Biological Variation and Reference Change Value of High-Sensitivity Troponin T in Healthy Individuals during Short and Intermediate Follow-up Periods
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Acute myocardial infarction is defined by a troponin concentration >99th percentile with an acute increase and/or decrease, the magnitude of which has not yet been well defined. To aid the interpretation of changes in cardiac troponin concentration, we sought to establish biological variation and reference change values (RCVs) by applying both the normal and lognormal approaches for cardiac troponin T (cTnT) sampled at hourly and weekly intervals in healthy individuals and measured on the Roche E 170 and Elecsys® 2010 automated platforms. METHODS: High-sensitivity cTnT (hsTnT) was measured at baseline, and after 1, 2, 3, and 4 h and after 1, 2, 3, and 4 weeks in 20 and 17 healthy individuals, respectively. A healthy status was established by physical examination, MRI analysis at rest and during dobutamine stress, lung function testing, and blood sample testing. RESULTS: Hourly total and within-individual CVs were 18% and 15%, respectively, for the E 170 assay, and 24% and 21%, respectively, for the Elecsys 2010 assay. Weekly total and within-individual CVs for these assays were 32% and 31%, respectively, for the E 170 assay, and 32% and 30%, respectively, for the Elecsys 2010 assay. The RCVs for the E 170 and Elecsys 2010 assays were ±46% and ±62% (hourly), respectively, and ±87% and ±86% (weekly), respectively. The corresponding lognormal values were +64%/−39% and +90%/−47% (hourly), and +138%/−58% and +135%/−58% (weekly). CONCLUSIONS: RCVs appear attractive for interpreting hsTnT results. The short-term biological variation of hsTnT is low but becomes somewhat more important at intermediate sampling intervals. Knowledge of this variation is important for interpreting results from patients in whom cTnT values increase from low concentrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fourth universal definition of myocardial infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., White, H. D., ESC Scientific Document Group, Thygesen, K., Alpert, J. S., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy462 · Cited by 5,880
Self-citationFourth Universal Definition of Myocardial Infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., & White, H. D. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.08.1038 · Cited by 4,118
Fourth Universal Definition of Myocardial Infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., White, H. D., & The Executive Group on behalf of the Joint European Society of Cardiology (ESC)/American College of Cardiology (ACC)/American Heart Association (AHA)/World Heart Federation (WHF) Task Force for the Universal Definition of Myocardial Infarction (2018) · Circulation · doi:10.1161/cir.0000000000000617 · Cited by 3,799
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.165795 · Cited by 861
“반면, Table 3은 1개의 연구[36] 외에는 모 두 Wu 등이 초창기에 수집한 것과 동일한[35], 단기변이의 측정에 사용된 검체에서 hs 검사법 5개의 생물학적 변이 특성을 보여주고 있다[35-38].”
How to use high-sensitivity cardiac troponins in acute cardiac care
Thygesen, K., Mair, J., Giannitsis, E., Mueller, C., Lindahl, B., Blankenberg, S., Huber, K., Plebani, M., Biasucci, L. M., Tubaro, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs154 · Cited by 784
Self-citationSerial Changes in Highly Sensitive Troponin I Assay and Early Diagnosis of Myocardial Infarction
Keller, T., Zeller, T., Ojeda, F., Tzikas, S., Lillpopp, L., Sinning, C., Wild, P., Genth-Zotz, S., Warnholtz, A., Giannitsis, E., et al. (2011) · JAMA · doi:10.1001/jama.2011.1896 · Cited by 509
Self-citationFourth Universal Definition of Myocardial Infarction (2018)
Thygesen, K., Alpert, J. S., Jaffe, A. S., Chaitman, B. R., Bax, J. J., Morrow, D. A., & White, H. D. (2018) · Global Heart · doi:10.1016/j.gheart.2018.08.004 · Cited by 460
Fraser, C. G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.733 · Cited by 286
“(29) for troponin-T and used by Vasile et al.”
MethodApple, F. S., Jaffe, A. S., Collinson, P., Mockel, M., Ordonez-Llanos, J., Lindahl, B., Hollander, J., Plebani, M., Than, M., & Chan, M. H. M. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.08.021 · Cited by 286
Variability of biomarkers in patients with chronic heart failure and healthy controls
Meijers, W. C., van der Velde, A. R., Muller Kobold, A. C., Dijck-Brouwer, J., Wu, A. H., Jaffe, A., & de Boer, R. A. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.669 · Cited by 146
“Age (years), mean (SD) 43 (13) 64 (10) Male, n (%) 14 (50) 79 (95) SBP (mm Hg), mean (SD) 130 (22) 116 (17) DBP (mm Hg), mean (SD) 81 (17) 71 (11) Heart rate, mean (SD) 72 (12) 68 (10) BMI (kg/m2), mean (SD) 24 (4) 28 (4) Hypertension, n (%) – 28 (34) Hypercholesterolaemia, n (%) – 45 (54) Diabetes, n (%) – 12 (14) Cu…”
Self-citationWu, A. H. B. (2013) · Current Heart Failure Reports · doi:10.1007/s11897-013-0156-6 · Cited by 45
Self-citationTrimethylamine-N-oxide and its biological variations in vegetarians.
Obeid, R., Awwad, H. M., Keller, M., & Geisel, J. (2017) · European Journal of Nutrition · doi:10.1007/s00394-016-1295-9 · Cited by 38
Metadata
- Authors
- Frankenstein, L., Wu, A. H., Hallermayer, K., Wians, F. H., Giannitsis, E., & Katus, H. A.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-07-01
- Volume
- 57
- Issue
- 7
- Pages
- 1068-1071
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2105883854
- Cited by
- 126
- References
- 0
- FWCI
- 10.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.