The order of draw: myth or science?
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: The potential for cross-contamination of additives among evacuated blood tubes has led to the development of the order of draw. This practice, however, is mainly based on scarce, anecdotal, and mostly outdated literature data. Therefore, the goal of this investigation was to definitely establish whether or not the indication of a specific order of draw is still justified. Methods: The study population consisted of 57 outpatients referred to the outpatient oral anticoagulant (OA) clinic of the Academic Hospital of Verona and 58 healthy volunteers enrolled from the laboratory personnel. In OA outpatients, one serum tube was collected immediately after needle insertion, followed by a buffered sodium citrate tube and another serum tube. In the healthy volunteers, one serum tube was collected immediately after needle insertion, followed by a potassium-ethylenediaminetetraacetic acid (K 2-EDTA) tube and another serum tube. After separation, the serum was tested for potassium, sodium, calcium, magnesium, and phosphorus in the first and second serum tubes. Results: No significant difference could be observed between the first and the second serum tubes for any of the parameters. The bias calculated with Bland-Altman plots did not achieve statistical significance when the serum tube was collected after either a K 2-EDTA or a sodium citrate tube. Conclusions: According to our data, revision of national and supranational recommendations on blood collection by venipuncture should consider that the order of draw exerts a negligible effect on sample quality, and this aspect should no longer be considered a quality criterion when evaluating the performance of phlebotomists.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66 · cited 1×
“The order of draw has frequently been considered an important quality indicator in evaluating phlebotomy practice [18].”
BackgroundSelf-citationIncorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33
Self-citationAvoidance to wipe alcohol before venipuncture is not a source of spurious hemolysis
Salvagno, G. L., Danese, E., Lima-Oliveira, G., Guidi, G. C., & Lippi, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.023 · Cited by 20
Self-citation
Cited by
Interferences from blood collection tube components on clinical chemistry assays
Bowen, R. A. R., & Remaley, A. T. (2014) · Biochemia Medica · doi:10.11613/bm.2014.006 · Cited by 316
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationPhlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
“tube order does not affect the blood testing (109,110).”
Cornes, M., van Dongen-Lases, E., Grankvist, K., Ibarz, M., Kristensen, G., Lippi, G., Nybo, M., & Simundic, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0426 · Cited by 92
Self-citation
Metadata
- Authors
- Salvagno, G., Lima-Oliveira, G., Brocco, G., Danese, E., Guidi, G. C., & Lippi, G.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2013-07-12
- Volume
- 51
- Issue
- 12
- Pages
- 2281-2285
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2102889393
- Cited by
- 42
- References
- 3
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The order of draw: myth or science? https://app.cochat.ai/papers/10.1515/cclm-2013-0412
- The paper
- Salvagno, G., Lima-Oliveira, G., Brocco, G., Danese, E., Guidi, G. C., & Lippi, G. (2013). The order of draw: myth or science? Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2013-0412
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.