Clinical utilization of shear wave elastography in the musculoskeletal system
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Ultrasonography (renamed from the Journal of Korean Society of Ultrasound in Medicine in January 2014), the official English-language journal of the Korean Society of Ultrasound in Medicine (KSUM), is an international peer-reviewed academic journal dedicated to practice, research, technology, and education dealing with medical ultrasound, Aims and Scope:Ultrasonography (renamed from the Journal of Korean Society of Ultrasound in Medicine in January 2014), the official English-language journal of the Korean Society of Ultrasound in Medicine (KSUM), is an international peer-reviewed academic journal dedicated to practice, research, technology, and education dealing with medical ultrasound.It is published four times per year: January 1, April 1, July 1, and October 1. Original articles, topical reviews, pictorial essays, and notable case reports are published in Ultrasonography covering state-of-the-art content. Ultrasonography also serves as a medium for cooperation among physicians and specialists from around the world who are focusing on various ultrasound technology and disease problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gennisson, J.-L., Deffieux, T., Macé, E., Montaldo, G., Fink, M., & Tanter, M. (2010) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2010.02.013 · Cited by 683 · cited 1×
“Shear waves propagate more readily along muscle fibers when the transducer is oriented longitudinally, rather than perpendicular or at a 45° oblique angle [29,30] to the tendon, and SWE measurements obtained parallel to the muscle fibers increase, as expected, with increasing tensile load [29].”
BackgroundValidation of shear wave elastography in skeletal muscle
Eby, S. F., Song, P., Chen, S., Chen, Q., Greenleaf, J. F., & An, K.-N. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.033 · Cited by 545 · cited 1×
“Shear waves propagate more readily along muscle fibers when the transducer is oriented longitudinally, rather than perpendicular or at a 45° oblique angle [29,30] to the tendon, and SWE measurements obtained parallel to the muscle fibers increase, as expected, with increasing tensile load [29].”
BackgroundShear wave elastography for breast masses is highly reproducible
the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C. (2012) · European Radiology · doi:10.1007/s00330-011-2340-y · Cited by 406 · cited 1×
“While previous studies have demonstrated excellent inter-reader repeatability in the skin [5], and almost perfect inter-reader repeatability in the breast [6] and liver [7], results in the musculoskeletal system have been much more varied.”
BackgroundMaïsetti, O., Hug, F., Bouillard, K., & Nordez, A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.009 · Cited by 263 · cited 1×
“6) for the gastrocnemius [8-10], tibialis anterior [11], and supraspinatus [12,13] muscles and for the flexor pollicis longus [14], quadriceps [14], patellar [15], and intramuscular supraspinatus [12] tendons, it was only reported as fair to moderate (0.”
BackgroundCurrent status of musculoskeletal application of shear wave elastography
Ryu, J., & Jeong, W. K. (2017) · Ultrasonography · doi:10.14366/usg.16053 · Cited by 197 · cited 4×
“With this relationship, unless the tissue density is 1 g/mm(3), the SWS does not correspond exactly with the Young modulus [3].”
BackgroundMethodInfluentialYoshitake, Y., Takai, Y., Kanehisa, H., & Shinohara, M. (2014) · Muscle & Nerve · doi:10.1002/mus.24104 · Cited by 196
Aubry, S., Nueffer, J.-P., Tanter, M., Becce, F., Vidal, C., & Michel, F. (2015) · Radiology · doi:10.1148/radiol.14140434 · Cited by 187
Rosskopf, A. B., Ehrmann, C., Buck, F. M., Gerber, C., Flück, M., & Pfirrmann, C. W. A. (2016) · Radiology · doi:10.1148/radiol.2015150908 · Cited by 159
Koo, T. K. K., Guo, J., Cohen, J. H., & Parker, K. J. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.11.009 · Cited by 157 · cited 1×
“6) for the gastrocnemius [8-10], tibialis anterior [11], and supraspinatus [12,13] muscles and for the flexor pollicis longus [14], quadriceps [14], patellar [15], and intramuscular supraspinatus [12] tendons, it was only reported as fair to moderate (0.”
BackgroundAteş, F., Hug, F., Bouillard, K., Jubeau, M., Frappart, T., Couade, M., Bercoff, J., & Nordez, A. (2015) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2015.02.005 · Cited by 155
Alfuraih, A. M., O’Connor, P., Hensor, E. M. A., Tan, A. L., Emery, P., & Wakefield, R. J. (2017) · Journal of Clinical Ultrasound · doi:10.1002/jcu.22534 · Cited by 150 · cited 1×
“An in vivo study [25] demonstrated that the average SWS in the vastus lateralis muscle did not change with imaging depth within the muscle, although the variance within the ROI increased as depth increased.”
BackgroundDubois, G. J. R., Kheireddine, W., Vergari, C., Bonneau, D., Thoreux, P., Rouch, P., Tanter, M., Gennisson, J., & Wafa Skalli, E. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.04.020 · Cited by 150
Principles and clinical application of ultrasound elastography for diffuse liver disease
Jeong, W. K., Lim, H. K., Lee, H.-K., Jo, J. M., & Kim, Y. (2014) · ULTRASONOGRAPHY · doi:10.14366/usg.14003 · Cited by 137 · cited 1×
“Theoretically, the shear modulus, or tissue elasticity, can then be calculated from the shear wave speed (SWS), providing important biomechanical information about tissue quality [4].”
BackgroundTaş, S., Onur, M. R., YILMAZ, S., et al. (2017) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.16.03032 · Cited by 127
Nordez, A., Gennisson, J., Casari, P., Catheline, S., & Cornu, C. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.03.033 · Cited by 124 · cited 1×
“Most SWE studies have been performed on passive muscles and tendons, but some studies have focused on changes in SWS measurements with muscle activation and have demonstrated a linear relationship between increasing SWS measurements and progressive isometric contraction of the biceps brachii, suggesting that SWE is a…”
BackgroundReduced Patellar Tendon Elasticity with Aging: In Vivo Assessment by Shear Wave Elastography
Hsiao, M., Chen, Y.-C., Lin, C.-Y., Chen, W., & Wang, T. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.07.008 · Cited by 100 · cited 1×
“6) for the gastrocnemius [8-10], tibialis anterior [11], and supraspinatus [12,13] muscles and for the flexor pollicis longus [14], quadriceps [14], patellar [15], and intramuscular supraspinatus [12] tendons, it was only reported as fair to moderate (0.”
BackgroundDetermination of Normal Hepatic Elasticity by Using Real-time Shear-wave Elastography
Suh, C. H., Kim, S. Y., Kim, K. W., Lim, Y., Lee, S., Lee, M.-G., Lee, J.-B., Lee, S., & Yu, E. (2014) · Radiology · doi:10.1148/radiol.14131251 · Cited by 100
Length and activation dependent variations in muscle shear wave speed
Slane, L. C., DeWall, R. J., Lee, K. S., & Thelen, D. G. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/6/713 · Cited by 98 · cited 2×
“While differences in SWS measurements have been observed between active and passive muscles, the exact relationship remains unclear [8,24].”
BackgroundShearWave elastography: repeatability for measurement of tendon stiffness
Peltz, C. D., Haladik, J. A., Divine, G., Siegal, D. S., van Holsbeeck, M., & Bey, M. J. (2013) · Skeletal Radiology · doi:10.1007/s00256-013-1629-0 · Cited by 78 · cited 3×
“6) for the abdominal wall muscles [16] and the Achilles [14] and patellar tendons [14].”
BackgroundInfluentialSelf-citationSiu, W. L., Chan, C.-H., Lam, C.-H., Lee, C.-M., & Ying, M. T. C. (2016) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2016.02.013 · Cited by 73 · cited 1×
“[20] reported the ICC (1, k) and ICC (2, k) values, while all other studies reported ICC (1,1) and ICC (2,1) values.”
MacDonald, D. A., Wan, A., McPhee, M. E., Tucker, K. J., & Hug, F. (2015) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2015.12.002 · Cited by 72 · cited 1×
“6) for the abdominal wall muscles [16] and the Achilles [14] and patellar tendons [14].”
BackgroundHuman Patellar Tendon Strain: A Noninvasive, In Vivo Study
Sheehan, F. T., & DRACE, J. E. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200001000-00019 · Cited by 68 · cited 1×
“The same study also documented fairly static strain in the patellar tendon from 30° to 50° flexion, which is an important detail to remember when studying this tendon [36].”
BackgroundBaumer, T. G., Davis, L. C., Dischler, J., Siegal, D. S., van Holsbeeck, M., Moutzouros, V., & Bey, M. J. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.01.008 · Cited by 66 · cited 5×
“6) for the medial gastrocnemius [10], rectus femoris [21], and supraspinatus [12] muscles and the patellar [21] and intramuscular supraspinatus [12] tendons.”
BackgroundInfluentialSelf-citationEffects of age and pathology on shear wave speed of the human rotator cuff
Baumer, T. G., Dischler, J., Davis, L. C., Labyed, Y., Siegal, D. S., van Holsbeeck, M., Moutzouros, V., & Bey, M. J. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23641 · Cited by 49 · cited 2×
“While differences in SWS measurements have been observed between active and passive muscles, the exact relationship remains unclear [8,24].”
BackgroundSelf-citationYavuz, A., Bora, A., Bulut, M., Batur, A., Milanlıoğlu, A., Göya, C., & Andıç, Ç. (2015) · Medical Ultrasonography · doi:10.11152/mu.2013.2066.171.yvz · Cited by 34 · cited 2×
“Most SWE studies have been performed on passive muscles and tendons, but some studies have focused on changes in SWS measurements with muscle activation and have demonstrated a linear relationship between increasing SWS measurements and progressive isometric contraction of the biceps brachii, suggesting that SWE is a…”
BackgroundNakamura, M., Ikezoe, T., Umegaki, H., Kobayashi, T., Nishisita, S., & Ichihashi, N. (2016) · Acta Radiologica Open · doi:10.1177/2058460115604009 · Cited by 32 · cited 3×
“90 m/sec, a SWS that has been observed in passive muscle [10,12,13].”
Background
Cited by
Deep learning in ultrasound elastography imaging: A review
Li, H., Bhatt, M., Qu, Z., Zhang, S., Hartel, M. C., Khademhosseini, A., & Cloutier, G. (2022) · Medical Physics · doi:10.1002/mp.15856 · Cited by 47
Metadata
- Authors
- Davis, L. C., Baumer, T. G., Bey, M. J., & Holsbeeck, M. V.
- Venue
- Ultrasonography
- Published
- 2019-01-01
- Volume
- 38
- Issue
- 1
- Pages
- 2-12
- ISSN
- 2288-5919 (ISSN-L)
- 2288-5943
- OpenAlex
- W2888691826
- Cited by
- 169
- References
- 26
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.