CoChat

State-of-the-Art of Serum Testosterone Measurement by Isotope Dilution–Liquid Chromatography– Tandem Mass Spectrometry

Open access
Thienpont, Linda M, Van Uytfanghe, Katleen, Blincko, Stuart, Ramsay, Carol S, Xie, Hui, Doss, Robert C, Keevil, Brian G, Owen, Laura J, Rockwood, Alan L, Kushnir, Mark M, Chun, Kelly Y, Chandler, Donald W, Field, Helen P, Sluss, Patrick M · 2008 · Clinical Chemistry
Cited by 144

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background: The recent interest of clinical laboratories in developing serum testosterone assays based on isotope dilution–liquid chromatography–tandem mass spectrometry (ID-LC-MS/MS) stems from the lack of accuracy of direct immunoassays. In this study, we assessed the accuracy and state of standardization (traceability) of 4 published ID-LC-MS/MS procedures in a method comparison with an ID–gas chromatography (GC)–MS reference measurement procedure listed in the database of the Joint Committee for Traceability in Laboratory Medicine. Methods: The study used 58 specimens from different patient categories. Each specimen was measured in triplicate (ID-LC-MS/MS) and quadruplicate (ID-GC-MS) in independent runs. Results: The testosterone concentrations by ID-GC-MS were 0.2–4.4 nmol/L (women), 0.2–2.0 nmol/L (hypogonadal man), and 10.1–31.3 nmol/L (normogonadal men). For ID-GC-MS, the CV was nearly constant, with a median of 1.0%; for ID-LC-MS/MS, it was concentration-dependent, with a median of up to 8%. Weighted Deming regression gave mean slopes, intercepts, and correlation coefficients of 0.90–1.11, −0.055–0.013 nmol/L, and 0.993–0.997, respectively. The % difference plot showed between 7% and 26% of the results outside a total error limit of 14%, with median deviations from ID-GC-MS between −9.6 and 0.4%. Conclusions: This study demonstrated fairly good accuracy and standardization of the tested ID-LC-MS/MS procedures. Performance differences between procedures were evident in some instances, due to improper calibration and between-run calibration control. This emphasizes the need for thorough validation, including traceability, of new ID-LC-MS/MS procedures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2008.105841

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 144

Metadata

Authors
Thienpont, L. M., Van Uytfanghe, K., Blincko, S., Ramsay, C. S., Xie, H., Doss, R. C., Keevil, B. G., Owen, L. J., Rockwood, A. L., Kushnir, M. M., Chun, K. Y., Chandler, D. W., Field, H. P., & Sluss, P. M.
Venue
Clinical Chemistry
Published
2008-08-01
Volume
54
Issue
8
Pages
1290-1297
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2145282901
Cited by
144
References
7
FWCI
10.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: State-of-the-Art of Serum Testosterone Measurement by Isotope Dilution–Liquid Chromatography– Tandem Mass Spectrometry. https://app.cochat.ai/papers/10.1373/clinchem.2008.105841
The paper
Thienpont, L. M., Van Uytfanghe, K., Blincko, S., Ramsay, C. S., Xie, H., Doss, R. C., Keevil, B. G., Owen, L. J., Rockwood, A. L., Kushnir, M. M., Chun, K. Y., Chandler, D. W., Field, H. P., & Sluss, P. M. (2008). State-of-the-Art of Serum Testosterone Measurement by Isotope Dilution–Liquid Chromatography– Tandem Mass Spectrometry. Clinical Chemistry. https://doi.org/10.1373/clinchem.2008.105841

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.