Comparison of Information-Dependent Acquisition on a Tandem Quadrupole TOF vs a Triple Quadrupole Linear Ion Trap Mass Spectrometer for Broad-Spectrum Drug Screening
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Liquid chromatography high-resolution mass spectrometry (LC-HRMS) with untargeted data collection is especially attractive for general unknown drug screening owing to its ability to identify unexpected compounds. LC-HRMS offers several advantages over traditional selected reaction monitoring (SRM) techniques and could be an ideal screening platform as long as its analytical performance is comparable to that of SRM-based methods. METHODS: We developed a broad-spectrum drug screen on a high-resolution mass spectrometer [tandem quadrupole time-of-flight (QqTOF)] that collected data in an untargeted manner and compared its performance to a nominal mass instrument [triple quadrupole linear ion trap (QqLIT)] that collected data in a targeted manner. Both methods used information-dependent acquisition of product ion spectra. We evaluated the lower limits of detection and matrix effects for each method and compared their ability to identify drugs in 100 routine clinical urine samples. Additional information (patient prescription history, drug screening results, etc.) was used to confirm discordant results. RESULTS: QqLIT was slightly more analytically sensitive than QqTOF; however, this difference did not significantly affect compound identification in patient samples. QqLIT identified 596 drugs in the urine samples, of which 531 (89%) were confirmed. QqTOF identified 515 drugs, of which 500 (97%) were confirmed. There were 562 instances of a confirmed drug (68 unique drugs) in the 100 urine samples; the methods were concordant in 469 of these instances. CONCLUSIONS: Overall, QqTOF performed similarly to QqLIT and could serve as an alternative method for general unknown screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krauss, M., Singer, H., & Hollender, J. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3608-9 · Cited by 743
Cited by
Identification of small molecules using accurate mass MS/MS search
Kind, T., Tsugawa, H., Cajka, T., Ma, Y., Lai, Z., Mehta, S. S., Wohlgemuth, G., Barupal, D. K., Showalter, M. R., Arita, M., et al. (2018) · Mass Spectrometry Reviews · doi:10.1002/mas.21535 · Cited by 479
Blanckaert, P., Cannaert, A., Van Uytfanghe, K., Hulpia, F., Deconinck, E., Van Calenbergh, S., & Stove, C. (2020) · Drug Testing and Analysis · doi:10.1002/dta.2738 · Cited by 116
Multiple Fentanyl Overdoses — New Haven, Connecticut, June 23, 2016
Tomassoni, A. J., Hawk, K. F., Jubanyik, K., Nogee, D. P., Durant, T., Lynch, K. L., Patel, R., Dinh, D., Ulrich, A., & D’Onofrio, G. (2017) · MMWR. Morbidity and Mortality Weekly Report · doi:10.15585/mm6604a4 · Cited by 99
“Serum and urine specimens were later analyzed at the University of California, San Francisco (UCSF) using liquid chromatography highresolution mass spectrometry (LC-HRMS) (1) to detect 215 common illicit and pharmaceutical drugs and metabolites, followed by additional analyses in attempts to identify 7,038 novel drugs…”
MethodSelf-citationNitazene test strips: a laboratory evaluation
De Vrieze, L. M., Stove, C. P., & Vandeputte, M. M. (2024) · Harm Reduction Journal · doi:10.1186/s12954-024-01078-8 · Cited by 34
“Liquid chromatography coupled to time-of-flight mass spectrometry (LC-QTOF-MS) analysis of the powder samples was performed as previously described [47].”
MethodVandeputte, M. M., Glatfelter, G. C., Walther, D., Layle, N. K., St. Germaine, D. M., Ujváry, I., Iula, D. M., Baumann, M. H., & Stove, C. P. (2024) · Pharmacological Research · doi:10.1016/j.phrs.2024.107503 · Cited by 35
Metadata
- Authors
- Thoren, K. L., Colby, J. M., Shugarts, S. B., Wu, A. H. B., & Lynch, K. L.
- Venue
- Clinical Chemistry
- Published
- 2015-10-09
- Volume
- 62
- Issue
- 1
- Pages
- 170-178
- ISSN
- 0009-9147 (ISSN-L)
- 1530-8561
- OpenAlex
- W2264657035
- Cited by
- 84
- References
- 1
- FWCI
- 16.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.