Reliability of Pulse Oximetry in Titrating Supplemental Oxygen Therapy in Ventilator-Dependent Patients
Abstract
Pulse oximetry is widely used in the critical care setting, but few studies have examined its usefulness in clinical decision making. One area where pulse oximetry might be useful is in the titration of fractional inspired O2 concentration (FIO2) in ventilator-dependent patients. Unfortunately, documented guidelines for this use do not exist, and in a survey of directors of intensive care units, we found that they employed a wide range of target O2 saturation (SpO2) values. Consequently, we undertook a study to determine if SpO2 could be reliably substituted for measurements of arterial O2 tension (PaO2) when adjusting FIO2 in ventilator-dependent patients. We examined a number of SpO2 target values in 54 critically ill patients aiming for a PaO2 of greater than or equal to 60 mm Hg, while minimizing the risk of O2 toxicity. In white patients, we found that a SpO2 target of 92 percent was reliable in predicting a satisfactory level of oxygenation. However, in black patients, such a SpO2 reading was commonly associated with significant hypoxemia (PaO2 as low as 49 mm Hg), and a higher SpO2 target, 95 percent, was required. In addition, inaccurate oximetry readings (ie, greater than 4 percent difference between SpO2 and direct SaO2 measurements) were more common in black (27 percent) than in white patients (11 percent, p less than 0.05). In conclusion, a SpO2 target of 92 percent was reliable when titrating supplemental O2 in white patients receiving mechanical ventilation; however, in black patients, such a SpO2 reading was commonly associated with significant hypoxemia, and a higher SpO2 target, 95 percent, was required to ensure a satisfactory level of oxygenation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A study about applying a pulse oximeter device in the titration of fractional inspired O2 concentration in ventilator-dependent patients revealed that a SpO2 reading of 92% was reliable when titrating supplemental O2 in light-skinned patients receiving mechanical ventilation. However, in dark-skinned patients, the same SpO2 value was commonly related to significant hypoxemia, and a higher SpO2”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [88]
In the citing paper
“A study performed in 1990 in ventilator-dependent patients when titrating supplemental O2 report inaccurate measurements in dark-skinned patients [88].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [88]
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Continuous or Nocturnal Oxygen Therapy in Hypoxemic Chronic Obstructive Lung Disease
NOCTURNAL OXYGEN THERAPY TRIAL GROUP (1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-3-391 · Cited by 2,202
Harrison's Principles of Internal Medicine
Bigby, J. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670020093028 · Cited by 1,249
Yelderman, M., & New, W. (1983) · Anesthesiology · doi:10.1097/00000542-198310000-00015 · Cited by 488
Tremper, K. K., & Barker, S. J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00019 · Cited by 453
Complications of Percutaneous Radial-artery Cannulation: An Objective Prospective Study in Man
Bedford, R. F., & Wollman, H. (1973) · Anesthesiology · doi:10.1097/00000542-197303000-00006 · Cited by 293
Respiratory Monitoring in the Intensive Care Unit
Tobin, M. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1625 · Cited by 200
Self-citationADULT RESPIRATORY DISTRESS SYNDROME
Kollef, M. H. (1996) · Southern Medical Journal · doi:10.1097/00007611-199604000-00024 · Cited by 199
History of blood gas analysis.
Jw, S., & Astrup, P. (1987) · PubMed · Cited by 187
The Effect of Nail Polish on Pulse Oximetry
COT, C. J., Goldstein, E. A., Fuchsman, W. H., & Hoaglin, D. C. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198807000-00013 · Cited by 171
Flagged first, then by citations
Research works printed but not linked: 1
- Berlin, 1988, Pulse oximetry: a technology that needs direction, Respir Care, 33, 243
Cited by
Sorted by citations
Items 201–291 of 291
Bilan, N., Dastranji, A., & Behbahani, A. (2014) · Journal of medical research/The journal of medical research · Cited by 2
Noninvasive Respiratory Monitoring
Jubran, A., & Tobin, M. J. (2008) · Elsevier eBooks · doi:10.1016/b978-032304841-5.50015-7 · Cited by 2
Self-citationVentilation and Pulmonary Function
Cereda, M. F., & Neligan, P. J. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4377-0167-8.00020-0 · Cited by 2
Measuring Tissue Oxygen Saturation via Spectrometer in Children
Goldman, R. D., Aziz, A. S., Marques, L., & Rogovik, A. L. (2010) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181a5b332 · Cited by 2
Chronic Obstructive Pulmonary Disease
Domínguez‐Cherit, G., Posadas-Calleja, J. G., & Borunda, D. (2008) · Elsevier eBooks · doi:10.1016/b978-032304841-5.50042-x · Cited by 2
Evaluating the effect of skin color on photoplethysmography signals in a vascular finger phantom
Osorio-Sanchez, L., May, J. M., & Kyriacou, P. (2026) · Design and Quality for Biomedical Technologies · doi:10.1117/12.3079657 · Cited by 1
Sanderson, J., & Albon, L. (2026) · BMJ Case Reports · doi:10.1136/bcr-2025-271307 · Cited by 1
The Association of Skin Pigmentation With Pulse Oximetry Bias in Adult Patients in the ICU
Yang, P., Felzer, J., Tovar, S., ten Lohuis, C., Bender, W., Johnson, D. A., Haardöerfer, R., Valley, T. S., Wong, A.-K. I., & Bhavani, S. V. (2026) · CHEST Critical Care · doi:10.1016/j.chstcc.2026.100277 · Cited by 1
Chen, Q.-C., Shen, J., Huang, Y.-L., Kong, R., Xie, Y.-M., & Wang, S. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e28336 · Cited by 1
Aeromedical Transport of the Mechanically Ventilated Patient
Wachtel, A., Allen, H. N., & Lewis, M. I. (1997) · Journal of Intensive Care Medicine · doi:10.1177/088506669701200604 · Cited by 1
Bilan, N., Dastranji, A., & Behbahan, A. G. (2015) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 1
Increased Inspiratory Oxygen Fractions (FIO2) Using a Conventional Drug Delivery Nebuliser
Gea, J., Orozco‐Levi, M., & Gallart, L. (2010) · Archivos de Bronconeumología · doi:10.1016/s1579-2129(10)70058-6 · Cited by 1
Ventilación mecánica en paciente con enfermedad pulmonar obstructiva crónica
Figueroa, R. S., & Hernández, F. A. (2012) · Cited by 1
Hypoxemia and oxygen saturation by pulse oximeter
Kanai, R., Uzawa, K., Moriyama, K., Kotani, M., Kohyama, T., Nakazawa, H., Yasuda, H., & Yorozu, T. (2014) · Journal of the Japanese Society of Intensive Care Medicine · doi:10.3918/jsicm.21.175 · Cited by 1
Unreliable pulse oximetry in dark-skin patients: a plea for algorithm disclosure
Tobin, M. J., & Jubran, A. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-00993-y · Cited by 1
Self-citationPannu, S. R., Haddad, T. C., Exline, M. C., Christman, J. W., Horowitz, J. C., Peters, J., Brock, G. N., Diaz, P., & Crouser, E. D. (2022) · Contemporary Clinical Trials · doi:10.1016/j.cct.2022.106811 · Cited by 1
Fu, L.-X., Yu, H., Lan, L., Luo, F.-M., & Ni, Y.-N. (2023) · Heart & Lung · doi:10.1016/j.hrtlng.2023.01.001 · Cited by 1
Swamy, S. K. N., He, C., Liu, C., Correia, R. G., Hayes‐Gill, B., Clark, D. J., Green, S., & Morgan, S. P. (2024) · Design and Quality for Biomedical Technologies · doi:10.1117/12.3000705 · Cited by 1
Wilkie, P. Y., Namdar, K., Samsel, K., Pasricha, S. V., Jaiswal, N., Salo, Z., So, M., Panchal, S., Malhotra, A. K., Nashnoush, E., et al. (2025) · FACETS · doi:10.1139/facets-2025-0117 · Cited by 1
Protocol to assess performance of crisis standards of care guidelines for clinical triage
Merriam, L. T., Bharadwaj, M. C., Jezmir, J. L., Leaf, D. E., & Kim, E. Y. (2021) · STAR Protocols · doi:10.1016/j.xpro.2021.100943 · Cited by 1
Severinghaus, J. W. (1992) · Springer eBooks · doi:10.1007/978-4-431-68201-1_126 · Cited by 1
Pulse Oximetry Con: Stop Living in the Cave
Winters, B. D., & Sarwal, A. (2023) · Critical Care Medicine · doi:10.1097/ccm.0000000000005892 · Cited by 1
SHOULD OXYGEN SATURATION BE INCLUDED IN THE VITAL SIGNS SHEET OF ALL MEDICAL ADMISSIONS?
Al-Mobeireek, A., Abba, A., & Kumo, A. (2002) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2002.tb11224.x · Cited by 1
Monitoring and Assessment of the Pulmonary Function in Ventilated Infants and Children
Sivan, Y., & Newth, C. J. L. (1996) · Update in intensive care and emergency medicine · doi:10.1007/978-3-642-80227-0_35 · Cited by 1
Critical Care: A System-Oriented Approach
Cobb, J. P. (2001) · Springer eBooks · doi:10.1007/978-3-642-57282-1_16 · Cited by 1
Fawzy, A., & Wise, R. A. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202309-754ed · Cited by 1
Verkruysse, W., Rogowitz, B. E., Milkes, D. H., Mannheimer, P. D., Kopotic, R. J., & Monk, E. P. (2025) · Research Square · doi:10.21203/rs.3.rs-7112852/v1 · Cited by 1
Pulse oximetry in people with darker skin tones
Valley, T. S., & Fogarty, A. (2026) · BMJ · doi:10.1136/bmj.s37 · Cited by 1
Oxygen therapy management for patients at risk of respiratory dysfunction
Eastwood, G. M. (2012)
Management of Asthma in the Emergency Room Setting
Canny, G. J. (1997) · KARGER eBooks · doi:10.1159/000061886
Monitorización perioperatoria del oxígeno y del dióxido de carbono
Tassaux, D., & Clergue, F. (2003) · EMC - Anestesia-Reanimación · doi:10.1016/s1280-4703(03)71830-1
Monitoring during mechanical ventilation
HESS, D. R. (2006) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2006.04.177
Définitions et fiabilité des paramètres monitorés: surveillance des gaz du sang
Jarreau, P. H., Fougère, S., & Bourgain, J. L. (2000) · Réanimation Urgences · doi:10.1016/s1164-6756(00)90020-3
Juvé, J. I., Roca, J. V., & Puigdevall, J. M. R. (2004) · Elsevier eBooks · doi:10.1016/b978-84-8174-708-9.50017-7
Krachman, S. L., & Tobin, M. J. (2002) · Elsevier eBooks · doi:10.1016/b978-012079028-9/50133-2
Self-citationPeroxisome proliferator-activated receptor ligands for airway diseases?
Parameswaran, K. (2003) · Thorax · doi:10.1136/thorax.58.6.542
Monitoring during Mechnical Ventilation
Hess, D. (1996) · Canadian Respiratory Journal · doi:10.1155/1996/494865
Special critical care tools and techniques
de Velde, M. V., Scholefield, H. J., & Plante, L. A. (2013) · Cambridge University Press eBooks · doi:10.1017/cbo9781139088084.018
Bedside Pulse Oximeters with a Clinical Algorithm Make Economic Sense in the Intensive Care Unit
Leasa, D. J., & Walker, J. M. (1996) · Canadian Respiratory Journal · doi:10.1155/1996/783141
Alarm level for SpO2: differences between SpO2 and SaO2
Seo, K. (2014) · Journal of the Japanese Society of Intensive Care Medicine · doi:10.3918/jsicm.21.130
(2010) · CRC Press eBooks · doi:10.1201/b13434-34
HOW ACCURATE IS THE PULSE OXIMETRY READING IN AN INTENSIVE CARE SETUP
Srivatsan, R., Asmathulla, S., & Girija, S. (2015) · International Journal of Pharma and Bio Sciences
Krachman, S. L., & Tobin, M. J. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374001-4.00057-2
Self-citationMarino, P. L. (2017) · Elsevier eBooks · doi:10.1016/b978-3-437-23162-9.00021-4
Gnahoré, G. T., Kelly, J. L., O’Riordan, S. L., Bolger, F. B., Doran, M. M., Sands, M., & Lowry, J. P. (2020) · Analytical Methods · doi:10.1039/d0ay00206b
F IO 2 : An Inspired Solution for a Universal Problem
Sampson, C. M., Khan, M. N., & Kinsky, M. P. (2021) · Respiratory Care · doi:10.4187/respcare.09552
Demiselle, J., Calzia, E., Hartmann, C., Messerer, D. A. C., Asfar, P., Radermacher, P., & Datzmann, T. (2021) · Kompass Neumología · doi:10.1159/000519761
[Polikarp Girsztowt--surgery professor at the Warsaw Szkoła Główna].
Stocki, E. (1978) · PubMed
A Simplified Approach to Covid-19 Disease in Adult Patients for General Practitioners
Sabry, E. Y. (2020) · International Journal of Respiratory and Pulmonary Medicine · doi:10.23937/2378-3516/1410143
Non-invasive mechanical ventilation
Elliott, M. (2008) · Medicine · doi:10.1016/j.mpmed.2008.02.007
Giani, M., & Bellani, G. (2019) · doi:10.1183/9781849841221.029118
Terzano, C., & Pacilio, R. (2008) · Springer eBooks · doi:10.1007/978-88-470-0467-2_32
What Decoloniality Looks Like in the Health Market
Bruce, F., & Clennon, O. D. (2022) · Springer eBooks · doi:10.1007/978-3-031-18405-5_2
Тимрук-Скоропад, К. А. (2018) · Health sport rehabilitation · doi:10.34142/hsr.2018.04.03.14
Fogarty, A., Crooks, C. J., Adejumo, I., Binegdie, A. B., & Shaw, D. E. (2023) · Journal of the Pan African Thoracic Society · doi:10.25259/jpats_22_2023
Comment on Yang and Moss Commentary
Iwashyna, T. J., Ferryman, K. S., Drabo, E. F., Jackson, J. W., & Crews, D. C. (2023) · CHEST Journal · doi:10.1016/j.chest.2023.07.4224
Eriş, E., Mammadova, A., Kara, A. T., Atasoy, A., Solmaz, Z. S., & Gürsel, G. (2024) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2024.2840
Pulse Oximetry: A Vital Tool with Important Functional Limitations for Patients with Dark Skin Color
Harris, D. E. (2024) · Universal Library of Clinical Nursing · doi:10.70315/uloap.ulcnu.2024.0101005
Pannu, S. R., Peters, J., Zimmer, J., Brock, G. N., Exline, M. C., Horowitz, J. C., Thompson, B., Rice, T. W., & Crouser, E. D. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-094924 · Cited by 1
Lellouche, F. (2025) · Respiratory Care · doi:10.1177/19433654251380224
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495940
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495958
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495979
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495961
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495955
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495967
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495964
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495943
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495988
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495982
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495970
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495949
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495973
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495976
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495946
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495937
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495991
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495985
Shi, C., Goodall, M., Dumville, J. C., Hill, J. E., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.20495994
Mitigating Skin Pigmentation Bias in Pulse Oximetry through Personalized Machine Learning Models
Ostrowski, C. D., Karli, H. B., & Unluturk, B. D. (2025) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi67747.2025.11269488
Delgado, M., Fritze, R., Hilty, M. P., Krauthammer, M., Schuepbach, R. A., Ganter, C. C., & Bartussek, J. (2026) · Antioxidants · doi:10.3390/antiox15020235
Pilot Study: Using Reflectance as a Proxy for Skin Pigmentation to Assess Pulse Oximeter Accuracy
Branstad, A., Buttar, S., Kabir, R., Byrapuneni, S., Eid, M., Sandozi, A., BELTRAND, E., Evans, M. D., Joy, B. F., Goertzen, L., et al. (2026) · Hospital Pediatrics · doi:10.1542/hpeds.2025-008471
Pandey, B., Jha, B., Shahi, S., & Adhikari, S. (2026) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000004747
Ghane, M., Elmore, M., Dankwa‐Mullan, I., Stapleton, S., Owens, K., Khalid, S., Delonay, A., Youssef, A., Chisunka, M., Rariy, C., et al. (2026) · The American Journal of Bioethics · doi:10.1080/15265161.2026.2677391
Osorio-Sanchez, L., May, J. M., & Kyriacou, P. A. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-39674-7_17
Making the Shift from Student to Learner
Rooseboom, T., Smith, P., Striker, N., MacKinnon, S. L., & Drew, R. (2026) · doi:10.32393/mssl
Zhang, Y., Gao, L., Zhu, W., Chen, W., Liu, Y., Chen, H., 王艳玲, Li, Y., Huang, F., Tang, J., et al. (2026) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-026-01500-5
Occult hypoxemia in the ICU: Clinical risk factors, mortality and implications for nursing practice
Caillet, A., Vacheron, C., Dargent, A., & Allaouchiche, B. (2026) · Intensive and Critical Care Nursing · doi:10.1016/j.iccn.2026.104594
Effects of Skin Pigmentation on Pulse Oximetry: A Pilot Study
Cotton, S. A., Dahdoul, T., Best, N. C., Guo, Y., Lee, J.-A., Malhotra, A., & McGuire, W. C. (2026) · American Journal of Critical Care · doi:10.4037/ajcc2026253
Metadata
- Authors
- Jubran, A., & Tobin, M. J.
- Affiliations
- The University of Texas Health Science Center at Houston (US)
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 1990-06
- Volume
- 97
- Issue
- 6
- Pages
- 1420-1425
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W1996518979
- Cited by
- 296
- References
- 22
- Citations by year
- 2026: 16 · 2025: 18 · 2024: 25 · 2023: 29 · 2022: 54 · 2021: 11 · 2020: 8 · 2019: 4 · 2018: 4 · 2017: 3 · 2016: 5 · 2015: 5 · 2014: 13 · 2013: 4 · 2012: 6
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- CHEST Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- pulse oximetry, supplemental oxygen, mechanical ventilation, arterial oxygen tension, hypoxemia, racial differences, arterial oxygen saturation, oxygen toxicity, critically ill patients
- MeSH terms
- Algorithms, Black or African American, Female, Humans, Intensive Care Units, Male, Middle Aged, Oximetry, Oxygen, Oxygen Inhalation Therapy, Partial Pressure, Ventilators, Mechanical, White People
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review