CoChat

Development of a Homogeneous Assay to Measure Remnant Lipoprotein Cholesterol

Miyauchi, Kazuhito, Kayahara, Norihiko, Ishigami, Masato, Kuwata, Hideyuki, Mori, Hideharu, Sugiuchi, Hiroyuki, Irie, Tetsumi, Tanaka, Akira, Yamashita, Shizuya, Yamamura, Taku · 2007 · Clinical Chemistry
Cited by 56

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: Quantification of triglyceride-rich lipoprotein (TRL) remnants is useful for risk assessment of coronary artery disease and the diagnosis of type III hyperlipoproteinemia. Although an immunoseparation procedure for remnant-like particle cholesterol has been evaluated extensively in recent years, available methods for measuring TRL remnants have not achieved wide use in routine laboratory practice, suggesting a need for a homogeneous assay that can measure TRL remnant cholesterol in serum or plasma without pretreatment. Methods: We screened for suitable surfactants that exhibited favorable selectivity toward the VLDL remnant (VLDLR) fraction, including intermediate-density lipoproteins (IDLs). We investigated the principal characteristics of this assay by gel filtration of lipoproteins and their particle size distribution. We developed a simple assay and evaluated its performance with the Hitachi-7170 analyzer. Results: Polyoxyethylene-polyoxybutylene block copolymer (POE-POB) exhibited favorable selectivity toward VLDLR and IDL fractions. POE-POB removed apolipoprotein (apo) E and apo C-III from IDL particles in the presence of cholesterol esterase (CHER), and the particle size distribution of IDLs became smaller after the reaction. These results revealed that IDL particles are specifically modified in the presence of CHER and POE-POB, making their component cholesterol available for enzymatic assay. Addition of phospholipase D improved the reactivity toward chylomicron remnants (CMRs). We found a high correlation [y = 1.018x− 0.01 mmol/L, r = 0.962 (n = 160)] between the proposed assay and the immunoseparation assay in serum from healthy individuals. Conclusion: The homogeneous assay described in this report can measure TRL remnant cholesterol, including CMRs, VLDLRs, and IDLs, with high sensitivity and specificity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2007.092296

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 56

Metadata

Authors
Miyauchi, K., Kayahara, N., Ishigami, M., Kuwata, H., Mori, H., Sugiuchi, H., Irie, T., Tanaka, A., Yamashita, S., & Yamamura, T.
Venue
Clinical Chemistry
Published
2007-12-01
Volume
53
Issue
12
Pages
2128-2135
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2101383059
Cited by
56
References
4
FWCI
4.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.