Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma

Open access
Nelson, Robert E, Grebe, Stefan K, O’Kane, Dennis J, Singh, Ravinder J·2004·Clinical Chemistry

Abstract

Background: Estradiol (E2) and estrone (E1) measurements form an integral part of the assessment of female reproductive function and have expanding roles in other fields. However, many E1 and E2 immunoassays have limited functional sensitivity, suffer from cross-reactivity, and display poor intermethod agreement. To overcome these problems, we developed a sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) assay for the simultaneous measurement of E1 and E2. Methods: After dansyl chloride derivatization, samples were separated by fast gradient chromatography and injected into a tandem mass spectrometer after formation of positive ions with atmospheric pressure chemical ionization. The limits of detection and quantification, recovery, linearity, precision, and reference intervals were determined, and performance was compared with several immunoassays. Results: Total run time per sample was 5 min. The multiple-reaction monitoring ion pairs were m/z 506/171 for 3-dansyl-estradiol and m/z 504/171 for 3-dansyl-estrone. The limits of detection for E1 and E2 were 12.9 pmol/L (3.5 ng/L) and 10.3 pmol/L (2.8 ng/L), respectively. Interassay imprecision (CV) was 4–20% (n = 20). The limits of quantification (functional sensitivities) for E1 and E2 were 44.1 pmol/L (11.9 ng/L) and 23.2 pmol/L (6.3 ng/L), respectively. The assay was linear to >2200 pmol/L (∼600 ng/L) for each analyte. Recoveries were 93–108% for E1 and 100–110% for E2. No cross-reactivity was observed. Method comparison with several immunoassays revealed that the latter were inaccurate and prone to interferences at low E1 and E2 concentrations. Conclusions: LC-MS/MS allows rapid, simultaneous, sensitive, and accurate quantification of E1 and E2 in human serum.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2003.025478

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 42

  1. 2001, Horm Res, 56, 38
  2. 1998, J Clin Endocrinol Metab, 83, 2239
  3. 2000, Ann Intern Med, 133, 951, 10.7326/0003-4819-133-12-200012190-00010 · DOI · Paper page
  4. 2002, Crit Rev Toxicol, 32, 445, 10.1080/20024091064291 · DOI
  5. 2000, Environ Health Perspect, 108, 723, 10.1289/ehp.00108723 · DOI · Paper page
  6. 2001, Hum Reprod, 16, 1030, 10.1093/humrep/16.5.1030 · DOI · Paper page
  7. 1995, J Clin Pharmacol, 35, 18S, 10.1002/j.1552-4604.1995.tb04143.x · DOI · Paper page
  8. 1999, Hum Reprod, 14, 107
  9. 2001, Fertil Steril, 76, 1185, 10.1016/S0015-0282(01)02893-X · DOI
  10. 1999, Horm Res, 51, 95
  11. 1973, Pediatr Res, 7, 901, 10.1203/00006450-197311000-00006 · DOI
  12. 1986, N Engl J Med, 315, 1115, 10.1056/NEJM198610303151802 · DOI
  13. 2001, Clin Endocrinol, 55, 789, 10.1046/j.1365-2265.2001.01416.x · DOI
  14. 2000, J Pediatr Endocrinol Metab, 13, 709
  15. 1994, J Clin Invest, 94, 2475, 10.1172/JCI117616 · DOI · Paper page
  16. 2000, Curr Opin Pediatr, 12, 394, 10.1097/00008480-200008000-00020 · DOI
  17. 2002, Best Pract Res Clin Endocrinol Metab, 16, 139, 10.1053/beem.2001.0186 · DOI
  18. 2002, JAMA, 287, 216, 10.1001/jama.287.2.216 · DOI · Paper page
  19. 1997, J Steroid Biochem Mol Biol, 61, 255, 10.1016/S0960-0760(97)80020-9 · doi:10.1016/s0960-0760(97)80020-9
  20. 2003, Eur J Endocrinol, 148, 67
  21. 1996, Acta Obstet Gynecol Scand Suppl, 163, 11
  22. 1984, J Clin Chem Clin Biochem, 22, 551
  23. 2000, Analyst, 125, 711, 10.1039/a909107f · DOI
  24. 2000, Rapid Commun Mass Spectrom, 14, 1991, 10.1002/1097-0231(20001115)14:21<1991::AID-RCM125>3.0.CO;2-H · doi:10.1002/1097-0231(20001115)14:21<1991::aid-rcm125>3.0.co;2-h
  25. 2002, J Mass Spectrom, 37, 1266, 10.1002/jms.397 · DOI
  26. 2001, Biochem J, 355, 545, 10.1042/bj3550545 · DOI · Paper page
  27. 2002, Ther Drug Monit, 24, 255, 10.1097/00007691-200204000-00008 · DOI
  28. 1999, Semin Perinatol, 23, 183, 10.1016/S0146-0005(99)80050-0 · DOI
  29. 2002, Clin Chem, 48, 1511, 10.1093/clinchem/48.9.1511 · DOI · Paper page
  30. 2002, Clin Chem, 48, 533, 10.1093/clinchem/48.3.533 · DOI
  31. 2002, Anal Chem, 74, 4136, 10.1021/ac025712h · DOI · Paper page
  32. 2003, Clin Chem, 49, 1041, 10.1373/49.7.1041 · DOI · Paper page
  33. 1999, J Clin Lab Anal, 13, 266, 10.1002/(SICI)1098-2825(1999)13:6<266::AID-JCLA3>3.0.CO;2-# · doi:10.1002/(sici)1098-2825(1999)13:6<266::aid-jcla3>3.0.co;2-#
  34. 2002, J Assist Reprod Genet, 19, 349, 10.1023/A:1016014810853 · doi:10.1023/a:1016014810853
  35. 2000, Clin Chem, 46, 734, 10.1093/clinchem/46.5.734 · doi:10.1093/clinchem/46.5.734
  36. 1997, Clin Chem, 43, 1250, 10.1093/clinchem/43.7.1250 · DOI
  37. 1998, Clin Chem, 44, 671, 10.1093/clinchem/44.3.671 · DOI
  38. 1990, Clin Chem, 36, 1769, 10.1093/clinchem/36.10.1769 · DOI
  39. 1983, Adv Chromatogr, 21, 1
  40. 2003, Rapid Commun Mass Spectrom, 17, 56, 10.1002/rcm.819 · doi:10.1002/rcm.819
  41. 2002, Clin Chem, 48, 364, 10.1093/clinchem/48.2.364 · doi:10.1093/clinchem/48.2.364
  42. 1998, Analyst, 123, 2605, 10.1039/a805224g · DOI

Cited by

See all 359

Metadata

Authors
Nelson, R. E., Grebe, S. K., O’Kane, D. J., & Singh, R. J.
Venue
Clinical Chemistry
Published
2004-02-01
Volume
50
Issue
2
Pages
373-384
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2097563817
Cited by
359
References
0
FWCI
6.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma. https://app.cochat.ai/papers/10.1373/clinchem.2003.025478
The paper
Nelson, R. E., Grebe, S. K., O’Kane, D. J., & Singh, R. J. (2004). Liquid Chromatography–Tandem Mass Spectrometry Assay for Simultaneous Measurement of Estradiol and Estrone in Human Plasma. Clinical Chemistry. https://doi.org/10.1373/clinchem.2003.025478

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.