CoChat

Selected Reaction Monitoring–Mass Spectrometric Immunoassay Responsive to Parathyroid Hormone and Related Variants

Lopez, Mary F, Rezai, Taha, Sarracino, David A, Prakash, Amol, Krastins, Bryan, Athanas, Michael, Singh, Ravinder J, Barnidge, David R, Oran, Paul, Borges, Chad, Nelson, Randall W · 2010 · Clinical Chemistry
Cited by 131

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background: Parathyroid hormone (PTH) assays able to distinguish between full-length PTH (PTH1–84) and N-terminally truncated PTH (PTH7–84) are of increasing significance in the accurate diagnosis of endocrine and osteological diseases. We describe the discovery of new N-terminal and C-terminal PTH variants and the development of selected reaction monitoring (SRM)-based immunoassays specifically designed for the detection of full-length PTH [amino acid (aa)1–84] and 2 N-terminal variants, aa7–84 and aa34–84. Methods: Preparation of mass spectrometric immunoassay pipettor tips and MALDI-TOF mass spectrometric analysis were carried out as previously described. We used novel software to develop SRM assays on a triple-quadrupole mass spectrometer. Heavy isotope-labeled versions of target peptides were used as internal standards. Results: Top-down analysis of samples from healthy individuals and renal failure patients revealed numerous PTH variants, including previously unidentified aa28–84, aa48–84, aa34–77, aa37–77, and aa38–77. Quantitative SRM assays were developed for PTH1–84, PTH7–84, and variant aa34–84. Peptides exhibited linear responses (R2 = 0.90–0.99) relative to recombinant human PTH concentration limits of detection for intact PTH of 8 ng/L and limits of quantification of 16–31 ng/L depending on the peptide. Standard error of analysis for all triplicate measurements was 3%–12% for all peptides, with <5% chromatographic drift between replicates. The CVs of integrated areas under the curve for 54 separate measurements of heavy peptides were 5%–9%. Conclusions: Mass spectrometric immunoassays identified new clinical variants of PTH and provided a quantitative assay for these and previously identified forms of PTH.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2009.137323

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 131

Metadata

Authors
Lopez, M. F., Rezai, T., Sarracino, D. A., Prakash, A., Krastins, B., Athanas, M., Singh, R. J., Barnidge, D. R., Oran, P., Borges, C., & Nelson, R. W.
Venue
Clinical Chemistry
Published
2010-02-01
Volume
56
Issue
2
Pages
281-290
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W1973182209
Cited by
131
References
1
FWCI
5.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selected Reaction Monitoring–Mass Spectrometric Immunoassay Responsive to Parathyroid Hormone and Related Variants. https://app.cochat.ai/papers/10.1373/clinchem.2009.137323
The paper
Lopez, M. F., Rezai, T., Sarracino, D. A., Prakash, A., Krastins, B., Athanas, M., Singh, R. J., Barnidge, D. R., Oran, P., Borges, C., & Nelson, R. W. (2010). Selected Reaction Monitoring–Mass Spectrometric Immunoassay Responsive to Parathyroid Hormone and Related Variants. Clinical Chemistry. https://doi.org/10.1373/clinchem.2009.137323

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.