The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Quantifying the Accuracy of a Diagnostic Test or Marker
Abstract
BACKGROUND: In recent years, increasing focus has been directed to the methodology for evaluating (new) tests or biomarkers. A key step in the evaluation of a diagnostic test is the investigation into its accuracy. CONTENT: We reviewed the literature on how to assess the accuracy of diagnostic tests. Accuracy refers to the amount of agreement between the results of the test under evaluation (index test) and the results of a reference standard or test. The generally recommended approach is to use a prospective cohort design in patients who are suspected of having the disease of interest, in which each individual undergoes the index and same reference standard tests. This approach presents several challenges, including the problems that can arise with the verification of the index test results by the preferred reference standard test, the choice of cutoff value in case of a continuous index test result, and the determination of how to translate accuracy results to recommendations for clinical use. This first in a series of 4 reports presents an overview of the designs of single-test accuracy studies and the concepts of specificity, sensitivity, posterior probabilities (i.e., predictive values) for the presence of target disease, ROC curves, and likelihood ratios, all illustrated with empirical data from a study on the diagnosis of suspected deep venous thrombosis. Limitations of the concept of the diagnostic accuracy for a single test are also highlighted. CONCLUSIONS: The prospective cohort design in patients suspected of having the disease of interest is the optimal approach to estimate the accuracy of a diagnostic test. However, the accuracy of a diagnostic index test is not constant but varies across different clinical contexts, disease spectrums, and even patient subgroups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Self-citationTowards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Self-citationEmpirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
(1975) · New England Journal of Medicine · doi:10.1056/nejm197507312930513 · Cited by 1,017
Predictive Value of a Single Diagnostic Test in Unselected Populations
Vecchio, T. J. (1966) · New England Journal of Medicine · doi:10.1056/nejm196605262742104 · Cited by 941
Reitsma, J. B., Rutjes, A. W. S., Khan, K. S., Coomarasamy, A., & Bossuyt, P. M. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.02.005 · Cited by 405
Self-citationMoons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Self-citation
Cited by
Serdar, C. C., Cihan, M., Yücel, D., & Serdar, M. A. (2021) · Biochemia medica · doi:10.11613/bm.2021.010502 · Cited by 1,570
Translation of proteomic biomarkers into FDA approved cancer diagnostics: issues and challenges
Füzéry, A. K., Levin, J., Chan, M. M., & Chan, D. W. (2013) · Clinical Proteomics · doi:10.1186/1559-0275-10-13 · Cited by 428
Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests
Bossuyt, P. M., Reitsma, J. B., Linnet, K., & Moons, K. G. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.182576 · Cited by 330
Self-citationDirect and Functional Biomarkers of Vitamin B6 Status
Ueland, P. M., Ulvik, A., Rios-Avila, L., Midttun, Ø., & Gregory, J. F. (2015) · Annual Review of Nutrition · doi:10.1146/annurev-nutr-071714-034330 · Cited by 303
DNA Methylation Biomarkers: Cancer and Beyond
Mikeska, T., & Craig, J. (2014) · Genes · doi:10.3390/genes5030821 · Cited by 288
Metadata
- Authors
- Linnet, K., Bossuyt, P. M. M., Moons, K. G. M., & Reitsma, J. B.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-09-01
- Volume
- 58
- Issue
- 9
- Pages
- 1292-1301
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2151700469
- Cited by
- 167
- References
- 8
- FWCI
- 13.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.