Genomic High-Resolution Profiling of Single CKpos/CD45neg Flow-Sorting Purified Circulating Tumor Cells from Patients with Metastatic Breast Cancer
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Circulating tumor cells (CTCs) are promising surrogate markers for systemic disease, and their molecular characterization might be relevant to guide more individualized cancer therapies. To enable fast and efficient purification of individual CTCs, we developed a work flow from CellSearchTM cartridges enabling high-resolution genomic profiling on the single-cell level. METHODS: Single CTCs were sorted from 40 CellSearch samples from patients with metastatic breast cancer using a MoFlo XDP cell sorter. Genomes of sorted single cells were amplified using an adapter–linker PCR. Amplification products were analyzed by array-based comparative genomic hybridization, a gene-specific quantitative PCR (qPCR) assay for cyclin D1 (CCND1) locus amplification, and genomic sequencing to screen for mutations in exons 1, 9, and 20 of the phosphatidylinositol-4,5-bisphosphate 3-kinase, catalytic subunit alpha (PIK3CA) gene and exons 5, 7, and 8 of the tumor protein p53 (TP53) gene. RESULTS: One common flow-sorting protocol was appropriate for 90% of the analyzed CellSearch cartridges, and the detected CTC numbers correlated positively with those originally detected with the CellSearch system (R2 = 0.9257). Whole genome amplification was successful in 72.9% of the sorted single CTCs. Over 95% of the cells displayed chromosomal aberrations typical for metastatic breast cancers, and amplifications at the CCND1 locus were validated by qPCR. Aberrant CTCs from 2 patients harbored mutations in exon 20 of the PIK3CA gene. CONCLUSIONS: This work flow enabled effective CTC isolation and provided insights into genomic alterations of CTCs in metastatic breast cancer. This approach might facilitate further molecular characterization of rare CTCs to increase understanding of their biology and as a basis for their molecular screening in the clinical setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
The patterns and dynamics of genomic instability in metastatic pancreatic cancer
Campbell, P. J., Yachida, S., Mudie, L. J., Stephens, P. J., Pleasance, E. D., Stebbings, L. A., Morsberger, L. A., Latimer, C., McLaren, S., Lin, M.-L., et al. (2010) · Nature · doi:10.1038/nature09460 · Cited by 1,317
Cited by
Clinical Applications of Circulating Tumor Cells and Circulating Tumor DNA as Liquid Biopsy
Alix-Panabières, C., & Pantel, K. (2016) · Cancer Discovery · doi:10.1158/2159-8290.cd-15-1483 · Cited by 1,394
Liquid biopsy and minimal residual disease - latest advances and implications for cure
Pantel, K., & Alix-Panabières, C. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-019-0187-3 · Cited by 1,110
Liquid Biopsies, What We Do Not Know (Yet)
Bardelli, A., & Pantel, K. (2017) · Cancer Cell · doi:10.1016/j.ccell.2017.01.002 · Cited by 482
Challenges in circulating tumor cell detection by the CellSearch system
Andree, K. C., van Dalum, G., & Terstappen, L. W. M. M. (2016) · Molecular Oncology · doi:10.1016/j.molonc.2015.12.002 · Cited by 363
Clinical applications of the CellSearch platform in cancer patients
Riethdorf, S., O'Flaherty, L., Hille, C., & Pantel, K. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.01.011 · Cited by 275
ctDNA and CTCs in Liquid Biopsy – Current Status and Where We Need to Progress
Neumann, M. H. D., Bender, S., Krahn, T., & Schlange, T. (2018) · Computational and Structural Biotechnology Journal · doi:10.1016/j.csbj.2018.05.002 · Cited by 204
“CellSearch-Flow sorting [43], CellSearch-CellCelector [44] or CellSearch-DEPArray [42].”
MethodJackson, J. M., Witek, M. A., Kamande, J. W., & Soper, S. A. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00016b · Cited by 172
Microfluidic Sample Preparation for Single Cell Analysis
Hosic, S., Murthy, S. K., & Koppes, A. N. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04077 · Cited by 166
Metadata
- Authors
- Neves, R. P. L., Raba, K., Schmidt, O., Honisch, E., Meier-Stiegen, F., Behrens, B., Möhlendick, B., Fehm, T., Neubauer, H., Klein, C. A., Polzer, B., Sproll, C., Fischer, J. C., Niederacher, D., & Stoecklein, N. H.
- Venue
- Clinical Chemistry
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-10-01
- Volume
- 60
- Issue
- 10
- Pages
- 1290-1297
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2003917867
- Cited by
- 78
- References
- 2
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.