The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Pulse Oximetry for Monitoring Patients with COVID-19 at Home. Potential Pitfalls and Practical Guidance
Open accessAbstract
During the ongoing coronavirus disease (COVID-19) pandemic, reports in social media and the lay press indicate that a subset of patients are presenting with severe hypoxemia in the absence of dyspnea, a problem unofficially referred to as “silent hypoxemia.” To decrease the risk of complications in such patients, one proposed solution has been to have those diagnosed with COVID-19 but not sick enough to warrant admission monitor their arterial oxygenation by pulse oximetry at home and present for care when they show evidence of hypoxemia. Though the ease of use and low cost of pulse oximetry makes this an attractive option for identifying problems at an early stage, there are important considerations with pulse oximetry about which patients and providers may not be aware that can interfere with successful implementation of such monitoring programs. Only a few independent studies have examined the performance of pocket oximeters and smart phone–based systems, but the limited available data raise questions about their accuracy, particularly as saturation falls below 90%. There are also multiple sources of error in pulse oximetry that must be accounted for, including rapid fluctuations in measurements when the arterial oxygen pressure/tension falls on the steep portion of the dissociation curve, data acquisition problems when pulsatile blood flow is diminished, accuracy in the setting of severe hypoxemia, dyshemoglobinemias, and other problems. Recognition of these issues and careful counseling of patients about the proper means for measuring their oxygen saturation and when to seek assistance can help ensure successful implementation of needed monitoring programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gandhi, R. T., Lynch, J. B., & del Rio, C. (2020) · New England Journal of Medicine · doi:10.1056/nejmcp2009249 · Cited by 1,307
Clinical Features of 85 Fatal Cases of COVID-19 from Wuhan. A Retrospective Observational Study
Du, Y., Tu, L., Zhu, P., Mu, M., Wang, R., Yang, P., Wang, X., Hu, C., Ping, R., Hu, P., et al. (2020) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.202003-0543oc · Cited by 942
Pulse oximetry: Principles and limitations
Sinex, J. E. (1999) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(99)90019-0 · Cited by 481
Effects of skin pigmentation on pulse oximeter accuracy at low saturation
Bickler, P. E., Feiner, J. R., & Severinghaus, J. W. (2005) · Anesthesiology · doi:10.1097/00000542-200504000-00004 · Cited by 427
Feiner, J. R., Severinghaus, J. W., & Bickler, P. E. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000285988.35174.d9 · Cited by 400
Regional Distribution of Pulmonary Ventilation and Perfusion in Obesity *
Holley, H. S., Milic-Emili, J., Becklake, M. R., & Bates, D. V. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105549 · Cited by 273
Errors in 14 pulse oximeters during profound hypoxia
Severinghaus, J. W., Naifeh, K. H., & Koh, S. O. (1989) · Journal of Clinical Monitoring · doi:10.1007/bf01617877 · Cited by 217
Schnapp, L. M., & Cohen, N. H. (1990) · Chest · doi:10.1378/chest.98.5.1244 · Cited by 193
Shah, S. A., Velardo, C., Farmer, A., & Tarassenko, L. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.7207 · Cited by 172
Pulse Oximetry at High Altitude
Luks, A. M., & Swenson, E. R. (2011) · High Altitude Medicine & Biology · doi:10.1089/ham.2011.0013 · Cited by 120
Self-citation
Cited by
Nalbandian, A., Sehgal, K., Gupta, A., Madhavan, M. V., McGroder, C., Stevens, J. S., Cook, J. R., Nordvig, A. S., Shalev, D., Sehrawat, T. S., et al. (2021) · Nature Medicine · doi:10.1038/s41591-021-01283-z · Cited by 4,862
Recent Advancements in Emerging Technologies for Healthcare Management Systems: A Survey
Junaid, S. B., Imam, A. A., Balogun, A. O., De Silva, L. C., Surakat, Y. A., Kumar, G., Abdulkarim, M., Shuaibu, A. N., Garba, A., Sahalu, Y., et al. (2022) · Healthcare · doi:10.3390/healthcare10101940 · Cited by 353
Review of multimodal machine learning approaches in healthcare
Krones, F., Marikkar, U., Parsons, G., Szmul, A., & Mahdi, A. (2025) · Information Fusion · doi:10.1016/j.inffus.2024.102690 · Cited by 235
Vindrola-Padros, C., Singh, K. E., Sidhu, M. S., Georghiou, T., Sherlaw-Johnson, C., Tomini, S. M., Inada-Kim, M., Kirkham, K., Streetly, A., Cohen, N., et al. (2021) · eClinicalMedicine · doi:10.1016/j.eclinm.2021.100965 · Cited by 160
Shi, C., Goodall, M., Dumville, J., Hill, J., Norman, G., Hamer, O., Clegg, A., Watkins, C. L., Georgiou, G., Hodkinson, A., et al. (2022) · doi:10.1101/2022.02.16.22271062 · Cited by 158
“The reporting of possible bias in pulse oximetry measurement, including due to skin pigmentation, raised a growing concern about the accuracy of oxygen self-monitoring.[5] Measurement bias could have serious clinical implications including the delay of urgent medical care.”
Background
Metadata
- Authors
- Luks, A. M., & Swenson, E. R.
- Venue
- Annals of the American Thoracic Society
- Publisher
- Oxford University Press (OUP)
- Published
- 2020-09-01
- Volume
- 17
- Issue
- 9
- Pages
- 1040-1046
- ISSN
- 2325-6621 (ISSN-L)
- 2329-6933
- OpenAlex
- W3033446455
- Cited by
- 263
- References
- 25
- FWCI
- 14.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse Oximetry for Monitoring Patients with COVID-19 at Home. Potential Pitfalls and Practical Guidance. https://app.cochat.ai/papers/10.1513/annalsats.202005-418fr
- The paper
- Luks, A. M., & Swenson, E. R. (2020). Pulse Oximetry for Monitoring Patients with COVID-19 at Home. Potential Pitfalls and Practical Guidance. Annals of the American Thoracic Society. https://doi.org/10.1513/annalsats.202005-418fr
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.