Test Research versus Diagnostic Research
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The diagnostic workup starts with a patient presenting with symptoms or signs suggestive of a particular disease. The workup is commonly a consecutive process starting with medical history and physical examination and simple tests followed by more burdensome and costly diagnostic procedures. Generally, after each test all available results are converted (often implicitly) to a probability of disease, which in turn directs decisions for additional testing or initiation of appropriate treatment. Setting a diagnosis is a multitest or multivariable process of estimating and updating the diagnostic probability of disease presence given combinations of test results. Each test may be more or less burdensome to the patient, time-consuming, and/or costly. Different tests often provide to various degrees the same information because they are all associated with the same underlying disorder. Relevant for physicians is to know which tests are redundant and which have true, independent predictive value for the presence or absence of the target disease. Accordingly, studies of diagnostic accuracy should demonstrate which (subsequent) test results truly increase or decrease the probability of disease presence as estimated from the previous results, and to what extent. Various reviews have demonstrated that the majority of published studies of diagnostic accuracy still have methodologic flaws in design or analysis or provide results with limited practical applicability (1)(2)(3). This has been attributed to the absence of a proper methodologic framework for diagnostic test evaluations as, for example, exists for studies of therapies and etiologic factors and has motivated various researchers to establish frameworks for studies of diagnostic accuracy, such as the recent STARD Initiative (4)(5)(6)(7)(8)(9)(10)(11)(12). In our view, an issue that has received too little attention in most of these methodologic essays is the difference between test research and diagnostic research. By “test research” we refer to studies that follow a single-test or univariable approach, i.e., studies focusing on a particular test to quantify its sensitivity, specificity, likelihood ratio (LR), or area under the ROC curve (ROC area). We call this test research because it merely quantifies the “characteristics” of the test rather than the test’s contribution to estimate the diagnostic probability of disease presence or absence. By “diagnostic research” we refer to studies that aim to quantify a test’s added contribution beyond test results readily available to the physician in determining the presence or absence of a particular disease. Although the multivariable and probabilistic character of medical diagnosis is slowly gaining appreciation in medical research, the majority of studies on diagnostic accuracy may still be regarded as test research (2)(3)(8). We believe that test research has limited applicability to clinical practice. Below we describe why we believe this is the case, provide a brief description of a better approach, and give two clinical examples illustrating the hazards of test research. Finally, we describe the few instances in which test research may be worthwhile. The first reason that test research has limited relevance to practice is the nature of the questions that are usually addressed. The practical utility of estimation of sensitivity, specificity, and LR for a particular test in the diagnosis of a particular disease is not always obvious (7)(13). Consider, for example, the diagnostic workup for patients suspected of deep vein thrombosis (DVT). The relevant research question for patients suspected of DVT would be: “Given patient history and physical examination, which subsequent tests (e.g., d-dimer measurement) truly provide added information to predict the presence or absence of DVT?” The probability of disease presence and quantifying which tests independently contribute to the estimation of this probability should be the objects of study. However, in this respect many studies have aimed only to estimate the sensitivity and specificity of the d-dimer assay. When this is the object of a study, it is only the probability of obtaining a positive or negative test result that is addressed, rather than the probability of disease presence. Moreover, the focus is on the value of a single test rather than on the value of that test in combination with other, previous tests, including patient history and physical examination. We may say that the object of research is the test rather than the (probability of) disease. Hence the term test research. The second reason that results from test research have limited relevance is that a test’s sensitivity, specificity, LR, and ROC area tend to be taken as properties or characteristics of a test. This, however, is a misconception, as we discussed recently (13). It is widely accepted that the predictive values of a test vary across patient populations. However, several studies have empiri
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Clinical Prediction Rules: Applications and Methodological Standards
Wasson, J. H., Sox, H. C., Neff, R. K., & Goldman, L. (1985) · New England Journal of Medicine · doi:10.1056/nejm198509263131306 · Cited by 1,357
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Laupacis, A. (1997) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1997.03540300056034 · Cited by 793
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Moons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Self-citation
Cited by
Systematic reviews: CRD's guidance for undertaking reviews in health care
Tacconelli, E. (2010) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(10)70065-7 · Cited by 3,245
Moons, K. G. M., Kengne, A. P., Woodward, M., Royston, P., Vergouwe, Y., Altman, D. G., & Grobbee, D. E. (2012) · Heart · doi:10.1136/heartjnl-2011-301246 · Cited by 889
Self-citationEvaluation of diagnostic tests when there is no gold standard. A review of methods
Rutjes, A., Reitsma, J., Coomarasamy, A., Khan, K., & Bossuyt, P. (2007) · Health Technology Assessment · doi:10.3310/hta11500 · Cited by 524
Rangaka, M. X., Wilkinson, K. A., Glynn, J. R., Ling, D., Menzies, D., Mwansa-Kambafwile, J., Fielding, K., Wilkinson, R. J., & Pai, M. (2012) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(11)70210-9 · Cited by 476
Comparative accuracy: assessing new tests against existing diagnostic pathways
Bossuyt, P. M., Irwig, L., Craig, J., & Glasziou, P. (2006) · BMJ · doi:10.1136/bmj.332.7549.1089 · Cited by 458
Theron, G., Zijenah, L., Chanda, D., Clowes, P., Rachow, A., Lesosky, M., Bara, W., Mungofa, S., Pai, M., Hoelscher, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62073-5 · Cited by 433
Cowley, L. E., Farewell, D. M., Maguire, S., & Kemp, A. M. (2019) · Diagnostic and Prognostic Research · doi:10.1186/s41512-019-0060-y · Cited by 263
Rutten, F. H., Moons, K. G. M., Cramer, M.-J. M., Grobbee, D. E., Zuithoff, N. P. A., Lammers, A.-W. J., & Hoes, A. W. (2005) · BMJ · doi:10.1136/bmj.38664.661181.55 · Cited by 241
“9 21 22 In our study, an expert panel determined the presence or absence of heart failure as in previous studies.”
Self-citationDiagnostic and prognostic prediction models
Hendriksen, J. M. T., Geersing, G. J., Moons, K. G. M., & de Groot, J. A. H. (2013) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12262 · Cited by 229
Self-citationSample sizes of studies on diagnostic accuracy: literature survey.
Bachmann, L. M., Puhan, M. A., Riet, G. T., & Bossuyt, P. M. (2006) · BMJ · doi:10.1136/bmj.38793.637789.2f · Cited by 184
Quantifying the Added Value of a Diagnostic Test or Marker
Moons, K. G. M., de Groot, J. A. H., Linnet, K., Reitsma, J. B., & Bossuyt, P. M. M. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.182550 · Cited by 152
Self-citation
Metadata
- Authors
- Moons, K. G. M., Biesheuvel, C. J., & Grobbee, D. E.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-03-01
- Volume
- 50
- Issue
- 3
- Pages
- 473-476
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2103492481
- Cited by
- 137
- References
- 9
- FWCI
- 18.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.