Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma
Open accessAbstract
Background: Estradiol (E2) and estrone (E1) measurements form an integral part of the assessment of female reproductive function and have expanding roles in other fields. However, many E1 and E2 immunoassays have limited functional sensitivity, suffer from cross-reactivity, and display poor intermethod agreement. To overcome these problems, we developed a sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) assay for the simultaneous measurement of E1 and E2. Methods: After dansyl chloride derivatization, samples were separated by fast gradient chromatography and injected into a tandem mass spectrometer after formation of positive ions with atmospheric pressure chemical ionization. The limits of detection and quantification, recovery, linearity, precision, and reference intervals were determined, and performance was compared with several immunoassays. Results: Total run time per sample was 5 min. The multiple-reaction monitoring ion pairs were m/z 506/171 for 3-dansyl-estradiol and m/z 504/171 for 3-dansyl-estrone. The limits of detection for E1 and E2 were 12.9 pmol/L (3.5 ng/L) and 10.3 pmol/L (2.8 ng/L), respectively. Interassay imprecision (CV) was 4–20% (n = 20). The limits of quantification (functional sensitivities) for E1 and E2 were 44.1 pmol/L (11.9 ng/L) and 23.2 pmol/L (6.3 ng/L), respectively. The assay was linear to >2200 pmol/L (∼600 ng/L) for each analyte. Recoveries were 93–108% for E1 and 100–110% for E2. No cross-reactivity was observed. Method comparison with several immunoassays revealed that the latter were inaccurate and prone to interferences at low E1 and E2 concentrations. Conclusions: LC-MS/MS allows rapid, simultaneous, sensitive, and accurate quantification of E1 and E2 in human serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 42
- 2001, Horm Res, 56, 38
- 1998, J Clin Endocrinol Metab, 83, 2239
- 2000, Ann Intern Med, 133, 951, 10.7326/0003-4819-133-12-200012190-00010 · DOI · Paper page
- 2002, Crit Rev Toxicol, 32, 445, 10.1080/20024091064291 · DOI
- 2000, Environ Health Perspect, 108, 723, 10.1289/ehp.00108723 · DOI · Paper page
- 2001, Hum Reprod, 16, 1030, 10.1093/humrep/16.5.1030 · DOI · Paper page
- 1995, J Clin Pharmacol, 35, 18S, 10.1002/j.1552-4604.1995.tb04143.x · DOI · Paper page
- 1999, Hum Reprod, 14, 107
- 2001, Fertil Steril, 76, 1185, 10.1016/S0015-0282(01)02893-X · DOI
- 1999, Horm Res, 51, 95
- 1973, Pediatr Res, 7, 901, 10.1203/00006450-197311000-00006 · DOI
- 1986, N Engl J Med, 315, 1115, 10.1056/NEJM198610303151802 · DOI
- 2001, Clin Endocrinol, 55, 789, 10.1046/j.1365-2265.2001.01416.x · DOI
- 2000, J Pediatr Endocrinol Metab, 13, 709
- 1994, J Clin Invest, 94, 2475, 10.1172/JCI117616 · DOI · Paper page
- 2000, Curr Opin Pediatr, 12, 394, 10.1097/00008480-200008000-00020 · DOI
- 2002, Best Pract Res Clin Endocrinol Metab, 16, 139, 10.1053/beem.2001.0186 · DOI
- 2002, JAMA, 287, 216, 10.1001/jama.287.2.216 · DOI · Paper page
- 1997, J Steroid Biochem Mol Biol, 61, 255, 10.1016/S0960-0760(97)80020-9 · doi:10.1016/s0960-0760(97)80020-9
- 2003, Eur J Endocrinol, 148, 67
- 1996, Acta Obstet Gynecol Scand Suppl, 163, 11
- 1984, J Clin Chem Clin Biochem, 22, 551
- 2000, Analyst, 125, 711, 10.1039/a909107f · DOI
- 2000, Rapid Commun Mass Spectrom, 14, 1991, 10.1002/1097-0231(20001115)14:21<1991::AID-RCM125>3.0.CO;2-H · doi:10.1002/1097-0231(20001115)14:21<1991::aid-rcm125>3.0.co;2-h
- 2002, J Mass Spectrom, 37, 1266, 10.1002/jms.397 · DOI
- 2001, Biochem J, 355, 545, 10.1042/bj3550545 · DOI · Paper page
- 2002, Ther Drug Monit, 24, 255, 10.1097/00007691-200204000-00008 · DOI
- 1999, Semin Perinatol, 23, 183, 10.1016/S0146-0005(99)80050-0 · DOI
- 2002, Clin Chem, 48, 1511, 10.1093/clinchem/48.9.1511 · DOI · Paper page
- 2002, Clin Chem, 48, 533, 10.1093/clinchem/48.3.533 · DOI
- 2002, Anal Chem, 74, 4136, 10.1021/ac025712h · DOI · Paper page
- 2003, Clin Chem, 49, 1041, 10.1373/49.7.1041 · DOI · Paper page
- 1999, J Clin Lab Anal, 13, 266, 10.1002/(SICI)1098-2825(1999)13:6<266::AID-JCLA3>3.0.CO;2-# · doi:10.1002/(sici)1098-2825(1999)13:6<266::aid-jcla3>3.0.co;2-#
- 2002, J Assist Reprod Genet, 19, 349, 10.1023/A:1016014810853 · doi:10.1023/a:1016014810853
- 2000, Clin Chem, 46, 734, 10.1093/clinchem/46.5.734 · doi:10.1093/clinchem/46.5.734
- 1997, Clin Chem, 43, 1250, 10.1093/clinchem/43.7.1250 · DOI
- 1998, Clin Chem, 44, 671, 10.1093/clinchem/44.3.671 · DOI
- 1990, Clin Chem, 36, 1769, 10.1093/clinchem/36.10.1769 · DOI
- 1983, Adv Chromatogr, 21, 1
- 2003, Rapid Commun Mass Spectrom, 17, 56, 10.1002/rcm.819 · doi:10.1002/rcm.819
- 2002, Clin Chem, 48, 364, 10.1093/clinchem/48.2.364 · doi:10.1093/clinchem/48.2.364
- 1998, Analyst, 123, 2605, 10.1039/a805224g · DOI
Cited by
Steroid Hormone Analysis by Tandem Mass Spectrometry
Soldin, S. J., & Soldin, O. P. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2007.100008 · Cited by 264
Sikaris, K., McLachlan, R. I., Kazlauskas, R., de Kretser, D., Holden, C. A., & Handelsman, D. J. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0962 · Cited by 259
Rothman, M. S., Carlson, N. E., Xu, M., Wang, C., Swerdloff, R., Lee, P., Goh, V. H. H., Ridgway, E. C., & Wierman, M. E. (2011) · Steroids · doi:10.1016/j.steroids.2010.10.010 · Cited by 248
Courant, F., Aksglaede, L., Antignac, J.-P., Monteau, F., Sorensen, K., Andersson, A.-M., Skakkebaek, N. E., Juul, A., & Bizec, B. L. (2010) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-1140 · Cited by 172
Eisenhofer, G., Peitzsch, M., Kaden, D., Langton, K., Pamporaki, C., Masjkur, J., Tsatsaronis, G., Mangelis, A., Williams, T. A., Reincke, M., et al. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.05.002 · Cited by 171
Metadata
- Authors
- Nelson, R. E., Grebe, S. K., O’Kane, D. J., & Singh, R. J.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-02-01
- Volume
- 50
- Issue
- 2
- Pages
- 373-384
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2097563817
- Cited by
- 359
- References
- 0
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma. https://app.cochat.ai/papers/10.1373/clinchem.2003.025478
- The paper
- Nelson, R. E., Grebe, S. K., O’Kane, D. J., & Singh, R. J. (2004). Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma. Clinical Chemistry. https://doi.org/10.1373/clinchem.2003.025478
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.