prepared homogeneous Certified Reference Material (CRM; LGC 7112, pig liver) was used to characterize the laser ablation–inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-MS) in terms of precision. Different isotopes for copper and zinc were monitored, and the use of carbon as an internal standard was investigated to correct for differences in ablation efficiency to identify the most precise mapping technique for liver samples. Results: For the homogeneous CRM, the reproducibility of the copper and zinc signals was ∼3–24% depending on spot size and number of pulses. When carbon was used as an internal standard, the reproducibility was improved significantly. Line scan signals over a length of 1.5 mm were more precise [relative SD (RSD), 1.6–6.1% for copper (63Cu, 65Cu) and zinc (64Zn, 66Zn) depending on the spot size, the scanning speed, and the element]. Thin section of sheep liver achieved precisions of 27–59% (raster scan) and 9–47% (line scan) RSD for copper, whereas the precision for zinc was significantly better: 8–18% (raster scan) and 4–21% (line scan) RSD. Long line scans and two-dimensional element maps of the thin sections revealed the zonation of copper in sheep liver containing extremely low copper concentrations. Conclusion: Elemental mapping of trace elements generated by LA-ICP-MS can be very precise so that small changes in the elemental concentration in the tissue can be detected and nonuniform spatial distribution of the elements in tissues can be established.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2003.022046

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 138

Metadata

Authors
Kindness, A., Sekaran, C. N., & Feldmann, J.
Venue
Clinical Chemistry
Published
2003-11-01
Volume
49
Issue
11
Pages
1916-1923
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2099591385
Cited by
138
References
1
FWCI
4.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.