CoChat

Circulating MicroRNA miR-323-3p as a Biomarker of Ectopic Pregnancy

Open access
Zhao, Zhen, Zhao, Qiuhong, Warrick, Joshua, Lockwood, Christina M, Woodworth, Alison, Moley, Kelle H, Gronowski, Ann M · 2012 · Clinical Chemistry
Cited by 100

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The use of serum human chorionic gonadotropin (hCG) and progesterone to identify patients with ectopic pregnancy (EP) has been shown to have poor clinical utility. Pregnancy-associated circulating microRNAs (miRNAs) have been proposed as potential biomarkers for the diagnosis of pregnancy-associated complications. This proof-of-concept study examined the diagnostic accuracy of various miRNAs to detect EP in an emergency department (ED) setting. METHODS: This study was a retrospective case–control analysis of 89 women who presented to the ED with vaginal bleeding and/or abdominal pain/cramping and received a diagnosis of viable intrauterine pregnancy (VIP), spontaneous abortion (SA), or EP. Serum hCG and progesterone concentrations were measured by immunoassays. The serum concentrations of miRNAs miR-323-3p, miR-517a, miR-519d, and miR-525-3p were measured with TaqMan real-time PCR. Statistical analysis was performed to determine the clinical utility of these biomarkers, both as single markers and as multimarker panels for EP. RESULTS: Concentrations of serum hCG, progesterone, miR-517a, miR-519d, and miR-525-3p were significantly lower in EP and SA cases than in VIP cases (P < 0.01). In contrast, the concentration of miR-323-3p was significantly increased in EP cases, compared with SA and VIP cases (P < 0.01). As a single marker, miR-323-3p had the highest sensitivity of 37.0% (at a fixed specificity of 90%). In comparison, the combined panel of hCG, progesterone, and miR-323-3p yielded the highest sensitivity (77.8%, at a fixed specificity of 90%). A stepwise analysis that used hCG first, added progesterone, and then added miR-323-3p yielded a 96.3% sensitivity and a 72.6% specificity. CONCLUSIONS: Pregnancy-associated miRNAs, especially miR-323-3p, added substantial diagnostic accuracy to a panel including hCG and progesterone for the diagnosis of EP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2011.179283

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Zhao, Z., Zhao, Q., Warrick, J., Lockwood, C. M., Woodworth, A., Moley, K. H., & Gronowski, A. M.
Venue
Clinical Chemistry
Published
2012-05-01
Volume
58
Issue
5
Pages
896-905
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2146543607
Cited by
100
References
3
FWCI
10.13
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.