CoChat

Medical device alarms

Borowski, Matthias, Görges, Matthias, Fried, Roland, Such, Olaf, Wrede, Christian, Imhoff, Michael · 2011 · Biomedizinische Technik/Biomedical Engineering
Cited by 110

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The high number of false positive alarms has long been known to be a serious problem in critical care medicine - yet it remains unresolved. At the same time, threats to patient safety due to missing or suppressed alarms are being reported. The purpose of this paper is to present results from a workshop titled "Too many alarms? Too few alarms?" organized by the Section Patient Monitoring and the Workgroup Alarms of the German Association of Biomedical Engineering of the Association for Electrical, Electronic and Information Technologies. The current situation regarding alarms and their problems in intensive care, such as lack of clinical relevance, alarm fatigue, workload increases due to clinically irrelevant alarms, usability problems in alarm systems, problems with manuals and training, and missing alarms due to operator error are outlined, followed by a discussion of solutions and strategies to improve the current situation. Finally, the need for more research and development, focusing on signal quality considerations, networking of medical devices at the bedside, diagnostic alarms and predictive warnings, usability of alarm systems, education of healthcare providers, creation of annotated clinical databases for testing, standardization efforts, and patient monitoring in the regular ward, are called for.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/bmt.2011.005

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 110

Metadata

Authors
Borowski, M., Görges, M., Fried, R., Such, O., Wrede, C., & Imhoff, M.
Venue
Biomedizinische Technik/Biomedical Engineering
Published
2011-01-01
Volume
56
Issue
2
Pages
73-83
ISSN
  • 0013-5585 (ISSN-L)
  • 1862-278X
OpenAlex
W2024683287
Cited by
110
References
4
FWCI
8.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medical device alarms. https://app.cochat.ai/papers/10.1515/bmt.2011.005
The paper
Borowski, M., Görges, M., Fried, R., Such, O., Wrede, C., & Imhoff, M. (2011). Medical device alarms. Biomedizinische Technik/Biomedical Engineering. https://doi.org/10.1515/bmt.2011.005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.