Novel Biosensor–Based Analytic Device for the Detection of Anti–Double-Stranded DNA Antibodies
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Background: Patients with systemic lupus erythematosus (SLE) develop a wide variety of serologic manifestations, including double-stranded DNA autoantibodies (anti-dsDNA). The determination of the potentially pathogenic autoantibodies is diagnostically relevant. Methods: We developed a novel surface plasmon resonance (SPR) biosensor chip for studies of dsDNA and anti-dsDNA binding. A synthetic oligonucleotide was coupled to biotinylated human transferrin, hybridized with the complementary antistrand, and ligated with a human recombinant dsDNA fragment 233 bp in length. After surface immobilization of this antigenic construct, diluted sera from SLE patients and healthy donors were analyzed with the resulting SPR biosensor system. Results: This SPR biosensor allowed specific detection of anti-dsDNA. In pilot experiments, sera from SLE patients were distinguished from control sera. We also confirmed the specificity of this biosensor by supplementing anti-dsDNA–positive sera with salmon sperm DNA, which blocked the surface binding of anti-dsDNA in a concentration-dependent manner. Conclusions: An SPR biosensor monitors interactions in real time under homogeneous conditions, providing information about binding kinetics and affinities. Its applicability critically depends on the design of the solid-state surface of the sensor chips. Covalently immobilizing dsDNA as the antigen to the surface in a flow-through cell assured maximal stability for multiple serum injections and regeneration cycles. This technique, which adds a new analytic quality to existing methods, may be beneficial in the diagnosis and clinical monitoring of SLE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The use of laboratory tests in the diagnosis of SLE
Egner, W. (2000) · Journal of Clinical Pathology · doi:10.1136/jcp.53.6.424 · Cited by 316
Swaak, T., & Smeenk, R. (1985) · Annals of the Rheumatic Diseases · doi:10.1136/ard.44.4.245 · Cited by 89 · cited 1×
“Both the detection of antinuclear antibodies by immunofluorescence and findings of “antibodies to native DNA in abnormal titer” (American College of Rheumatology criterion 10.b) are of high diagnostic significance and are considered specific (7) and early ( 8 ) markers for SLE.”
BackgroundVillalta, D., Romelli, P. B., Savina, C., Bizzaro, N., Tozzoli, R., Tonutti, E., Ghirardello, A., & Doria, A. (2003) · Lupus · doi:10.1191/0961203303lu277oa · Cited by 45 · cited 1×
“Avidity has been discussed repeatedly in the literature ( 16 ) but still remains a subject of controversy.”
BackgroundThe binding of antihistone antibodies to crithidia luciliae kinetoplasts is growth cycle‐dependent
Deng, J., Sontheimer, R. D., Lipscomb, M. F., & Gilliam, J. N. (1985) · Arthritis & Rheumatism · doi:10.1002/art.1780280210 · Cited by 25 · cited 1×
“In this respect, this method contrasts with the C. luciliae indirect immunofluorescence technique, in which histone impurities may lead to crossreactivity ( 21 ), and with the Farr assay, in which radiolysis may lead to DNA decomposition (22).”
Method
Cited by
Surface Plasmon Resonance Clinical Biosensors for Medical Diagnostics
Masson, J.-F. (2017) · ACS Sensors · doi:10.1021/acssensors.6b00763 · Cited by 663
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
TELES, F., & FONSECA, L. (2008) · Talanta · doi:10.1016/j.talanta.2008.07.024 · Cited by 405
Mummert, E., Fritzler, M. J., Sjöwall, C., Bentow, C., & Mahler, M. (2018) · Journal of Immunological Methods · doi:10.1016/j.jim.2018.05.014 · Cited by 86
Fiegel, F., Buhl, A., Jaekel, H.-P., Werle, E., Schmolke, M., Ollert, M., & Luppa, P. (2010) · Lupus · doi:10.1177/0961203310369681 · Cited by 24
Self-citation
Metadata
- Authors
- Buhl, A., Metzger, J. H., Heegaard, N. H. H., von Landenberg, P., Fleck, M., & Luppa, P. B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-02-01
- Volume
- 53
- Issue
- 2
- Pages
- 334-341
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2014835004
- Cited by
- 47
- References
- 4
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.