CoChat

Biological Variation and Reference Change Value of High-Sensitivity Troponin T in Healthy Individuals during Short and Intermediate Follow-up Periods

Open access
Frankenstein, Lutz, Wu, Alan HB, Hallermayer, Klaus, Wians, Frank H, Giannitsis, Evangelos, Katus, Hugo A · 2011 · Clinical Chemistry
Cited by 126

The DOI matches its Crossref record.

Abstract

BACKGROUND: Acute myocardial infarction is defined by a troponin concentration >99th percentile with an acute increase and/or decrease, the magnitude of which has not yet been well defined. To aid the interpretation of changes in cardiac troponin concentration, we sought to establish biological variation and reference change values (RCVs) by applying both the normal and lognormal approaches for cardiac troponin T (cTnT) sampled at hourly and weekly intervals in healthy individuals and measured on the Roche E 170 and Elecsys® 2010 automated platforms. METHODS: High-sensitivity cTnT (hsTnT) was measured at baseline, and after 1, 2, 3, and 4 h and after 1, 2, 3, and 4 weeks in 20 and 17 healthy individuals, respectively. A healthy status was established by physical examination, MRI analysis at rest and during dobutamine stress, lung function testing, and blood sample testing. RESULTS: Hourly total and within-individual CVs were 18% and 15%, respectively, for the E 170 assay, and 24% and 21%, respectively, for the Elecsys 2010 assay. Weekly total and within-individual CVs for these assays were 32% and 31%, respectively, for the E 170 assay, and 32% and 30%, respectively, for the Elecsys 2010 assay. The RCVs for the E 170 and Elecsys 2010 assays were ±46% and ±62% (hourly), respectively, and ±87% and ±86% (weekly), respectively. The corresponding lognormal values were +64%/−39% and +90%/−47% (hourly), and +138%/−58% and +135%/−58% (weekly). CONCLUSIONS: RCVs appear attractive for interpreting hsTnT results. The short-term biological variation of hsTnT is low but becomes somewhat more important at intermediate sampling intervals. Knowledge of this variation is important for interpreting results from patients in whom cTnT values increase from low concentrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2010.158964

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 126

Metadata

Authors
Frankenstein, L., Wu, A. H., Hallermayer, K., Wians, F. H., Giannitsis, E., & Katus, H. A.
Venue
Clinical Chemistry
Published
2011-07-01
Volume
57
Issue
7
Pages
1068-1071
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2105883854
Cited by
126
References
0
FWCI
10.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biological Variation and Reference Change Value of High-Sensitivity Troponin T in Healthy Individuals during Short and Intermediate Follow-up Periods. https://app.cochat.ai/papers/10.1373/clinchem.2010.158964
The paper
Frankenstein, L., Wu, A. H., Hallermayer, K., Wians, F. H., Giannitsis, E., & Katus, H. A. (2011). Biological Variation and Reference Change Value of High-Sensitivity Troponin T in Healthy Individuals during Short and Intermediate Follow-up Periods. Clinical Chemistry. https://doi.org/10.1373/clinchem.2010.158964

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.