CoChat

Multiplexed Quantification of Proglucagon-Derived Peptides by Immunoaffinity Enrichment and Tandem Mass Spectrometry after a Meal Tolerance Test

Open access
Lee, Anita Y H, Chappell, Derek L, Bak, Monika J, Judo, Michael, Liang, Linda, Churakova, Tatyana, Ayanoglu, Gulesi, Castro-Perez, Jose, Zhou, Haihong, Previs, Stephen, Souza, Sandra C, Lassman, Michael E, Laterza, Omar F · 2016 · Clinical Chemistry
Cited by 59

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Proglucagon-derived peptides (PGDPs), which include glucagon-like peptide (GLP)-1, glucagon, and oxyntomodulin, are key regulators of glucose homeostasis and satiety. These peptide hormones are typically measured with immuno-based assays (e.g., ELISA, RIA), which often suffer from issues of selectivity. METHODS: We developed a multiplexed assay for measuring PGDPs including GLP-1 (7–36) amide, GLP-1 (9–36) amide, glucagon, and oxyntomodulin by mass spectrometry and used this assay to examine the effect of a meal tolerance test on circulating concentrations of these hormones. Participants fasted overnight and were either given a meal (n = 8) or continued to fast (n = 4), with multiple blood collections over the course of 3 h. Plasma samples were analyzed by microflow immunoaffinity (IA)-LC-MS/MS with an isotope dilution strategy. RESULTS: Assay performance characteristics were examined and established during analytical validation for all peptides. Intra- and interassay imprecision were found to be 2.2%–10.7% and 6.8%–22.5%, respectively. Spike recovery was >76%, and dilution linearity was established up to a 16-fold dilution. Immediately after the meal tolerance test, GLP-1 and oxyntomodulin concentrations increased and had an almost identical temporal relationship, and glucagon concentrations increased with a slight delay. CONCLUSIONS: IA-LC-MS/MS was used for the simultaneous and selective measurement of PGDPs. This work includes the first indication of the physiological concentrations and modulation of oxyntomodulin after a meal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1373/clinchem.2015.244251

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 59

Metadata

Authors
Lee, A. Y. H., Chappell, D. L., Bak, M. J., Judo, M., Liang, L., Churakova, T., Ayanoglu, G., Castro-Perez, J., Zhou, H., Previs, S., Souza, S. C., Lassman, M. E., & Laterza, O. F.
Venue
Clinical Chemistry
Published
2016-01-01
Volume
62
Issue
1
Pages
227-235
ISSN
  • 0009-9147 (ISSN-L)
  • 1530-8561
OpenAlex
W2178413308
Cited by
59
References
4
FWCI
2.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplexed Quantification of Proglucagon-Derived Peptides by Immunoaffinity Enrichment and Tandem Mass Spectrometry after a Meal Tolerance Test. https://app.cochat.ai/papers/10.1373/clinchem.2015.244251
The paper
Lee, A. Y. H., Chappell, D. L., Bak, M. J., Judo, M., Liang, L., Churakova, T., Ayanoglu, G., Castro-Perez, J., Zhou, H., Previs, S., Souza, S. C., Lassman, M. E., & Laterza, O. F. (2016). Multiplexed Quantification of Proglucagon-Derived Peptides by Immunoaffinity Enrichment and Tandem Mass Spectrometry after a Meal Tolerance Test. Clinical Chemistry. https://doi.org/10.1373/clinchem.2015.244251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.