Reliability of Pulse Oximetry in Titrating Supplemental Oxygen Therapy in Ventilator-Dependent Patients
Abstract
Pulse oximetry is widely used in the critical care setting, but few studies have examined its usefulness in clinical decision making. One area where pulse oximetry might be useful is in the titration of fractional inspired O2 concentration (FIO2) in ventilator-dependent patients. Unfortunately, documented guidelines for this use do not exist, and in a survey of directors of intensive care units, we found that they employed a wide range of target O2 saturation (SpO2) values. Consequently, we undertook a study to determine if SpO2 could be reliably substituted for measurements of arterial O2 tension (PaO2) when adjusting FIO2 in ventilator-dependent patients. We examined a number of SpO2 target values in 54 critically ill patients aiming for a PaO2 of greater than or equal to 60 mm Hg, while minimizing the risk of O2 toxicity. In white patients, we found that a SpO2 target of 92 percent was reliable in predicting a satisfactory level of oxygenation. However, in black patients, such a SpO2 reading was commonly associated with significant hypoxemia (PaO2 as low as 49 mm Hg), and a higher SpO2 target, 95 percent, was required. In addition, inaccurate oximetry readings (ie, greater than 4 percent difference between SpO2 and direct SaO2 measurements) were more common in black (27 percent) than in white patients (11 percent, p less than 0.05). In conclusion, a SpO2 target of 92 percent was reliable when titrating supplemental O2 in white patients receiving mechanical ventilation; however, in black patients, such a SpO2 reading was commonly associated with significant hypoxemia, and a higher SpO2 target, 95 percent, was required to ensure a satisfactory level of oxygenation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A study about applying a pulse oximeter device in the titration of fractional inspired O2 concentration in ventilator-dependent patients revealed that a SpO2 reading of 92% was reliable when titrating supplemental O2 in light-skinned patients receiving mechanical ventilation. However, in dark-skinned patients, the same SpO2 value was commonly related to significant hypoxemia, and a higher SpO2”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [88]
In the citing paper
“A study performed in 1990 in ventilator-dependent patients when titrating supplemental O2 report inaccurate measurements in dark-skinned patients [88].”
From Skin pigmentation influence on pulse oximetry accuracy: a systematic review and bibliometric analysis (2022) · cites this paper as [88]
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Continuous or Nocturnal Oxygen Therapy in Hypoxemic Chronic Obstructive Lung Disease
NOCTURNAL OXYGEN THERAPY TRIAL GROUP (1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-3-391 · Cited by 2,202
Harrison's Principles of Internal Medicine
Bigby, J. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670020093028 · Cited by 1,249
Yelderman, M., & New, W. (1983) · Anesthesiology · doi:10.1097/00000542-198310000-00015 · Cited by 488
Tremper, K. K., & Barker, S. J. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00019 · Cited by 453
Complications of Percutaneous Radial-artery Cannulation: An Objective Prospective Study in Man
Bedford, R. F., & Wollman, H. (1973) · Anesthesiology · doi:10.1097/00000542-197303000-00006 · Cited by 293
Respiratory Monitoring in the Intensive Care Unit
Tobin, M. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1625 · Cited by 200
Self-citationADULT RESPIRATORY DISTRESS SYNDROME
Kollef, M. H. (1996) · Southern Medical Journal · doi:10.1097/00007611-199604000-00024 · Cited by 199
History of blood gas analysis.
Jw, S., & Astrup, P. (1987) · PubMed · Cited by 187
The Effect of Nail Polish on Pulse Oximetry
COT, C. J., Goldstein, E. A., Fuchsman, W. H., & Hoaglin, D. C. (1988) · Anesthesia & Analgesia · doi:10.1213/00000539-198807000-00013 · Cited by 171
Research works printed but not linked: 1
- Berlin, 1988, Pulse oximetry: a technology that needs direction, Respir Care, 33, 243
Cited by
Sorted by citations
Items 101–200 of 291
Burns, P., Driessen, B., Boston, R., & Gunther, R. A. (2006) · Veterinary Anaesthesia and Analgesia · doi:10.1111/j.1467-2995.2005.00271.x · Cited by 16
Nguyen, L. S., Helias, M., Raia, L., Nicolas, E., Jaubert, P., Benghanem, S., Hamou, Z. A., Dupland, P., Charpentier, J., Pène, F., et al. (2022) · Scientific Reports · doi:10.1038/s41598-021-02634-z · Cited by 15
Yang, K., González, D., Woodhead, J. L., Bhargava, P., & Ramanathan, M. K. (2025) · Clinical and Translational Science · doi:10.1111/cts.70272 · Cited by 16
Ashraf, H., Alam, N. H., Chisti, M. J., Salam, M. A., Ahmed, T., & Gyr, N. E. (2012) · BMJ Open · doi:10.1136/bmjopen-2012-000961 · Cited by 15
Thomas, F. O., Hoffman, T. L., Handrahan, D. L., Crapo, R. O., & Snow, G. L. (2009) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181a5f055 · Cited by 15
Garnet, B., Lankenau, R. D., Jean, E., & Campos, M. (2023) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202209-837oc · Cited by 15
Effect of measurement errors on cardiac output calculated with O2 and modified CO2 Fick methods
Mahutte, C. K., & Jaffe, M. B. (1995) · The Journal of Clinical Monitoring · doi:10.1007/bf01617731 · Cited by 14
Pulse Oximeter Bias and Inequities in Retrospective Studies––Now What?
Moore, K., Gudelunas, K., Lipnick, M. S., Bickler, P. E., & Hendrickson, C. M. (2022) · Respiratory Care · doi:10.4187/respcare.10654 · Cited by 14
Interpretation of Oxygen Saturation in Congenital Heart Disease: Fact and Fallacy
Olsen, J., & Puri, K. (2022) · Pediatrics in Review · doi:10.1542/pir.2020-005364 · Cited by 13
Pulse Oximetry: 2023 Year in Review
HESS, D. R. (2024) · Respiratory Care · doi:10.4187/respcare.12023 · Cited by 13
Kalra, A., Wilcox, C. J., Holmes, S. D., Tonna, J. E., Jeong, I. S., Rycus, P. T., Anders, M. M., Zaaqoq, A. M., Lorusso, R., Brodie, D., et al. (2024) · Lung · doi:10.1007/s00408-024-00711-4 · Cited by 13
Eskaros, S. M., Papadakos, P. J., & Lachmann, B. (2010) · Elsevier eBooks · doi:10.1016/b978-0-443-06959-8.00044-3 · Cited by 13
More on Racial Bias in Pulse Oximetry Measurement
Sjoding, M. W., Iwashyna, T. J., & Valley, T. S. (2021) · New England Journal of Medicine · doi:10.1056/nejmc2101321 · Cited by 13
Haxha, S., Nwibor, C., Ali, M., Sakel, M., Saunders, K., Dyo, V., & Nabakooza, S. (2024) · Sensors · doi:10.3390/s24113301 · Cited by 12
The Big Consequences of Small Discrepancies: Why Racial Differences in Pulse Oximetry Errors Matter
Holder, A. L., & Wong, A.-K. I. (2022) · Critical Care Medicine · doi:10.1097/ccm.0000000000005447 · Cited by 13
Disparities among patients with respiratory failure
Blank, J. A., Armstrong-Hough, M., & Valley, T. S. (2023) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000001079 · Cited by 13
Usual and Advanced Monitoring in Patients Receiving Oxygen Therapy
Lellouche, F., & L’Her, E. (2020) · Respiratory Care · doi:10.4187/respcare.07623 · Cited by 12
Kalra, A., Shou, B. L., Zhao, D. X., Wilcox, C. J., Keller, S. P., Whitman, G. J. R., Kim, B. S., Cho, S., Calligy, K., Brown, P., et al. (2023) · JTCVS Open · doi:10.1016/j.xjon.2023.02.011 · Cited by 12
Tucker, S., Edmonds, S. W., Cullen, L., Hanrahan, K., & Laures, E. L. (2023) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2023.07.002 · Cited by 12
Assessment of skin pigmentation-related bias in pulse oximetry readings among adults
Khanna, A. K., Beard, J., Lamminmäki, S., Närväinen, J., Antaki, N., & Yapici, H. O. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01095-1 · Cited by 12
Abe, T., Takagi, T., & Fujii, T. (2023) · Critical Care · doi:10.1186/s13054-023-04370-4 · Cited by 12
Cruz, S., Lu, C., Ulloa, M., Redding, A., Hester, J. D., & Jacobs, M. L. (2024) · JMIR mhealth and uhealth · doi:10.2196/50826 · Cited by 11
Hemodynamic Assessment and Monitoring in the Intensive Care Unit: an Overview
Adler, A. C., Sharma, R., Higgins, T. J. V., & McGee, W. T. (2014) · Enliven Journal of Anesthesiology and Critical Care Medicine · doi:10.18650/2374-4448.14010 · Cited by 11
Detection and monitoring of Hypoxemia and Oxygen Therapy
HESS, D. R. (2000) · Respiratory Care · doi:10.1177/002013240004500106 · Cited by 11
Pulse Oximetry Discrepancies and Occult Hypoxemia in ICU Patients: Predictors and Clinical Outcomes
Saidy, S. O., Iqbal, A., & Baig, S. H. (2025) · Journal of Intensive Care Medicine · doi:10.1177/08850666251351594 · Cited by 10
Adams, A. T., Mandel, I., Gao, Y., Heckman, B. W., Nandakumar, R., & Choudhury, T. (2022) · JMIR Biomedical Engineering · doi:10.2196/34934 · Cited by 10
The Role of Data Science in Closing the Implementation Gap
King, A. J., & Kahn, J. M. (2023) · Critical Care Clinics · doi:10.1016/j.ccc.2023.03.005 · Cited by 10
Adult Highlights From the Extracorporeal Life Support Organization Registry: 2017–2022
Rali, A. S., Abbasi, A. A., Alexander, P. M. A., Anders, M. M., Arachchillage, D. J., Barbaro, R. P., Fox, A. D., Friedman, M. L., Malfertheiner, M. V., Ramanathan, K. R., et al. (2023) · ASAIO Journal · doi:10.1097/mat.0000000000002038 · Cited by 10
Treatment of Childhood Pneumonia in Developing Countries
Ashraf, H., Jobayer, M., & Haque, N. M. S. (2010) · Sciyo eBooks · doi:10.5772/9887 · Cited by 10
Erol, S., Kaya, A. G., Çiftçi, F., Çiledağ, A., Şen, E., Kaya, A., Çelik, G., & Savaş, İ. (2016) · The Clinical Respiratory Journal · doi:10.1111/crj.12591 · Cited by 10
Pottecher, J., BOUZOU, G., & DELOUW, A. (2003) · Réanimation · doi:10.1016/s1624-0693(02)00006-3 · Cited by 10
Ethical Imagination: Broadening Laboratory Deliberations
van der Burg, S. (2010) · The International library of ethics, law and technology · doi:10.1007/978-90-481-8647-1_9 · Cited by 9
Inaccuracy of pulse oximetry in darker-skinned patients is unchanged across 32 years
Tobin, M. J., & Jubran, A. (2022) · European Respiratory Journal · doi:10.1183/13993003.00520-2022 · Cited by 9
Self-citationDiscrimination by Design: Is It Time to Recalibrate Interpretation of Pulse Oximetry?*
Barreto, J. A., & Moynihan, K. M. (2023) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000003229 · Cited by 8
Vianna, J. R. D. F., Lorenzo, V. A. P. D., Simões, M. M. L. D. S., & Jamami, M. (2016) · Respiratory Care · doi:10.4187/respcare.04665 · Cited by 8
Overt and Occult Hypoxemia in Patients Hospitalized With COVID-19
Gadrey, S. M., Mohanty, P., Haughey, S. P., Jacobsen, B. A., Dubester, K. J., Webb, K. M., Kowalski, R. L., Dreicer, J. J., Andris, R. T., Clark, M., et al. (2023) · Critical Care Explorations · doi:10.1097/cce.0000000000000825 · Cited by 8
Diagnostic Measures to Evaluate Oxygenation in Critically Ill Adults
Johnson, K. L. (2004) · AACN Clinical Issues Advanced Practice in Acute & Critical Care · doi:10.1097/00044067-200410000-00003 · Cited by 8
Noninvasive Respiratory Monitoring During Ventilatory Support
HESS, D. R. (1991) · Critical Care Nursing Clinics of North America · doi:10.1016/s0899-5885(18)30683-x · Cited by 8
Lellouche, F., & Branson, R. D. (2024) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202401-0243vp · Cited by 7
Evaluation of a Pulse Oximeter Sensor Tester
Dugani, S., Hodzovic, I., Sindhakar, S., Nadra, A., Dunstan, C., Wilkes, A. R., & Mecklenburgh, J. S. (2011) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9283-3 · Cited by 7
Li, M., Norton, J. A., Bollinger, R. R., Chang, A. E., Lowry, S. F., Mulvihill, S. J., Pass, H. I., & Thompson, R. W. (2003) · Springer eBooks · doi:10.1007/b98876 · Cited by 7
Mador, M. J., & Tobin, M. J. (1995) · Springer eBooks · doi:10.1007/978-1-4899-4525-9_19 · Cited by 7
Self-citationHESS, D. R., & Medoff, B. D. (1999) · Current Opinion in Critical Care · doi:10.1097/00075198-199902000-00008 · Cited by 7
Prehospital pulse oximetry: Useful or misused?
Cydulka, R. K., Shade, B., Emerman, C. L., Gersham, H., & Kubincanek, J. (1992) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)82778-7 · Cited by 7
Plaisime, M. V. (2023) · American Journal of Epidemiology · doi:10.1093/aje/kwad019 · Cited by 8
Cotton, S. A., Lee, J.-A., Malhotra, A., & McGuire, W. C. (2025) · Clinical Nursing Research · doi:10.1177/10547738251374746 · Cited by 6
McGuire, W. C., Pearce, A. K., Elliott, A. R., Fine, J. M., West, J. B., Crouch, D. R., Prisk, G. K., & Malhotra, A. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12196203 · Cited by 6
Pulse oximeter bench tests under different simulated skin tones
Swamy, S. K. N., He, C., Hayes‐Gill, B., Clark, D. J., Green, S., & Morgan, S. P. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03091-2 · Cited by 6
de Matos, J. C. R. G., Alwakeel, M. I., Hao, S., Naamani, D., Struja, T., Gichoya, J. W., Celi, L. A., McMahon, T., King, H. A., Cox, C. E., et al. (2025) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202406-1242oc · Cited by 6
Efficiency of goal-directed oxygen delivery in ICU patients
Jochmans, S., Vong, L. V., Rolin, N., Sy, O., Chelly, J., Ellrodt, O., Alphonsine, J.-E., Serbource‐Goguel, J., Abdallah, R. I., Weyer, C.-M., et al. (2016) · Anaesthesiology Intensive Therapy · doi:10.5603/ait.a2016.0027 · Cited by 6
Daubin, C., Haddad, L., Folscheid, D., Boyer, A., Chalumeau-Lemoine, L., Guisset, O., Hubert, P., Pillot, J., Robert, R., & Dreyfuss, D. (2014) · Annals of Intensive Care · doi:10.1186/2110-5820-4-23 · Cited by 6
Home oxygen monitoring and therapy: learning from the pandemic
Beaney, T. E., & Clarke, J. (2022) · Current Opinion in Critical Care · doi:10.1097/mcc.0000000000001010 · Cited by 7
Using S pO 2 : Not as Simple as It Seems
HESS, D. R. (2023) · Respiratory Care · doi:10.4187/respcare.10955 · Cited by 6
Marley, R. A. (1998) · Journal of PeriAnesthesia Nursing · doi:10.1016/s1089-9472(98)80010-5 · Cited by 6
Wong, J. K. L., Thomas, C., Gravett, H., Thobhani, K., Mekhaimar, A., Wong, J. M., & Wan, Y. I. (2025) · BJA Open · doi:10.1016/j.bjao.2025.100425 · Cited by 6
Diagnosis and Management of Overlap Syndrome (COPD-OSA): Evidence, Challenges and Prospects
Wei, X., Zhang, X., Wang, S., Tong, X., Wu, C., Hu, S., & Shi, L. (2026) · Nature and Science of Sleep · doi:10.2147/nss.s560579 · Cited by 5
Basing intubation of acutely hypoxemic patients on physiologic principles
Laghi, F. A., Shaikh, H., & Caccani, N. (2024) · Annals of Intensive Care · doi:10.1186/s13613-024-01327-w · Cited by 5
Approach to acute respiratory failure for frontline clinicians
See, K. C. (2022) · Singapore Medical Journal · doi:10.4103/singaporemedj.smj-2022-002 · Cited by 5
Effect of newborn screening for critical CHD on healthcare utilisation
Bizmark, R. S., Kumamaru, H., Webber, E. J., Estevez, D., Mena, L. A., Marr, E. H., & Chang, R. R. (2020) · Cardiology in the Young · doi:10.1017/s1047951120001742 · Cited by 5
Bedside Monitoring of Pulmonary Function
Gentile, M. A., & Davies, J. D. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1367-1.00043-4 · Cited by 5
Monitoring Gas Exchange: Clinical Effectiveness and Cost Considerations
Durbin, C. G. (1994) · Respiratory Care · doi:10.1177/194336549403900205 · Cited by 5
What Should the Clinician Do When a Patient "Fights the Ventilator"?
Tobin, M. J. (1991) · Respiratory Care · doi:10.1177/194336549103600507 · Cited by 5
Self-citationFingertip oxygen sensors can fail on dark skin — now a physician is suing
Oza, A. (2024) · Nature · doi:10.1038/d41586-024-00089-6 · Cited by 5
Techniques and Devices for Monitoring Oxygenation
Hess, D., & Kacmarek, R. M. (1993) · Respiratory Care · doi:10.1177/194336549303800607 · Cited by 5
Clinical Implementation of Automated Oxygen Titration in a Tertiary Care Hospital
Bouchard, P.-A., Parent-Racine, G., Paradis-Gagnon, C., Simon, M., Lacasse, Y., Lellouche, F., & Maltais, F. (2024) · Respiratory Care · doi:10.4187/respcare.11331 · Cited by 4
Accuracy of pulse oximetry in comparison with arterial blood gas
Elhossieny, K. M. (2020) · Research and Opinion in Anesthesia and Intensive Care · doi:10.4103/roaic.roaic_91_18 · Cited by 4
Pannu, S. R., Exline, M. C., Klamer, B. G., Brock, G. N., Crouser, E. D., Christman, J. W., & Diaz, P. (2022) · Critical Care Explorations · doi:10.1097/cce.0000000000000704 · Cited by 4
Pulse Oximetry: A Necessary Imperfect Tool in Critical Care
Athale, J., & Suffredini, A. F. (2023) · Critical Care Medicine · doi:10.1097/ccm.0000000000005891 · Cited by 4
Short: Racial Disparities in Pulse Oximetry Cannot Be Fixed With Race-Based Correction
Patwari, N., Huang, D., & Bonetta-Misteli, F. (2023) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1145/3580252.3586986 · Cited by 4
Takagi, T., Fujii, T., Nakamura, S., Tsutsumi, Y., & Uezono, S. (2025) · CHEST Journal · doi:10.1016/j.chest.2025.03.006 · Cited by 4
Hypoxemia in trauma patients receiving two different oxygen strategies: a TRAUMOX2 substudy
Rosenkrantz, O., Arleth, T., Creutzburg, A., Petersen, L. B., Bækgaard, J. S., Zwisler, S. T., Mikkelsen, S. S., Klimek, M., Rasmussen, L. S., & Steinmetz, J. (2025) · Scandinavian Journal of Trauma Resuscitation and Emergency Medicine · doi:10.1186/s13049-025-01360-z · Cited by 4
Belenguer-Muncharaz, A., Andrés, E. B., Valero, R. R., Font, S., Tusón, R. C., & Campos, R. A. (2001) · Medicina Intensiva · doi:10.1016/s0210-5691(01)79718-5 · Cited by 4
(1991) · Respiratory Care · doi:10.1177/194336549103601210 · Cited by 4
Conventional Oxygen Therapy: Technical and Physiological Issues
Lellouche, F., & L’Her, E. (2021) · Springer eBooks · doi:10.1007/978-3-030-42454-1_1 · Cited by 3
Role and Use of Race in Artificial Intelligence and Machine Learning Models Related to Health
Were, M. C., Li, A., Malin, B., Yin, Z., Coco, J., Collins, B. X., Clayton, E. W., Novak, L. L., Hendricks‐Sturrup, R., Oluyomi, A., et al. (2025) · Journal of Medical Internet Research · doi:10.2196/73996 · Cited by 4
Crooks, C. J., West, J., Morling, J. R., Simmonds, M., Juurlink, I., Briggs, S., Cruickshank, S., Hammond-Pears, S., Shaw, D. E., Card, T. R., et al. (2024) · European Respiratory Journal · doi:10.1183/13993003.02320-2023 · Cited by 3
Racial Disparities in Pulse Oximetry, in COVID-19 and ICU Settings
Reep, C. A. T., Fleuren, L. M., Heunks, L. M. A., & Wils, E. (2024) · Critical Care Explorations · doi:10.1097/cce.0000000000001132 · Cited by 3
Brytanova, T. S., Малецький, М. М., Лисянська, Г. П., & Antypenko, L. (2022) · Journal of Pharmaceutical Health Services Research · doi:10.1093/jphsr/rmac007 · Cited by 3
Marlar, A. I., Knabe, B. K., Taghikhan, Y., Applegate, R. L., & Fleming, N. (2024) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-024-01211-9 · Cited by 3
Gea, J., Orozco‐Levi, M., & Gallart, L. (2010) · Archivos de Bronconeumología · doi:10.1016/j.arbres.2010.02.002 · Cited by 3
Avant, M. G., Lowe, N., & Torres, A. (1997) · Respiratory Care · doi:10.1177/002013249704200705 · Cited by 3
Effects of Zero PEEP and < 1.0 F IO 2 on S pO 2 and P ETCO 2 During Open Endotracheal Suctioning
Vianna, J. R. D. F., Lorenzo, V. A. P. D., Simões, M. M. L. D. S., Guerra, J. L., & Jamami, M. (2020) · Respiratory Care · doi:10.4187/respcare.07435 · Cited by 3
Non-invasive mechanical ventilation
Elliott, M. (2004) · Medicine · doi:10.1383/medc.32.1.99.28469 · Cited by 3
Critical Care: A System-Oriented Approach
Cobb, J. P. (2006) · Springer eBooks · doi:10.1007/0-387-22744-x_10 · Cited by 3
Ruppel, H., Huang, L., Petit, C. J., Qureshi, A. M., Bonafide, C. P., Foglia, E. E., Feldman, J., Lane-Fall, M. B., Lynch, J. M., Chien, A. L.-L., et al. (2025) · BMJ Open · doi:10.1136/bmjopen-2025-100391 · Cited by 2
Sharma, M., Brown, A. W., Chung, S., Sexton, K. W., Schootman, M., & Mourani, P. M. (2025) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2025.114720 · Cited by 2
Validity of two subjective skin tone scales and its implications on healthcare model fairness
Cu, C. W., Dundas, N. E., Heintz, T., Sheikh, Z. A., Alonso-Bermudez, B., Walker, J., Wooten, A., Badathala, A., Chapman, A., Ehie, O. A., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01975-7 · Cited by 3
Salutogenomics: embracing the full spectrum of human health
Collins, N., Heyborne, G., Fuentes, A., Lund, J. R., & Ilardo, M. A. (2026) · Trends in Genetics · doi:10.1016/j.tig.2025.12.004 · Cited by 2
Kittredge Lecture: Pulse Oximetry Facts and Fallacies
Lipnick, M. S. (2026) · Respiratory Care · doi:10.1177/19433654251412742 · Cited by 2
Hendrickson, C. M., Lipnick, M. S., Chen, D., Chen, D., Law, T. J., Pirracchio, R., Feiner, J., Behnke, E., Chou, Y., Elmankabadi, S., et al. (2026) · CHEST Critical Care · doi:10.1016/j.chstcc.2026.100305 · Cited by 2
Confronting Racism in Pulmonology
Hachey, K., & Smith, J. P. (2022) · Annals of the American Thoracic Society · doi:10.1513/annalsats.202209-800ip · Cited by 2
Abe, T., Takagi, T., & Fujii, T. (2023) · Annual update in intensive care and emergency medicine · doi:10.1007/978-3-031-23005-9_13 · Cited by 2
Limitations in the Use of Pulse Oximetry in Patients of Color
Pal, A. D. (2023) · Journal of PeriAnesthesia Nursing · doi:10.1016/j.jopan.2023.08.018 · Cited by 2
Addressing Racial Disparities in Pulse Oximetry: A Machine Learning Perspective
Karli, H. B., & Unluturk, B. D. (2024) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/ieeeconf60004.2024.10943105 · Cited by 2
Racial Differences in Accuracy of Predictive Models for High-Flow Nasal Cannula Failure in COVID-19
Yang, P., Gregory, I. A., Robichaux, C. J., Holder, A. L., Martin, G. S., Esper, A. M., Kamaleswaran, R., Gichoya, J. W., & Bhavani, S. V. (2024) · Critical Care Explorations · doi:10.1097/cce.0000000000001059 · Cited by 2
Cavagnoli, A., & Taglietti, M. (2014) · Fiep Bulletin - online · Cited by 2
Diniz, G. D. C. L. M., Zin, W. A., Botoni, F. A., de Castro, A. V., & Rodrigues‐Machado, M. D. G. (2009) · Revista Brasileira de Terapia Intensiva · doi:10.1590/s0103-507x2009000300009 · Cited by 2
van der Burg, S. (2010) · Innovation The European Journal of Social Science Research · doi:10.1080/13511611003791158 · Cited by 2
Monitoring the critically ill gravida
Gordon, E. K. B., Plante, L. A., & Deutschman, C. S. (2013) · Cambridge University Press eBooks · doi:10.1017/cbo9781139088084.022 · Cited by 2
Metadata
- Authors
- Jubran, A., & Tobin, M. J.
- Affiliations
- The University of Texas Health Science Center at Houston (US)
- Venue
- Chest
- Publisher
- Elsevier BV
- Published
- 1990-06
- Volume
- 97
- Issue
- 6
- Pages
- 1420-1425
- ISSN
- 0012-3692 (ISSN-L)
- OpenAlex
- W1996518979
- Cited by
- 296
- References
- 22
- Citations by year
- 2026: 16 · 2025: 18 · 2024: 25 · 2023: 29 · 2022: 54 · 2021: 11 · 2020: 8 · 2019: 4 · 2018: 4 · 2017: 3 · 2016: 5 · 2015: 5 · 2014: 13 · 2013: 4 · 2012: 6
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- CHEST Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- pulse oximetry, supplemental oxygen, mechanical ventilation, arterial oxygen tension, hypoxemia, racial differences, arterial oxygen saturation, oxygen toxicity, critically ill patients
- MeSH terms
- Algorithms, Black or African American, Female, Humans, Intensive Care Units, Male, Middle Aged, Oximetry, Oxygen, Oxygen Inhalation Therapy, Partial Pressure, Ventilators, Mechanical, White People
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review