Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 187

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Laboratory Evaluation of Pheochromocytoma and Paraganglioma

Eisenhofer, Graeme, Peitzsch, Mirko · 2014 · Clinical Chemistry

Abstract

BACKGROUND: Pheochromocytomas and paragangliomas (PPGLs) are potentially lethal yet usually surgically curable causes of endocrine hypertension; therefore, once clinical suspicion is aroused it is imperative that clinicians choose the most appropriate laboratory tests to identify the tumors. CONTENT: Compelling evidence now indicates that initial screening for PPGLs should include measurements of plasma free metanephrines or urine fractionated metanephrines. LC-MS/MS offers numerous advantages over other analytical methods and is the method of choice when measurements include methoxytyramine, the O-methylated metabolite of dopamine. The plasma test offers advantages over the urine test, although it is rarely implemented correctly, rendering the urine test preferable for mainstream use. To ensure optimum diagnostic sensitivity for the plasma test, reference intervals must be established for blood samples collected after 30 min of supine rest and after an overnight fast when measurements include methoxytyramine. Similarly collected blood samples during screening, together with use of age-adjusted reference intervals, further minimize false-positive results. Extents and patterns of increases in plasma normetanephrine, metanephrine, and methoxytyramine can additionally help predict size and adrenal vs extraadrenal locations of tumors, as well as presence of metastases and underlying germline mutations of tumor susceptibility genes. SUMMARY: Carried out correctly at specialist endocrine centers, collection of blood for measurements of plasma normetanephrine, metanephrine, and methoxytyramine not only provides high accuracy for diagnosis of PPGLs, but can also guide clinical decision-making about follow-up imaging strategies, genetic testing, and therapeutic options. At other centers, measurements of urine fractionated metanephrines will identify most PPGLs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2014.224832

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 187

Metadata

Authors
Eisenhofer, G., & Peitzsch, M.
Venue
Clinical Chemistry
Published
2014-12-01
Volume
60
Issue
12
Pages
1486-1499
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2026927104
Cited by
187
References
4
FWCI
17.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laboratory Evaluation of Pheochromocytoma and Paraganglioma. https://app.cochat.ai/papers/10.1373/clinchem.2014.224832
The paper
Eisenhofer, G., & Peitzsch, M. (2014). Laboratory Evaluation of Pheochromocytoma and Paraganglioma. Clinical Chemistry. https://doi.org/10.1373/clinchem.2014.224832

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.