CoChat

Between-Lot Variation in External Quality Assessment of Glucose: Clinical Importance and Effect on Participant Performance Evaluation

Open access
Kristensen, Gunn BB, Christensen, Nina Gade, Thue, Geir, Sandberg, Sverre · 2005 · Clinical Chemistry
Cited by 70

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: External quality assessment schemes (EQAS) are conducted to evaluate user performance (participant assessment) and to assess different methods and instruments (method assessment). The quality of control materials is crucial to achieving these goals. Inconsistencies in between-lot variations detected by use of different control and sample materials may affect EQAS outcomes. Methods: For the Accu-Chek Sensor, Precision Xtra, Ascensia Elite, and HemoCue 201 glucometers, 3 different lots of glucose strips were used with each instrument. Method assessment results from analysis of capillary blood and 3 control materials were used to calculate between-lot differences. A simulation study was performed to evaluate the effect of between-lot variation on participant assessment results. Results: With the Precision Xtra, the results obtained with EQA control material mirrored those obtained with capillary blood, but for the other instruments, we found between-lot differences of as much as 1.3 mmol/L, which were substantially greater than those found with capillary blood and of clinical importance at decision limits. The simulation study showed an effect on participant assessment results related to the target values, with the percentage of poor results decreasing (38%, 10%, and 4%) with the use of common, method-specific, and lot-specific target values, respectively. Conclusions: Between-lot variation may influence participant EQA results for participant and method assessments. The clinical relevance of between-lot variation discovered in EQAS using noncommutable control materials should be examined by use of native blood samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2005.049080

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 70

Metadata

Authors
Kristensen, G. B., Christensen, N. G., Thue, G., & Sandberg, S.
Venue
Clinical Chemistry
Published
2005-09-01
Volume
51
Issue
9
Pages
1632-1636
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2067308906
Cited by
70
References
3
FWCI
2.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Between-Lot Variation in External Quality Assessment of Glucose: Clinical Importance and Effect on Participant Performance Evaluation. https://app.cochat.ai/papers/10.1373/clinchem.2005.049080
The paper
Kristensen, G. B., Christensen, N. G., Thue, G., & Sandberg, S. (2005). Between-Lot Variation in External Quality Assessment of Glucose: Clinical Importance and Effect on Participant Performance Evaluation. Clinical Chemistry. https://doi.org/10.1373/clinchem.2005.049080

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.