The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Liquid Chromatography–Tandem Mass Spectrometry Assay for Androstenedione, Dehydroepiandrosterone, and Testosterone with Pediatric and Adult Reference Intervals
Abstract
Background: Measurement of serum androgens is important in adult, geriatric, pediatric endocrinology, and oncology patients. We developed a liquid chromatography—tandem mass spectrometry (LC-MS/MS) assay for simultaneous measurement of androstenedione, dehydroepiandrosterone (DHEA), and testosterone in these patients. Methods: We spiked 200 μL of serum or plasma with isotope-labeled internal standards and performed extraction with methyl t-butyl ether. We then derivatized the extracts with hydroxylamine and analyzed them by LC-MS/MS using a 2-dimensional chromatographic separation with a 3.5-min analysis time. Results: Total imprecision for each analyte was <11.2%. Limits of quantification were 10, 50, and 10 ng/L for androstenedione, DHEA, and testosterone, respectively. Reference intervals were established for children (age 6 months to 17 years), men, and women. Androstenedione and DHEA concentrations were lowest in 2- to 3-year-old children. Adult concentrations were achieved in girls at Tanner stage 3 and in boys at Tanner stage 4–5. In premenopausal and (postmenopausal) women the median concentrations of androstenedione, DHEA, and testosterone were 810 (360), 3000 (1670), 270 (180) ng/L, respectively. In postmenopausal women, concentrations of testosterone were age independent, whereas androstenedione and DHEA concentrations decreased with age. In men the median concentrations of androstenedione, DHEA, and testosterone were 440, 2000, and 3700 ng/L, respectively. In men older than 40 years, median concentrations decreased at rates of 5%, 10%, and 20% per decade for androstenedione, DHEA, and testosterone, respectively. Conclusions: This LC-MS/MS method has the required lower limit of quantification and specificity for analysis of endogenous concentrations of androgens in all groups studied. Reference intervals were established for healthy children and adults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Williams Textbook of Endocrinology
(2016) · Elsevier eBooks · doi:10.1016/c2013-0-15980-6 · Cited by 3,711
Ion Suppression in Mass Spectrometry
Annesley, T. M. (2003) · Clinical Chemistry · doi:10.1373/49.7.1041 · Cited by 1,591
Congenital Adrenal Hyperplasia
(1987) · New England Journal of Medicine · doi:10.1056/nejm198711263172211 · Cited by 1,409
Congenital adrenal hyperplasia
Speiser, P. W., & White, P. C. (2003) · New England Journal of Medicine · doi:10.1056/nejmra021561 · Cited by 1,405
Rosner, W., Auchus, R. J., Azziz, R., Sluss, P. M., & Raff, H. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1864 · Cited by 1,176
Carel, J.-C., & Léger, J. (2008) · New England Journal of Medicine · doi:10.1056/nejmcp0800459 · Cited by 761
Taieb, J., Mathian, B., Millot, F., Patricot, M.-C., Mathieu, E., Queyrel, N., Lacroix, I., Somma-Delpero, C., & Boudou, P. (2003) · Clinical Chemistry · doi:10.1373/49.8.1381 · Cited by 640
Wang, C., Catlin, D. H., Demers, L. M., Starcevic, B., & Swerdloff, R. S. (2004) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-031287 · Cited by 580
Incorrect least-squares regression coefficients in method-comparison analysis.
Cornbleet, P. J., & Gochman, N. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.3.432 · Cited by 573
A robust approach to reference interval estimation and evaluation
Horn, P. S., Pesce, A. J., & Copeland, B. E. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.622 · Cited by 272
Cited by
Dumesic, D. A., Oberfield, S. E., Stener-Victorin, E., Marshall, J. C., Laven, J. S., & Legro, R. S. (2015) · Endocrine Reviews · doi:10.1210/er.2015-1018 · Cited by 1,020
Circulating Testosterone as the Hormonal Basis of Sex Differences in Athletic Performance
Handelsman, D. J., Hirschberg, A. L., & Bermon, S. (2018) · Endocrine Reviews · doi:10.1210/er.2018-00020 · Cited by 594
Escobar-Morreale, H. F., Carmina, E., Dewailly, D., Gambineri, A., Kelestimur, F., Moghetti, P., Pugeat, M., Qiao, J., Wijeyaratne, C. N., Witchel, S. F., et al. (2012) · Human Reproduction Update · doi:10.1093/humupd/dmr042 · Cited by 494
Androgen therapy in women: a reappraisal: an Endocrine Society Clinical Practice Guideline
Wierman, M. E., Arlt, W., Basson, R., Davis, S. R., Miller, K. K., Murad, M. H., Rosner, W., & Santoro, N. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2260 · Cited by 363
O'Reilly, M. W., Taylor, A. E., Crabtree, N. J., Hughes, B. A., Capper, F., Crowley, R. K., Stewart, P. M., Tomlinson, J. W., & Arlt, W. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-3399 · Cited by 283
Metadata
- Authors
- Kushnir, M. M., Blamires, T., Rockwood, A. L., Roberts, W. L., Yue, B., Erdogan, E., Bunker, A. M., & Meikle, A. W.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-07-01
- Volume
- 56
- Issue
- 7
- Pages
- 1138-1147
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2162895515
- Cited by
- 283
- References
- 34
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liquid Chromatography–Tandem Mass Spectrometry Assay for Androstenedione, Dehydroepiandrosterone, and Testosterone with Pediatric and Adult Reference Intervals. https://app.cochat.ai/papers/10.1373/clinchem.2010.143222
- The paper
- Kushnir, M. M., Blamires, T., Rockwood, A. L., Roberts, W. L., Yue, B., Erdogan, E., Bunker, A. M., & Meikle, A. W. (2010). Liquid Chromatography–Tandem Mass Spectrometry Assay for Androstenedione, Dehydroepiandrosterone, and Testosterone with Pediatric and Adult Reference Intervals. Clinical Chemistry. https://doi.org/10.1373/clinchem.2010.143222
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.