CoChat

Exhaled Air Dispersion Distances During Noninvasive Ventilation via Different Respironics Face Masks

Open access
Hui, David S., Chow, Benny K., Ng, Susanna S., Chu, Leo C.Y., Hall, Stephen D., Gin, Tony, Sung, Joseph J.Y., Chan, Matthew T.V. · 2009 · Chest
Cited by 141

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background As part of our influenza pandemic preparedness, we studied the exhaled air dispersion distances and directions through two different face masks (Respironics; Murrysville, PA) attached to a human-patient simulator (HPS) during noninvasive positive-pressure ventilation (NPPV) in an isolation room with pressure of −5 Pa. Methods The HPS was positioned at 45° on the bed and programmed to mimic mild lung injury (oxygen consumption, 300 mL/min; lung compliance, 35 mL/cm H2O). Airflow was marked with intrapulmonary smoke for visualization. Inspiratory positive airway pressure (IPAP) started at 10 cm H2O and gradually increased to 18 cm H2O, whereas expiratory pressure was maintained at 4 cm H2O. A leakage jet plume was revealed by a laser light sheet, and images were captured by high definition video. Normalized exhaled air concentration in the plume was estimated from the light scattered by the smoke particles. Findings As IPAP increased from 10 to 18 cm H2O, the exhaled air of a low normalized concentration through the ComfortFull 2 mask (Respironics) increased from 0.65 to 0.85 m at a direction perpendicular to the head of the HPS along the median sagittal plane. When the IPAP of 10 cm H2O was applied via the Image 3 mask (Respironics) connected to the whisper swivel, the exhaled air dispersed to 0.95 m toward the end of the bed along the median sagittal plane, whereas higher IPAP resulted in wider spread of a higher concentration of smoke. Conclusions Substantial exposure to exhaled air occurs within a 1-m region, from patients receiving NPPV via the ComfortFull 2 mask and the Image 3 mask, with more diffuse leakage from the latter, especially at higher IPAP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1378/chest.09-0434

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 24

  1. Yuen, 1998, Clinical features and rapid viral diagnosis of human disease associated with avian influenza A H5N1 virus, Lancet, 351, 467, 10.1016/S0140-6736(98)01182-9 · DOI · Paper page
  2. Arabi, 2007, The critically ill avian influenza A (H5N1) patient, Crit Care Med, 35, 1397, 10.1097/01.CCM.0000262940.34596.4B · DOI
  3. Hui, 2008, Review of clinical symptoms and spectrum in humans with influenza A/H5N1 infection, Respirology, 13, S10, 10.1111/j.1440-1843.2008.01247.x · DOI
  4. Hui, 2008, Influenza A/H5N1 infection: other treatment options and issues, Respirology, 13, S22, 10.1111/j.1440-1843.2008.01250.x · DOI
  5. Hui, 2006, Non-invasive positive pressure ventilation: an experimental model to assess air and particle dispersion, Chest, 130, 730, 10.1378/chest.130.3.730 · DOI
  6. Lee, 2003, A major outbreak of severe acute respiratory syndrome in Hong Kong, N Engl J Med, 348, 1986, 10.1056/NEJMoa030685 · DOI · Paper page
  7. Hui, 2006, Airflows around oxygen masks: a potential source of infection?, Chest, 130, 822, 10.1378/chest.130.3.822 · DOI
  8. Hui, 2007, Exhaled air dispersion during oxygen delivery via a simple oxygen mask, Chest, 132, 540, 10.1378/chest.07-0636 · DOI
  9. Hui, 2009, Exhaled air and aerosolized droplet dispersion during application of a jet nebulizer, Chest, 135, 648, 10.1378/chest.08-1998 · DOI
  10. Kuhlen, 2003, Breathing pattern and workload during automatic tube compensation, pressure support and T-piece trials in weaning patients, Eur J Anaesthesiol, 20, 10, 10.1097/00003643-200301000-00002 · doi:10.1097/00003643-200301000-00002
  11. Light, 1999, Pulmonary pathophysiology of pneumococcal pneumonia, Semin Respir Infect, 14, 218
  12. Good, 2003, Patient simulation for training basic and advanced clinical skills, Med Educ, 37, 14, 10.1046/j.1365-2923.37.s1.6.x · DOI · Paper page
  13. Meka, 2004, Bellows-less lung system for the human patient simulator, Med Biol Eng Comput, 42, 413, 10.1007/BF02344718 · doi:10.1007/bf02344718
  14. So, 2004, Performance of an oxygen delivery device for weaning potentially infectious critically ill patients, Anaesthesia, 59, 710, 10.1111/j.1365-2044.2004.03802.x · doi:10.1111/j.1365-2044.2004.03802.x
  15. Goodwin, 2004, A model for educational simulation of infant cardiovascular physiology, Anesth Analg, 99, 1655, 10.1213/01.ANE.0000134797.52793.AF · doi:10.1213/01.ane.0000134797.52793.af
  16. Lampotang, 2006, An audible indication of exhalation increases delivered tidal volume during bag valve mask ventilation of a patient simulator, Anesth Analg, 102, 168, 10.1213/01.ANE.0000181833.23904.4E · doi:10.1213/01.ane.0000181833.23904.4e
  17. Ambrosino, 2008, Noninvasive positive pressure ventilation in the acute care setting: where are we?, Eur Respir J, 31, 874, 10.1183/09031936.00143507 · DOI · Paper page
  18. Tang, 2006, Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises, J Hosp Infect, 64, 100, 10.1016/j.jhin.2006.05.022 · DOI · Paper page
  19. Tran, 2004, Avian influenza A (H5N1) in 10 patients in Vietnam, N Engl J Med, 350, 1179, 10.1056/NEJMoa040419 · DOI · Paper page
  20. Han, 2004, Noninvasive positive pressure ventilation treatment for acute respiratory failure in SARS, Sleep Breath, 8, 97, 10.1055/s-2004-829634 · doi:10.1055/s-2004-829634
  21. Cheung, 2004, Effectiveness of noninvasive positive pressure ventilation in the treatment of acute respiratory failure in severe acute respiratory syndrome, Chest, 126, 845, 10.1378/chest.126.3.845 · DOI · Paper page
  22. Yu, 2007, Why did outbreaks of severe acute respiratory syndrome occur in some hospital wards but not in others?, Clin Infect Dis, 44, 1017, 10.1086/512819 · DOI · Paper page
  23. Li, 2007, Role of ventilation in airborne transmission of infectious agents in the built environment: a multidisciplinary systematic review, Indoor Air, 17, 2, 10.1111/j.1600-0668.2006.00445.x · DOI · Paper page
  24. Wong, 2004, Index patient and SARS outbreak in Hong Kong, Emerg Infect Dis, 10, 339, 10.3201/eid1002.030645 · DOI

Cited by

See all 141

Metadata

Authors
Hui, D. S., Chow, B. K., Ng, S. S., Chu, L. C. Y., Hall, S. D., Gin, T., Sung, J. J. Y., & Chan, M. T. V.
Venue
Chest
Publisher
Elsevier BV
Published
2009-10
Volume
136
Issue
4
Pages
998-1005
ISSN
0012-3692 (ISSN-L)
OpenAlex
W2049786759
Cited by
141
References
3
FWCI
4.07
Type
journal article
Language
en
Open access
bronze
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.